In order to understand the characteristics of fine particles emitted from coal-fired power plant stacks, it is important to analyze the size distribution and components of particles. In this study, particle size distributions were measured using the ejector-porous tube dilution device and an ELPI system at a stack in a coal-fired power plant. Main elemental components of particles in each size interval were also identified through TEM-EDS analysis for the particles collected in each ELPI stage. Particle size distributions based on number and mass were analyzed with component distributions from 0.006 to 10 μm. The highest number concentration was about 0.01 μm. The main component of the particles consisted of sulfur, which indicated that sulfate aerosols were generated by gas-to-particle conversion of SO2. In a mass size distribution, a mono-modal distribution with a mode diameter of about 2 μm was shown. For the components of PM1.0 (particles less than 1 μm), the abundance order was F > Mg > S > Ca, and however, for the components of PM10 (particles less than 10 μm), it was in the order of Fe > S > Ca > Mg. The elemental components by particle size were confirmed.
Abstract
In order to understand the characteristics of fine particles emitted from coal-fired power plant stacks, it is important to analyze the size distribution and components of particles. In this study, particle size distributions were measured using the ejector-porous tube dilution device and an ELPI system at a stack in a coal-fired power plant. Main elemental components of particles in each size interval were also identified through TEM-EDS analysis for the particles collected in each ELPI stage. Particle size distributions based on number and mass were analyzed with component distributions from 0.006 to 10 μm. The highest number concentration was about 0.01 μm. The main component of the particles consisted of sulfur, which indicated that sulfate aerosols were generated by gas-to-particle conversion of SO2. In a mass size distribution, a mono-modal distribution with a mode diameter of about 2 μm was shown. For the components of PM1.0 (particles less than 1 μm), the abundance order was F > Mg > S > Ca, and however, for the components of PM10 (particles less than 10 μm), it was in the order of Fe > S > Ca > Mg. The elemental components by particle size were confirmed.
참고문헌 (25)
- Coles, D. G., "Chemical Studies of Stack Fly Ash from a Coal-Fired Power Plant", Environmental Science and Technology, 13, pp.455~459 (1979)
- Córdoba, P., "Status of Flue Gas Desulphurisation(FGD)systems from coal-fired power plants : Overview of the physic-chemical control processes of wet limestone FGDs", Fuel, 144, pp.274~286 (2015)
- Forzatti, P., "Present status and perspectives in de-NOx SCR catalysis", Applied Catalysis A : General, 222, pp.221~236 (2001)
- Gladney, E. S., "Composition and size distribution of in-stack particulate material at a coal-fired power plant", Atmospheric Environment, 10, pp.1071~1077 (1976)
- Henry, A. F., "Characterization of fly ash from Israel with reference to its possible utilization", Fuel, 78, pp.215~223 (1999)
- 주재민, "통계적 기법을 활용한 서해안 화력발전소 오염물질 배출에 따른 수도권 지표면 대기오염농도 영향의 분석", 한국지구과학회지, 40(6), pp.549~560 (2019), 한국지구과학회[DOI]
- Kauppinen, E. I., "Coal Combustion Aerosols : A Field Study", Environmental Science and Technology, 24, pp.1811~1818 (1990)
- Kavouras, I. G., "Influence of ambient temperature on the heterogeneity of ambient fine particle chemical composition and disease prevalence", International Journal of Environmental Health Research, 27, pp.27~39 (2017)
- Lee, S., "High-PM10 concentration episodes in Seoul, Korea : Background sources and related meteorological conditions", Atmospheric Environment, 45, pp.7240~7247 (2011)
- López-Vilariño, J. M., "Behavior of fluorine and chlorine in spanish coal fired power plants with pulverized coal boilers and fluidized bed boiler", Environmental Technology, 24, pp.687~692 (2003)
- McElroy, M. W., "Size distribution of fine particles from coal combustion", Science, 215, pp.13~19 (1982)
- Ninomiya, Y., "Influence of coal particle size on particulate matter emission and its chemical species produced during coal combustion", Fuel Processing Technology, 85, pp.1065~1088 (2004)
- 박현수, "연료별 화력발전시설의 미세먼지(PM10 및 PM2.5) 배출특성", 한국대기환경학회지, 34(4), pp.534~541 (2018), 한국대기환경학회[DOI]
- Peng, R. D., "Components of U. S. Fine Particle Air Pollution", Environmental Health Perspectives, 124, pp.957~963 (2009)
- Pudasainee, D., "Oxidation, reemission and mass distribution of mercury in bituminous coal-fired power plants with SCR, CS-ESP and wet FGD", Fuel, 93, pp.312~318 (2012)
- Saarnio, K., "Chemical composition and size of particles in emissions of a coal-fired power plant with flue gas desulfurization", Journal of Aerosol Science, 73, pp.14~26 (2014)
- 신동호, "화력발전소 굴뚝 미세먼지 측정을 위해 개발한 이젝터-다공튜브 희석장치의 희석비 검증", PARTICLE AND AEROSOL RESEARCH, 15(3), pp.105~113 (2019), 한국입자에어로졸학회[DOI]
- Shin, D., "Development of a new dilution system for continuous measurement of particle concentration in the exhaust from a coal-fired power plant", Fuel, 257, pp.116045~ (2019)
- Shin, D., "Continuous measurement of PM10 and PM2. 5 concentration in coal-fired power plant stacks using a newly developed diluter and optical particle counter", Fuel, 269, pp.117445~ (2020)
- Shin, D., "Measurement and Analysis of PM10 and PM2. 5 from Chimneys of Coal-fired Power Plants Using a Light Scattering Method", Aerosol and Air Quality Research, 22, pp.210378~ (2022)
- Xu, M., "Coal combustion-generated aerosols : Formation and properties", Proceedings of the Combustion Institute, 33, pp.1681~1697 (2011)
- Xu, Y., "The role of steam in silica vaporization and ultrafine particulate matter formation during wet oxy-coal combustion", Applied Energy, 133(15), pp.144~151 (2014)
- Yoo, J. I., "Particle-size distributions and heavy metal partitioning in emission gas from different coal-fired power plants", Environmental Engineering Science, 22, pp.272~279 (2005)
- 윤종상, "국내공정시험기준과 ISO 방법을 이용한 고정오염원 미세먼지 (PM10, PM2.5) 측정 방법 및 입경분율 비교 : 석탄화력발전소, 석유정제시설 중심으로", 한국대기환경학회지, 33(4), pp.342~350 (2017), 한국대기환경학회[DOI]
- Zheng, C., "Partitioning of Hazardous Trace Elements among Air Pollution Control Devices in Ultra-Low-Emission Coal-Fired Power Plants", Energy and Fuels, 31, pp.6334~6344 (2017)