Objectives: With the growth of national interest in fine particulate matter, many complaints about pollutants emitted from air pollution emitting facilities have arisen in recent years. In particular, it is thought that a large volume of particulate pollutants are discharged from workplaces that use Solid Refuse Fuel (SRF). Therefore, particulate contaminants generated from SRF were measured and analyzed in this study in terms of respective particle sizes. Methods: In this study, particulate matter in exhaust gas was measured by applying US EPA method 201a using a cyclone. This method measures Filterable Particulate Matter (FPM), and does not consider the Condensable Particulate Matter (CPM) that forms particles in the atmosphere after being discharged as a gas in the exhaust gas. Results: The mass concentration of Total Suspended Particles (TSP) in the four SRF-using facilities was 1.16 to 11.21 mg/Sm3, indicating a very large concentration deviation of about 10 times. When the fuel input method was the continuous injection type, particulate matter larger than 10 µm diameter showed the highest particle size fraction, followed by particulate matter smaller than 10 µm and larger than 2.5 µm, and particulate matter of 2.5 µm or less. Contrary to the continuous injection type, the batch injection type had the smallest particle size fraction of particulate matter larger than 10 µm. The overall particulate matter decreased as the operating load factor decreased from 100% to 60% at the batch input type D plant. In addition, as incomplete combustion significantly decreased, the particle size fraction also changed significantly. Both TSP and heavy metals (six items) satisfied the emissions standards. The measured value of the emission factor was 38-99% smaller than the existing emissions factor. Conclusions: In the batch injection facility, the particulate matter decreased as the operating load factor decreased, as did the particle size fraction of the particulate matter. These results will help the selection of effective methods such as reducing the operating load factor instead of adjusting the operating time during emergency reduction measures.
Abstract
Objectives: With the growth of national interest in fine particulate matter, many complaints about pollutants emitted from air pollution emitting facilities have arisen in recent years. In particular, it is thought that a large volume of particulate pollutants are discharged from workplaces that use Solid Refuse Fuel (SRF). Therefore, particulate contaminants generated from SRF were measured and analyzed in this study in terms of respective particle sizes. Methods: In this study, particulate matter in exhaust gas was measured by applying US EPA method 201a using a cyclone. This method measures Filterable Particulate Matter (FPM), and does not consider the Condensable Particulate Matter (CPM) that forms particles in the atmosphere after being discharged as a gas in the exhaust gas. Results: The mass concentration of Total Suspended Particles (TSP) in the four SRF-using facilities was 1.16 to 11.21 mg/Sm3, indicating a very large concentration deviation of about 10 times. When the fuel input method was the continuous injection type, particulate matter larger than 10 µm diameter showed the highest particle size fraction, followed by particulate matter smaller than 10 µm and larger than 2.5 µm, and particulate matter of 2.5 µm or less. Contrary to the continuous injection type, the batch injection type had the smallest particle size fraction of particulate matter larger than 10 µm. The overall particulate matter decreased as the operating load factor decreased from 100% to 60% at the batch input type D plant. In addition, as incomplete combustion significantly decreased, the particle size fraction also changed significantly. Both TSP and heavy metals (six items) satisfied the emissions standards. The measured value of the emission factor was 38-99% smaller than the existing emissions factor. Conclusions: In the batch injection facility, the particulate matter decreased as the operating load factor decreased, as did the particle size fraction of the particulate matter. These results will help the selection of effective methods such as reducing the operating load factor instead of adjusting the operating time during emergency reduction measures.
참고문헌 (13)
- 김성천, "미세먼지(PM10)와 초미세먼지(PM2.1)의 농도와 폐포 침착율 조사", 한국환경보건학회지, 45(2), pp.126~133 (2019), 한국환경보건학회[DOI]
- 신형순, "포천시 공단지역 미세먼지 중 중금속농도 특성", 한국환경보건학회지, 45(6), pp.577~582 (2019), 한국환경보건학회[DOI]
- World Health Organization (WHO), "Guideline for air quality", ~ (2000)
- 윤단기, "실내·외 실시간 모니터링을 활용한 폼알데하이드 및 미세먼지(PM10, PM2.5)의 거주시간별 노출 및 위해도 평가", 한국환경보건학회지, 45(6), pp.646~657 (2019), 한국환경보건학회[DOI]
- A survey on the people’s consciousness of particulate matter, "Shin DW", Korea Environment Institute, ~, pp.KEI Focus. 45 (2019)
- A study on the management plan for the reduction of the fine particulate matter from solid refuse fuel manufacturing and using facilities, "Kang DE", National Institute of Environmental Research, ~ (2017)
- "Method201a, Determination of PM10And PM2.5 emissions from stationary sources"[URL]
- 박현수, "연료별 화력발전시설의 미세먼지(PM10 및 PM2.5) 배출특성", 한국대기환경학회지, 34(4), pp.534~541 (2018), 한국대기환경학회[DOI]
- 김종현, "고체연료 사용에 따른 오염물질 배출특성 조사연구", 한국대기환경학회지, 33(2), pp.77~86 (2017), 한국대기환경학회[DOI]
- Toxicological review of zinc and compounds, "United States Environmental Protection Agency (U.S EPA)", ~, pp.EPA (2005), 635[DOI]
- 명노일, "신도시 내 소각로 운영에 대한 건강영향평가 사례 연구 - 중금속 흡입에 따른 인체 위해도 평가 -", 환경영향평가, 19(3), pp.271~279 (2010), 한국환경영향평가학회
- 김영하, "소각로 건설사업에 대한 건강영향평가 사례연구 - 중금속 흡입에 따른 인체 위해성 평가 -", 환경영향평가, 18(1), pp.11~19 (2009), 한국환경영향평가학회