광산란법을 이용한 국내 석탄화력발전소 굴뚝에서 배출되는 PM10, PM2.5 측정 및 분석
Measurement and analysis of PM10 and PM2.5 from chimneys of coal-fired power plants using a light scattering method
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Air pollutants emitted from chimneys of coal-fired power plants are considered to be a major source of fine particulate matter in the atmosphere. In order to manage fine particle in the chimney of a coal-fired power plant, it is necessary to know the concentration of fine particle emitted in real time, but the current system is difficult. In this study, a real-time measurement system for chimney fine particle was developed, and measurements were performed on six coal-fired power plants. Through the measurements, the mass concentration distribution according to the particle size could be secured. All six chimneys showed bimodal distribution, and the count median diameters of each mode were 0.5 and 1.1 μm. In addition, it was compared with the gravimetric measurement method, and it was determined that the relative accuracy for PM10 was within 20%, and the value measured using the developed measuring instrument was reliable. Finally, three power plants were continuously measured for one month, and as a result of comparing the concentration of PM10 according to the amount of power generation, it was confirmed that the PM10 discharged from the chimney increased in the form of an exponential function according to the amount of power generation.
Abstract
Air pollutants emitted from chimneys of coal-fired power plants are considered to be a major source of fine particulate matter in the atmosphere. In order to manage fine particle in the chimney of a coal-fired power plant, it is necessary to know the concentration of fine particle emitted in real time, but the current system is difficult. In this study, a real-time measurement system for chimney fine particle was developed, and measurements were performed on six coal-fired power plants. Through the measurements, the mass concentration distribution according to the particle size could be secured. All six chimneys showed bimodal distribution, and the count median diameters of each mode were 0.5 and 1.1 μm. In addition, it was compared with the gravimetric measurement method, and it was determined that the relative accuracy for PM10 was within 20%, and the value measured using the developed measuring instrument was reliable. Finally, three power plants were continuously measured for one month, and as a result of comparing the concentration of PM10 according to the amount of power generation, it was confirmed that the PM10 discharged from the chimney increased in the form of an exponential function according to the amount of power generation.
참고문헌 (23)
- 백세현, "국내 500MW 표준석탄화력 발전소의 친환경 성능개선을 위한 리파워링 방안 연구", 한국연소학회지, 24(4), pp.37~44 (2019), 한국연소학회[DOI]
- Basu, P., "Combustion of coal in circulating fluidized-bed boilers : a review", Chemical Engineering Science, 54, pp.5547~5557 (1999)
- Córdoba, P., "Status of flue gas desulphurisation(FGD)systems from coal-fired power plants : Overview of the physic-chemical control processes of wet limestone FGDs", Fuel, 144, pp.274~286 (2015)
- Fernandes, U., "Particle emissions from a domestic pellets-fired boiler", Fuel Processing Technology, 103, pp.51~56 (2012)
- Goodarzi, F., "Plerosphere and its role in reduction of emitted fine fly ash particles from pulverized coal-fired power plants", Fuel, 88(2), pp.382~386 (2009)
- Groves, J., "A survey of exposure to diesel engine exhaust emissions in the workplace", The Annals of Occupational Hygiene, 44(6), pp.435~447 (2000)
- Higham, D. J., "MATLAB guide", pp.177~ (2016), Society for Industrial and Applied Mathematics
- "ISO 23210, Stationary source emissions determination of PM10", PM2.5 mass concentration in flue gas measurement at low concentrations by use of impactors, 2009
- Kim, H. C., "Synoptic perspectives on pollutant transport patterns observed by satellites over East Asia: Case studies with a conceptual model", Atmospheric Chemistry and Physics Discussions, 1~30 (2016)
- 윤종상, "국내공정시험기준과 ISO 방법을 이용한 고정오염원 미세먼지 (PM10, PM2.5) 측정 방법 및 입경분율 비교 : 석탄화력발전소, 석유정제시설 중심으로", 한국대기환경학회지, 33(4), pp.342~350 (2017), 한국대기환경학회[DOI]
- Lee, H., "5 Power Generation Companies, “We will reduce fine dust with the best possible”: Suspension of coal-fired power plants and promotion of upper limit restrictions… Reduction of 2,108 tons of fine dust emissions compared to the previous year_5 power generation companies, investment in eco-friendly facilities and promotion of indoor storage of outdoor storage facilities", Journal of Electrical World Monthly Magazine, 5, pp.38~40 (2020)
- Lee, S., "High-PM10 concentration episodes in Seoul, Korea: Background sources and related meteorological conditions", Atmospheric Environment, 45(39), pp.7240~7247 (2011)
- Lewis, T. R., "A chronic inhalation toxicity study of diesel engine emissions and coal dust, alone and combined", Journal of the American College of Toxicology, 8(2), pp.345~375 (1989)
- Nobuhiro, M., "Radiative transfer modeling of filter-based measurements of light absorption by particles : Importance of particle size dependent penetration depth", Journal of Aerosol Science, 41(4), pp.401~412 (2010)
- 박현수, "연료별 화력발전시설의 미세먼지(PM10 및 PM2.5) 배출특성", 한국대기환경학회지, 34(4), pp.534~541 (2018), 한국대기환경학회[DOI]
- Richard, D., "Isokientic sampling probes", Industrial and Engineering Chemistry, 49(2), pp.294~302 (1957)
- Meij, R., "The emissions and environmental impact of PM10 and trace elements from a modern coal-fired power plant equipped with ESP and wet FGD", Fuel Processing Technology, 85, pp.641~656 (2004)
- Ministry of Environment, "Particulate matter-automated measuring method in flue gas", Air Pollution Process Test Standard, ES01810.1a, ~ (2011)
- Shin, D., "Development of a new dilution system for continuous measurement of particle concentration in the exhaust from a coal-fired power plant", Fuel, 257, pp.116045~ (2019)
- Shin, D., "Continuous measurement of PM10 and PM2.5 concentration in coal-fired power plant stacks using a newly developed diluter and optical particle counter", Fuel, 269, pp.117445~ (2020)
- Stolle, R., "Oxidation and reduction of mercury by SCR DeNOx catalysts under flue gas conditions in coal fired power plants", Applied Catalysis B : Environmental, 144, pp.486~497 (2014)
- Air quality for particulate matter, "U.S. Environmental Protection Agency (USEPA)", National Center for Environmental Assessment, Office of Research and Development, ~, pp.EPA (1996), 600[DOI]
- Wada, M., "A two-stage virtual impactor for in-stack sampling of PM2. 5 and PM10 in flue gas of stationary sources", Aerosol and Air Quality Research, 16, pp.36~45 (2016)