다리 환자를 위한 보행보조로봇의 종아리 링크 3축 힘센서 개발
Development of Calf Link Force Sensors of Walking Assist Robot for Leg Patients
0
조회
0
다운로드
11
인용
0
참고문헌
키워드
초록
This paper describes the design and fabrication of a three-axis force sensor with parallel plate beams (PPSs) for measuring the calf force while a patient with a walking assist robot is walking. Current walking assist robots can’t measure the weight of the patient’s legand the robot’s leg which required for robot control. So, the three-axis force sensor in the calf link is designed and manufactured, it iscomposed of a Fx force sensor, a Fy force sensor and a Fz force sensor. The three-axis force sensor was designed using by FEM(FiniteElement Method), and fabricated using strain-gages. The characteristics experiment of the three-axis force sensor was carried out respec-tively. The test results indicated that the repeatability error and the non-linearity error of three-axis force sensor was less than 0.04% respectively. Therefore, the fabricated three-axis force sensor in the calf link can be used to measure the patient’s calf force in the walking assist robot.
Abstract
This paper describes the design and fabrication of a three-axis force sensor with parallel plate beams (PPSs) for measuring the calf force while a patient with a walking assist robot is walking. Current walking assist robots can’t measure the weight of the patient’s legand the robot’s leg which required for robot control. So, the three-axis force sensor in the calf link is designed and manufactured, it iscomposed of a Fx force sensor, a Fy force sensor and a Fz force sensor. The three-axis force sensor was designed using by FEM(FiniteElement Method), and fabricated using strain-gages. The characteristics experiment of the three-axis force sensor was carried out respec-tively. The test results indicated that the repeatability error and the non-linearity error of three-axis force sensor was less than 0.04% respectively. Therefore, the fabricated three-axis force sensor in the calf link can be used to measure the patient’s calf force in the walking assist robot.
참고문헌 (12)
- M. Wu, "A cable-driven locomotor training system for restoration of gait in human SCI", Gait & Posture, (33), pp.256~260 (2011)
- M. M. Martins, "Assistive mobility devices focusing on Smart Walkers:Classification and review", Robotics and Autonomous Systems, (60), pp.548~562 (2012)
- N. Karavas, "Tele-impedance based assistive control for a compliant knee exoskeleton", Robotics and Autonomous Systems, 73, pp.78~90 (2015)
- J. F. Zhang, "5-Link model based gait trajrctory adaption control strategies of the gait rehabilitation exoskeleton for poststroke patients", Mechatronics, 20(3), pp.368~376 (2010)
- V. Rajasekaran, "An adaptive control strategy for postural stability using a wearable robot", Robotics and Autonomous Systems, 73, pp.16~23 (2015)
- A. Pennycott, "Estimation and volitional feedback control of active work rate during robot-assisted gait", Control Engineering Pracrice, (17), pp.322~328 (2009)
- S. A. Liu, "A novel six-component force sensor of good measurement isotropy and sensitivities", Sensors and Actuators A, 100, pp.223~230 (2002)
- 김한솔, "고관절 재활로봇의 2축 힘", 토크센서 설계, 2016, pp.22(7), 524~529[DOI]
- A. Song, "A novel self-decoupled four degree-of-freedom wrist force", torque nsor, 2007, pp.40, 883~891
- 정재현, "무릎재활을 위한 재활로봇용 힘센서 설계", 제어.로봇.시스템학회 논문지, 23(1), pp.46~52 (2017), 제어·로봇·시스템학회[DOI]
- torque sensor, "Multi-axis forcre", pp.2014, ATI Industrial Automation
- 김갑순, "다축 힘", 모멘트 센서 교정기의 개발 및 그의 불확도 평가, 2007, pp.24(10), 91~98[DOI]
