In this paper, a torque sensor is designed and fabricated to measure the knee joint torque of a walking assist robot for stroke patients. The torque sensor sensing part was modeled on the link of the part connected to the knee joint motor. The torque capacity of the knee joint was calculated by simulation and the size of the torque sensor sensing part was designed using the finite element method. Thetorque sensor was fabricated by attaching a strain gauge to the sensing part. Characteristic experiments were conducted to characterizethe torque sensor, and the torque sensor was calibrated to utilize it for the control of the walking assist robot. As a result of the char-acteristics test, the reproducibility error and the nonlinearity error of the torque sensor were 0.03% and 0.04%, respectively. Therefore, it is considered that the developed torque sensor can be used to measure the torque applied to the knee joint when walking on a walking assist robot.
Abstract
In this paper, a torque sensor is designed and fabricated to measure the knee joint torque of a walking assist robot for stroke patients. The torque sensor sensing part was modeled on the link of the part connected to the knee joint motor. The torque capacity of the knee joint was calculated by simulation and the size of the torque sensor sensing part was designed using the finite element method. Thetorque sensor was fabricated by attaching a strain gauge to the sensing part. Characteristic experiments were conducted to characterizethe torque sensor, and the torque sensor was calibrated to utilize it for the control of the walking assist robot. As a result of the char-acteristics test, the reproducibility error and the nonlinearity error of the torque sensor were 0.03% and 0.04%, respectively. Therefore, it is considered that the developed torque sensor can be used to measure the torque applied to the knee joint when walking on a walking assist robot.
참고문헌 (19)
- M. Wu, "A Cable-driven Locomotor Training System for Restoration of Gait in Human SCI", Gait & Posture, (33), pp.256~260 (2011)
- M.M. Martins, "Assistive Mobility Devices Focusing on Smart Walkers: Classification and review", Robotics and Autonomous Systems, (60), pp.548~562 (2012)
- T. Wanga, "Walking analysis of young and elderly people by using an intelligent walker ANG", Robotics and Autonomous Systems, 75, pp.96~106 (2016)[DOI]
- H. Terada, "Developments of a Knee Motion Assist Mechanism for Wearable Robot with a Non-circular Gear and Grooved Cams", Mechanisms, Transmissions and Applica, 3, pp.69~76 (2011)
- S. Kubota, "Feasibility of Rehabilitation Training With a Newly Developed Wearable Robot for Patients With Limited Mobility", Archives of Physical Medicine and Rehabilitation, 94, pp.1080~1087 (2013)[DOI]
- M. Aach, "Voluntary driven exoskeleton as a new tool for rehabilitation in chronic spinal cord injury: a pilot study", The Spine Journal, 14, pp.2847~2853 (2014)[DOI]
- H. Watanabe, "Locomotion Improvement Using a Hybrid Assistive Limb in Recovery Phase Stroke Patients: A Randomized Controlled Pilot Study", Archives of Physical Medicine and Rehabilitation, 95, pp.2006~2012 (2014)[DOI]
- N. Karavas, "Tele-impedance based assistive control for a compliant knee exoskeleton", Robotics and Autonomous Systems, 73, pp.78~90 (2015)[DOI]
- J.F. Zhang, "5-Link model based gait trajrctory adaption control strategies of the gait rehabilitation exoskeleton for poststroke patients", Mechatronics, 20(3), pp.368~376 (2010)[DOI]
- V. Rajasekaran, "An adaptive control strategy for postural stability using a wearable robot", Robotics and Autonomous Systems, 73, pp.16~23 (2015)[DOI]
- A. Pennycott, "Estimation and volitional feedback control of active work rate during robot-assisted gait", Control Engineering Pracrice, (17), pp.322~328 (2009)
- S. A. Liu, "A novel six-component force sensor of good measurement isotropy and sensitivities", Sensors and Actuators A, 100, pp.223~230 (2002)[DOI]
- 김한솔, "고관절 재활로봇의 2축 힘", 토크센서 설계, 2016, pp.22(7), 524~529[DOI]
- A. Song, "A novel selfdecoupled four degree-of-freedom wrist force", torque sensor, 2007, pp.40, 883~891
- 정재현, "무릎재활을 위한 재활로봇용 힘센서 설계", 제어.로봇.시스템학회 논문지, 23(1), pp.46~52 (2017), 제어·로봇·시스템학회[DOI]
- ATI Industrial Automation, "Multi-axis forcre", torque sensor, 2014, 4~45
- 김한솔, "다리 환자를 위한 보행보조로봇의 종아리 링크 3축 힘센서 개발", 센서학회지, 26(2), pp.114~121 (2017), 한국센서학회[DOI]
- 정재현, "착용용 보행로봇의 허벅지 힘측정을 위한 힘센서 설계", 한국정밀공학회지, 34(10), pp.707~713 (2017), 한국정밀공학회
- 김갑순, "다축 힘", 모멘트 센서 교정기의 개발 및 그의 불확도 평가, 2007, pp.24(10), 91~98[DOI]