본문 바로가기
KERD
논문KCI 등재

손목굽힘운동 재활로봇을 위한 3축 힘센서 설계

Design of a Three-Axis Force Sensor for Wrist Bending-Exercise Rehabilitation Robot

2

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류공학일반

초록

Most serious stroke patients have the paralysis of their wrists, and can't use of their hands freely. But their wrists can be recovered by rehabilitation exercise. Recently, professional rehabilitation therapeutists exercise the wrists of stroke patients in hospital. But the wrists of stroke patients have not rehabilitated, because the therapeutists are much less than stroke patients in number. Therefore, the wrist bendingexercise rehabilitation robot that can measure the bending force of the patients' wrists is developed. In this paper, the three-axis force sensor was designed for the wrist bending-exercise rehabilitation robot. As a test results, the interference error of the three-axis force sensor was less than 0.85%. It is thought that the sensor can be used to measure the wrist bending force of the patient.

Abstract

Most serious stroke patients have the paralysis of their wrists, and can't use of their hands freely. But their wrists can be recovered by rehabilitation exercise. Recently, professional rehabilitation therapeutists exercise the wrists of stroke patients in hospital. But the wrists of stroke patients have not rehabilitated, because the therapeutists are much less than stroke patients in number. Therefore, the wrist bendingexercise rehabilitation robot that can measure the bending force of the patients' wrists is developed. In this paper, the three-axis force sensor was designed for the wrist bending-exercise rehabilitation robot. As a test results, the interference error of the three-axis force sensor was less than 0.85%. It is thought that the sensor can be used to measure the wrist bending force of the patient.

참고문헌 (10)

  1. M. H. Rahman, "Modeling and development of an exoskeleton robot for rehabilitation of wrist movements", 2010 IEEE, 2010, 25~30
  2. B. C. Tsai, "An articulated rehabilitation robot for upper limb physiotherapy and training", 2010 IEEE, 2010, 1470~1475
  3. S. Liu, "Interactive control for the arm rehabilitation robot", 2009 International Workshop on Intelligent Systems and Applications (ISA 2009), pp.1~4 (2009)
  4. W. Huo, "Control of upper-limb power-assist exoskeleton based on motion intention recognition", IEEE International Conference on Robotics and Automation, pp.2243~2248 (2011)
  5. A. Umemura, "A study on power-assisted rehabilitation robot arms operated by patient with upper limb disabilities", 2009 IEEE International Conference on Rehabilitation Robotics (ICORR 2009), pp.451~456 (2009)
  6. Y. Ren, "Developing a whole-arm exoskeleton robot with hand opening and closing mechanism for upper limb stroke rehabilitation", 2009 IEEE International Conference on Rehabilitation Robotics (ICORR 2009), pp.761~765 (2009)
  7. K. Nagai, "Development of a small six-component force", torque sensor based on the double-cross structure, 2004, pp.22(3), 361~369
  8. G. S. Kim, "Development of the 6-axis force", moment sensor for an intelligent robot's gripper, 2005, pp.118, 127~134
  9. ATI Industrial Automation, "Multi-axis forcre", torque sensor, 2005, pp.4~45
  10. G. S. Kim, "Development of calibration system for multi-axis force", moment sensor and its uncertainty evaluation, 2007, pp.24(10), 91~98

관련 논문AI추천

이 간행물의 다른 논문 (12건)