본문 바로가기
KERD
논문KCI 등재

압축기 회전수 변화에 따른 R134a/R1234yf 혼합냉매를 적용한 자동차 공조 시스템의 성능 특성에 대한 해석적 연구

Analytical Study on the Performance Characteristics of Automobile Air-Conditioning System Using the Mixed Refrigerant R134a/R1234yf for Varying Compressor Rotation Speeds

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류과학기술학

초록

This study presents the performance analysis for an automobile air-conditioning system using the mixed refrigerant R134a/R1234yf with varying compressor rotation speeds. Accordingly, the compressor, condenser, expansion device, and evaporator of the automobile air-conditioning system were designed using the EES program, and the cooling capacity and COP of the automobile air-conditioning system using the mixed refrigerant were comparatively analyzed for simulated data. The cooling capacity using the mixed R134a/R1234yf(30%) system at a compressor rotation speed of 2500 rpm was about 6.13% lower than that using the R134a system alone. Moreover, the COP using the mixed R134a/R1234yf(30%) system at a compressor rotation speed of 2500 rpm was about 7.45% lower than that using the R134a system alone. The use of the R134a /R1234yf mixed refrigerant can thus reduce global warming potential; further, as there is no significant difference in performance compared with the system using only R134a, the applicability of the mixed R134a/R1234yf refrigerant is confirmed.

Abstract

This study presents the performance analysis for an automobile air-conditioning system using the mixed refrigerant R134a/R1234yf with varying compressor rotation speeds. Accordingly, the compressor, condenser, expansion device, and evaporator of the automobile air-conditioning system were designed using the EES program, and the cooling capacity and COP of the automobile air-conditioning system using the mixed refrigerant were comparatively analyzed for simulated data. The cooling capacity using the mixed R134a/R1234yf(30%) system at a compressor rotation speed of 2500 rpm was about 6.13% lower than that using the R134a system alone. Moreover, the COP using the mixed R134a/R1234yf(30%) system at a compressor rotation speed of 2500 rpm was about 7.45% lower than that using the R134a system alone. The use of the R134a /R1234yf mixed refrigerant can thus reduce global warming potential; further, as there is no significant difference in performance compared with the system using only R134a, the applicability of the mixed R134a/R1234yf refrigerant is confirmed.

참고문헌 (14)

  1. Sethi, A., "Low GWP R134a replacements for small refrigeration (plug-in) applications", Int. J. Refrig., 66(06), pp.64~72 (2016)
  2. Mota-Babiloni, A., "Drop-in energy performance evaluation of R1234yf and R1234ze(E) in a vapor compression system as R134a replacements", Applied Thermal Engineering, 71(1), pp.259~265 (2014)
  3. Ajay Kumar Yadav, "Performance Analysis of Refrigerants R1234yf, R1234ze and R134a in Ejector-Based Refrigeration Cycle", International Journal of Air-Conditioning and Refrigeration, 26(3), pp.1~7 (2018), 대한설비공학회
  4. Jignesh, K, V., "Comparative Evaluation of an Automobile Air-Conditioning System Using R134a and Its Alternative Refrigerants", Energy Procedia, 109(3), pp.153~160 (2017)
  5. Pottker, G., "Experimental investigation of the effect of condenser subcooling in R134a and R1234yf air-conditioning systems with and without internal heat exchanger", Int. J . Refrig., 50(2), pp.104~113 (2015)
  6. "Todayenergy"[URL]
  7. Steven Brown, J., "Comparative analysis of an automotive air conditioning system operating with CO2 and R134a", Int. J. Refrig., 25(1), pp.19~32 (2002)
  8. Chi, J., "A computer Model HTPUMP for Simulation of Heat Pump Steady state Performance" (1979), NBS
  9. EVSIM: An Evaporator Simulation Model Accounting for Refrigerant and One Dimensional Air Distribution, "Domanski, P. A.", NIST, ~, pp.NISTIR 89-4133 (1989)
  10. Dittus F. W., "Public Eng. 2" (1930), University of California
  11. Pierre B., "Flow resistance with boiling refrigerants-part1", ASHRAE Journal, pp.58~65 (1964)
  12. Gungor, K. E., "A general correlation for boiling in tubes and annuli", Int. J. Heat Mass Transf., 19, pp.351~358 (1986)
  13. Wang C. C., "Heat transfer and friction characteristics of plain fin-and-tube heat exchanger, part II:Correlation", Int. J. Heat Mass Transf., 43, pp.2693~2700 (2000)
  14. Choi Jongmin, "A generalized correlation for tw o-phase flow of alternative refrigerants through short tube orifices", Int. J. Refrig., 27, pp.393~400 (2004)

관련 논문AI추천

이 간행물의 다른 논문 (10건)