무착상 조건에서 R404A, R134a, R744를 적용한 냉동탑차용 냉장시스템의 성능변화 비교

Comparison of Cooling Performance in a R404A, R134a, and R744 Refrigeration Truck Under Non-Frost Condition

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류공학일반

초록

An automotive air-conditioning system and refrigeration truck are normally used refrigeration R134a and R404A, respectively. In this study, the theoretical study on the performance of R744, R134a, and R404A refrigeration system for the refrigeration truck was carried out for varied operating conditions. As a result, the refrigeration capacity of all system was designed with 2.5 kW at the standard conditions, and the COP of R134a system was the highest. The performance of all systems with the outdoor temperature rapidly decreased. In addition, when outdoor air velocity varied from 1 to 2 m/s, the performance improvement was noticeable, but it didn't increase anymore when outdoor air velocity exceeded 4 m/s due to a decrease in the effectiveness of the heat exchanger. As compressor RPM increased, the performance reduced most for R134a system. The R134a system showed the smallest change in performance with changing in operating conditions.

Abstract

An automotive air-conditioning system and refrigeration truck are normally used refrigeration R134a and R404A, respectively. In this study, the theoretical study on the performance of R744, R134a, and R404A refrigeration system for the refrigeration truck was carried out for varied operating conditions. As a result, the refrigeration capacity of all system was designed with 2.5 kW at the standard conditions, and the COP of R134a system was the highest. The performance of all systems with the outdoor temperature rapidly decreased. In addition, when outdoor air velocity varied from 1 to 2 m/s, the performance improvement was noticeable, but it didn't increase anymore when outdoor air velocity exceeded 4 m/s due to a decrease in the effectiveness of the heat exchanger. As compressor RPM increased, the performance reduced most for R134a system. The R134a system showed the smallest change in performance with changing in operating conditions.

참고문헌 (21)

  1. Mun, J. C., "Cooling Characteristics of Refrigerated Vehicles with Heat Storage Materials in Thermobank", Summer Conference Proceedings of SAREK, pp.810~814 (2009)
  2. Peck, J. H., "Study on the Performance Characteristics of Mechanical Refrigeration Truck vs. Hold-Over Refrigeration Truck", SAREK Conference, pp.339~344 (2002)
  3. Kim, S. H., "Performance Comparison between R404A and R744 Refrigeration System in Refrigerating Conditions", SAREK Conference, pp.199~202 (2012)
  4. Changqing, T., "A mathematical model of variable displacement swash plate compressor for automotive air conditioning system", International Journal of Refrigeration, 29, pp.270~280 (2006)
  5. Steven Brown, J., "Comparative analysis of an automotive air conditioning system operating with CO2 and R134a, International of Refrigeration", 25, Issue 1, 1, pp.19~32 (2002)
  6. Sanchez, D., "Influence of the Superheat Associated to a Semi-hermetic Compressor of a Transcritical CO2Refrigeration Plant", Applied Thermal Engineering, 30(4), pp.302~309 (2010)
  7. Chi, J., "A computer Model HTPUMP for Simulation of Heat Pump Steady state Performance", NBS, ~ (1979)
  8. EVSIM: An Evaporator Simulation Model Accounting for Refrigerant and One Dimensional Air Distribution, "Domanski, P. A.", NIST, ~, pp.NISTIR 89-4133 (1989)
  9. Wang, C. C., "Comparative Study of Compact Enhanced Fin-and-Tube Heat Exchangers", Heat and Mass Transfer, 44, pp.3565~3573 (2001)
  10. 강태형, "무착상 조건에서 나선형 핀-튜브 증발기의 성능에 대한 실험 및 해석적 연구", 석사, 기계공학, pp.2010
  11. Traviss, D. P., "Force convection condensation inside tube : a heat transfer equation for condenser design", ASHRAE Transactions, 79, pp.157~165 (1972)
  12. Friedel L., "Improved friction pressure drop correlation for horizontal and vertical two-phase pipe flow", European two-phase flow group meeting, pp.E2~ (1979)
  13. Dittus F. W., "Public Eng. 2" (1930), University of California
  14. Pierre B., "Flow resistance with boiling refrigerants-part1", ASHRAE Journal, pp.58~65 (1964)
  15. Gungor, K. E., "A general correlation for boiling in tubes and annuli", International Journal of Heat Transfer, 19, pp.351~358 (1986)
  16. Gnielinski, V., "New Equation for Heat and Mass Transfer in Turbulent Pipe and Channel Flow", Int. J. Chemical Engineering, 16, pp.359~368 (1976)
  17. Yoon, S. H., "Characteristics of Evaporative Heat Transfer and Pressure Drop of Carbon Dioxide and Correlation Development Near the Critical Point", Proceedings of the SAREK, 16(6), pp.530~534 (2004)
  18. Churchill, S., "Friction Factor Equation Spans all Fluid Flow Regimes", Journal of Chemical Engineering, 7(24), pp.91~92 (1997)
  19. Wang C. C., "Heat transfer and friction characteristics of plain fin-and-tube heat exchanger, part II:Correlation", International Journal of Heat and Mass Transfer, 43(15), pp.2693~2700 (2000)
  20. Hwang, Y. W., "Experimental Study on the CO2 Flow through Electronic Expansion Valves", 2007 Summer Annual Conference of SAPEK, pp.1237~1241 (2007)
  21. Choi J. M., "A generalized correlation for two-phase flow of alternation refrigerants through short tube orifices", International Journal of Refrigeration, 27(4), pp.393~400 (2004)

관련 논문AI추천

이 간행물의 다른 논문 (8건)