R134a와 R1234yf 냉매 적용에 따른 냉동탑차 냉장시스템의 성능비교

Performance Comparison of a Refrigeration System in the Refrigeration Truck Using R134a and R1234yf

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류공학일반

초록

Recently, the importance of delivery system has being developed according to the growth of online and mobile shopping market. Especially, transportation of frozen food by online and home shopping is increasing significantly. Therefore, the demand of refrigeration truck is also increasing. In this study, performance characteristics of refrigeration system using R134a and R1234yf in a refrigeration truck were compared by experimental method. When the refrigerant charging amounts increased from 1.1 to 1.4 kg, COP of R134a system was increased and the maximum COP was 2.63 at the charge amount of 1.4 kg. And that of R1234yf system was 2.49 at the optimal charge amount of 1.3 kg. The optimal EEV opening of R134a and R1234yf system was 60% and 50%, respectively. Besides, the COP was 2.69 and 2.49 for R134a and R1234yf at the optimal EEV opening. When the outdoor air temperature increased from 25℃ to 35℃, the system COP of R134a and R1234yf decreased by 15.0% and 11.6%, respectively. Besides, When the compressor rotating speed increased from 1000 to 2000 rpm, the system COP of R134a and R1234yf decreased by 37.5% and 35.9%, respectively. The R134a system showed a higher performance than R1234yf system, but the R134a system showed the larger reduction in the performance according to compressor rotating speed.

Abstract

Recently, the importance of delivery system has being developed according to the growth of online and mobile shopping market. Especially, transportation of frozen food by online and home shopping is increasing significantly. Therefore, the demand of refrigeration truck is also increasing. In this study, performance characteristics of refrigeration system using R134a and R1234yf in a refrigeration truck were compared by experimental method. When the refrigerant charging amounts increased from 1.1 to 1.4 kg, COP of R134a system was increased and the maximum COP was 2.63 at the charge amount of 1.4 kg. And that of R1234yf system was 2.49 at the optimal charge amount of 1.3 kg. The optimal EEV opening of R134a and R1234yf system was 60% and 50%, respectively. Besides, the COP was 2.69 and 2.49 for R134a and R1234yf at the optimal EEV opening. When the outdoor air temperature increased from 25℃ to 35℃, the system COP of R134a and R1234yf decreased by 15.0% and 11.6%, respectively. Besides, When the compressor rotating speed increased from 1000 to 2000 rpm, the system COP of R134a and R1234yf decreased by 37.5% and 35.9%, respectively. The R134a system showed a higher performance than R1234yf system, but the R134a system showed the larger reduction in the performance according to compressor rotating speed.

참고문헌 (12)

  1. Lee, J. G., , Autech Equity Research, 067170, pp.5~ (2016)
  2. Won, J. P., "UNFCCC Alternative Refrigerant Automotive Air-conditioning System Technology Trends", Magazine of the SAREK, 39(2), pp.10~16 (2010)
  3. 조홍현, "대체냉매 R1234yf를 적용한 자동차용 에어컨 시스템의 성능 향상에 관한 연구", 설비공학 논문집, 25(4), pp.201~207 (2013), 대한설비공학회[DOI]
  4. Park, K. J., "Condensation heat transfer, coefficients of R1234yf on plain, low fin, and turbo-C tubes", International journal of refrigeration, 34(1), pp.317~321 (2011)
  5. Sánchez, D., "Energy performance evaluation of R1234yf, R1234ze(E), R600a, R152a as low-GWP R134a alternatives", International Journal of Refrigeration, 74, pp.267~280 (2017)
  6. Shapiro, D., "Drop-in testing of next-generation R134a alternates in a commercial bottle cooler", freezer, 2012, ~
  7. Dang, Y., "Liquid viscosity of low-GWP refrigerant mixtures(R32+R1234yf) and R125+R1234yf)", The Journal of Chemical Thermodynamics, 89, pp.183~188 (2015)
  8. Janković, Z., "Thermodynamic and heat transfer analyses for R1234yf and R1234ze(E) as drop-in replacements for R134a in a small power refrigerating system", 80(5), pp.42~54 (2015)
  9. Zilio, C., "The refrigerant R1234yf in air conditioning systems", Energy, 36(10), pp.6110~6120 (2011)
  10. Zilio, C., "Simulation of R-1234yf performance in a typical automotive system", 3rd IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants (2009)
  11. Minor, B., "HFO-1234yf low GWP refrigerant update", Proceedings of International Refrigeration and Air Conditioning Conference at Purdue, 2349, pp.1~8 (2008)
  12. Lee, H. S., "An Experimental Study on Alternative Refrigerant's Drop-In Performance of Mobile Air Conditioning System", The Korean Society Of Automotive Engineers, (11), pp.1027~1032 (2010)

관련 논문AI추천