본문 바로가기
KERD
논문KCI 등재

Treatment Effects of Maxillary Molar Distalization with Palatal Plate: CBCT Synthesized Cephalometric Analysis

3

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

The purpose of this study was to evaluate the clinical treatment effects of molar distalization with palatal plate using 2 dimensional (2D) cephalograms converted from CBCT. This retrospective clinical study included 20 consecutively treated patients (11 male, 9 female), with an average age of 15±3 years. Cephalometric analysis was made on 2D cephalogram images derived from 3D CBCT. Skeletal, dental, and soft tissue measurements were evaluated. Through the use of palatal plate, clinically successful distalization of maxillary molars was achieved. Statistically significant changes in molars positions were observed between T1 and T2 (before and after the distal movement). The first molar and second premolar distalization were 3.98±1.23 mm and 1.17±3.54 mm with distal tipping of 3.17±4.97°and 3.21±2.86°, respectively. Moreover, the incisors were retracted 3.12±3.24 mm, with 10.31±4.98°of tipping and 1.75±1.54 mm of extrusion. All skeletal changes during treatment were not significant. The upper and lower lips were retracted 1.57 and 1.49 mm respectively. The palatal plate could be a valid clinical option for efficient distalization of the maxillary first molars in Class II patients.

Abstract

The purpose of this study was to evaluate the clinical treatment effects of molar distalization with palatal plate using 2 dimensional (2D) cephalograms converted from CBCT. This retrospective clinical study included 20 consecutively treated patients (11 male, 9 female), with an average age of 15±3 years. Cephalometric analysis was made on 2D cephalogram images derived from 3D CBCT. Skeletal, dental, and soft tissue measurements were evaluated. Through the use of palatal plate, clinically successful distalization of maxillary molars was achieved. Statistically significant changes in molars positions were observed between T1 and T2 (before and after the distal movement). The first molar and second premolar distalization were 3.98±1.23 mm and 1.17±3.54 mm with distal tipping of 3.17±4.97°and 3.21±2.86°, respectively. Moreover, the incisors were retracted 3.12±3.24 mm, with 10.31±4.98°of tipping and 1.75±1.54 mm of extrusion. All skeletal changes during treatment were not significant. The upper and lower lips were retracted 1.57 and 1.49 mm respectively. The palatal plate could be a valid clinical option for efficient distalization of the maxillary first molars in Class II patients.

참고문헌 (29)

  1. Melsen B, "A rational approach to orthodontic anchorage", Prog Orthod, 1, pp.10~22 (1999)
  2. Bolla E, "Evaluation of maxillary molar distalization with the distal jet: a comparison with other contemporary methods", Angle Orthod, 72, pp.481~494 (2002)
  3. Kinzinger GS, "Efficiency of a pendulum appliance for molar distalization related to second and third molar eruption stage", Am J Orthod Dentofacial Orthop, 125, pp.8~23 (2004)
  4. Byloff FK, "Distal molar movement using the pendulum appliance. Part 1: clinical and radiological evaluation", Angle Orthod, 67, pp.249~260 (1997)
  5. Bussick TJ, "Dentoalveolar and skeletal changes associated with the pendulum appliance", Am J Orthod Dentofacial Orthop, 117, pp.333~343 (2000)
  6. Scuzzo G, "Maxillary molar distalization with a modified pendulum appliance", J Clin Orthod, 33, pp.645~650 (1999)
  7. Wong AM, "The use of pendulum appliance inthe treatment of Class II malocclusion", Br Dent J, 187, pp.367~370 (1999)
  8. Ghosh J, "Evaluation of an intraoral maxillary molar distalization technique", Am J Orthod Dentofacial Orthop, 110, pp.639~646 (1996)
  9. Byloff FK, "Distal molar movement using the pendulum appliance. Part 1: clinical and radiological evaluation", Angle Orthod, 67, pp.249~260 (1997)
  10. Byloff FK, "Distal molar movement using the pendulum appliance. Part 2: the effects of maxillary molar root uprighting bends", Angle Orthod, 67, pp.261~270 (1997)
  11. Bussick TJ, "Dentoalveolar and skeletal changes associated with the pendulum appliance", Am J Orthod Dentofacial Orthop, 117, pp.333~343 (2000)
  12. Chiu PP, "A comparison of two intraoral molar distalization appliances: distal jet versus pendulum", Am J Orthod Dentofacial Orthop, 128, pp.353~365 (2005)
  13. Kinzinger GSM, "Efficiency of a pendulum appliance for molar distalization related to second and third molar eruption stage", Am J Orthod Dentofacial Orthop, 125, pp.8~23 (2004)
  14. Kinzinger GSM, "Molar distalization with a modified pendulum appliance in vitro analysis of the force systems and in vivo study in children and adolescents", Angle Orthod, 75, pp.558~567 (2005)
  15. Graber TM, "Orthodontics:current principles and techniques" (2005), Elsevier
  16. Kyung SH, "Distalization of maxillary molars with a midpalatal miniscrew", J Clin Orthod, 37, pp.22~26 (2003)
  17. Chung KR, "The miniplate with tube for skeletal anchorage", J Clin Orthod, 36, pp.407~412 (2002)
  18. Kook YA, "A Modified palatal anchorage plate for simple and efficient distalization", J Clin Orthod, 44, pp.719~730 (2010)
  19. Bruno FG, "Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans", Angle Orthod, 81, pp.26~25 (2011)
  20. Kumar V, "In vivo comparison of conventional and cone beam CT synthesized cephalograms", Angle Orthod, 78, pp.873~879 (2008)
  21. Lamichane M, "Accuracy of reconstructed images from cone-beam computed tomography scans", Am J Orthod Dentofacial Orthop, 136, pp.156~ (2009)
  22. Yu IJ, "Comparison of tooth displacement between buccal mini-implants and palatal plate anchorage for molar distalization: a finite element study", European J Ortho (2011)
  23. Escobar SA, "Distalization of maxillary molars with the bonesupported pendulum: a clinical study", Am J Orthod Dentofacial Orthop, 131, pp.545~549 (2007)
  24. Óncag′′ G, "Osseointegrated implants with pendulum springs for maxillary molar distalization:a cephalometric study", Am J Orthod Dentofacial Orthop, 131, pp.16~26 (2007)
  25. Gelgor IE, "Intraosseous screw-supported upper molar distalization", Angle Orthod, 74, pp.836~848 (2004)
  26. Keles A, "Bodily distalization of molars with absolute anchorage", Angle Orthod, 73, pp.471~482 (2003)
  27. Kircelli BH, "Maxillary molar distaization with a bone-anchoraged pendulum appliance", Angle Orthod, 76, pp.650~659 (2005)
  28. Vandana K, "In vivo comparison of conventional and cone beam CT synthesized cephalograms", Angle Orthod, 78, pp.873~879 (2008)
  29. Natalia Z, "Cephalometric measurements from 3D reconstructed images compared with conventional 2D images", Angle Orthod, 81, pp.856~864 (2011)

관련 논문AI추천

Comparison of treatment effects between four premolar extraction and total arch distalization using the modified C-palatal plate국윤아, 임희진, 조성윤, 한성호, Justyn Park, Mohamed Bayome대한치과교정학회 · 대한치과교정학회지2018 · 제48권 제4호Comparison of treatment effects between the modified C-palatal plate and cervical pull headgear for total arch distalization in adults국윤아, 박영석, 박재현, 박종욱, 한성호, Mohamed Bayome, Noor Laith Sa’aed대한치과교정학회 · 대한치과교정학회지2017 · 제47권 제6호Cone-beam computed tomography-guided threedimensional evaluation of treatment effectiveness of the Frog applianceMujia Li, Xianglin Li, Xiaoxia Su, Xinqin Si, Yang Li대한치과교정학회 · 대한치과교정학회지2019 · 제49권 제3호Treatment effects of mandibular total arch distalization using a ramal plate국윤아, 김윤지, 김창현, Jae Hyun Park, Jonghan Yu, Mohamed Bayome, Sungkon Kim대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제4호A reliable method for evaluating upper molar distalization: Superimposition of three-dimensional digital modelsAli Altug Bicakci, Ayse Burcu Kocoglu-Altan, Firat Ozturk, Hasan Babacan, Ruhi Nalcaci대한치과교정학회 · 대한치과교정학회지2015 · 제45권 제2호Three-dimensional analysis of the distal movement of maxillary 1st molars in patients fitted with mini-implant-aided trans-palatal archesAbbas Moghimbeigi, Ahmad Sajedi, Amirfarhang Miresmaeili, Nasrin Farhadian대한치과교정학회 · 대한치과교정학회지2015 · 제45권 제5호

이 간행물의 다른 논문 (5건)