Maxillary Sinus의 inferior wall의 피질골 두께가 임플란트의 초기안정성에 미치는 영향에 대한 in vitro 연구
Primary Stabillity Analysis of Dental Implants According to Cortical Bone Thickness of Maxillary Sinus Inferior Wall In Vitro
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
rimary stability of dental implant is a very important factor of dental implant success. However, few data are available for comparing the primary stability characteristics of less 10mm cancellous and cortical bone thickness. The purpose of this study were to measure the primary implant stability according to sinus inferior wall's cortical bone thickness. Swine bones which have 6,8 and 10 mm bone height and 1 mm and 1.5 mm cortical bone thickness were selected as an experimental model. As treated specimens one side cortical bone was removed. The assemblies were divided into groups of each 30 swine bone specimens according to implant diameter (4.3D group: 4.3mm, 4.8D group: 4.8mm),total bone height (6H group: 6.0mm, 8H group: 8.0mm, 10H group: 10.0mm),and cortical bone thickness (1C: 1.0 mm, 1.5C: 1.5 mm). Implant stability as a function of resonance frequency analysis, peak insertion torque were recorded for each fixture site after placement and removal. The RFA values of 1.5C group was significantly higher than that of 1C group (p < 0.05). The peak insertion torque of 1.5C group was significantly higher than that of 1C group (p < 0.05). Within the limits of this study, thickness of cortical bone have some influences on the primary stability of implants.
Abstract
rimary stability of dental implant is a very important factor of dental implant success. However, few data are available for comparing the primary stability characteristics of less 10mm cancellous and cortical bone thickness. The purpose of this study were to measure the primary implant stability according to sinus inferior wall's cortical bone thickness. Swine bones which have 6,8 and 10 mm bone height and 1 mm and 1.5 mm cortical bone thickness were selected as an experimental model. As treated specimens one side cortical bone was removed. The assemblies were divided into groups of each 30 swine bone specimens according to implant diameter (4.3D group: 4.3mm, 4.8D group: 4.8mm),total bone height (6H group: 6.0mm, 8H group: 8.0mm, 10H group: 10.0mm),and cortical bone thickness (1C: 1.0 mm, 1.5C: 1.5 mm). Implant stability as a function of resonance frequency analysis, peak insertion torque were recorded for each fixture site after placement and removal. The RFA values of 1.5C group was significantly higher than that of 1C group (p < 0.05). The peak insertion torque of 1.5C group was significantly higher than that of 1C group (p < 0.05). Within the limits of this study, thickness of cortical bone have some influences on the primary stability of implants.
참고문헌 (23)
- Zarb GA, "Osseointegration: a requiem for the periodontal ligament", Int J Periodontics Restorative Dent, 11, pp.88~91 (1991)
- Buser D, "Interface shear strength of titanium with sandblasted and acid-etched surface: A biomechanical study in the maxilla of miniature pigs", J Biomed Master Res, 45, pp.75~83 (1999)
- Meredith N, "Assessment of implant stability as a prognostic determinant", Int J Prosthodont, 11, pp.491~501 (1998)
- Meredith N, "Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis", Clin Oral Implants Res, 7(3), pp.261~267 (1996)
- Meredith N, "Resonance frequency measurements of implant stability in vivo. A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla", Clin Oral Implants Res, 8(3), pp.226~233 (1997)
- Meredith N, "The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia", Clin Oral Implants Res, 8(3), pp.234~243 (1997)
- Friberg B, "A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study", Int J Oral Maxillofac Surg, 28(4), pp.297~303 (1999)
- McNutt MD, "Current trends in immediate osseous dental implant case selection criteria", J Dent Edu, 67, pp.850~859 (2003)
- Douglass GL, "The immediate dental implant", J California Dent Assoc, 30, pp.362~365 (2002)
- Fugazzoto PA, "Simplified technique for immediate implant insertion into extraction sockets: report of technique and preliminary results", Implant Dent, 11, pp.79~82 (2002)
- Kaneko TM, "Pulsed oscillation technique for assessing the mechanical state of the dental impant-bone interface", Biomat, 12, pp.555~560 (1991)
- Jemt T, "Failureand complication in 391 consecutively inserted fixed prosthesis supported by Branemark implants in edentulous jaws: A study of treatment from the time of prosthesis placement to the first annual checkup", Int J Oral Maxillofac Implants, 6, pp.270~276 (1991)
- Albrektsson T, "On long-term maintenance of the osseointegrated response", Aust Prosthet J, 7, pp.15~24 (1993)
- Friberg B, "Early failures in 4641consecutively placed Branemark dental implants. A study from stage I surgery to the connection of completed prostheses", Int J Oral Maxillofac Implants, 6, pp.142~146 (1991)
- Graves SL, "Wide diameter implants: indications, considerations and preliminary results over a two-year period", Aust Prosthodont J, 8, pp.31~37 (1994)
- Gentile MA, "Survival estimates and risk factors for failure with 6 5.7-mm implants", Int J Oral Maxillofac Implants, 20, pp.930~937 (2005)
- Holmes DC, "Influence of bone quality on stress distribution for endosseous implants", J Oral Implantol, 23(3), pp.104~111 (1997)
- Saadoun Andre P, "Current Trends in implantology : Part 1 -Biological Response, implant stability, and implant design", Pract Proced Aesthet Dent, 16(7), pp.529~535 (2004)
- O'sullivan, "Measurements comparing the initial stability of five design of dental implants: A human cadaver study", Clin Imp Dent and Related Research, 2(2), pp.85~97 (2000)
- Jung JH, "A retrospective study of the effects on sinus complications of exposing dental implants to the maxillary sinus cavity", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 103(5), pp.623~625 (2007)
- Becker ST, "Prospective observation of 41perforations of the schneiderian membrane during sinus floor elevation", Clin Oral Implants Res, 19(12), pp.1285~1289 (2008)
- Huynh-Ba G, "Implant failure predictors in the posterior maxilla: a retrospective study of 273 consecutive implants", J Periodontal, 79(12), pp.2256~2261 (2008)
- Shen YM, "Osteotome sinus floor elevation without bone grafting: a 2-year prospective clinical study", Shanghai kou Qiang Yi Xue, 18(3), pp.263~266 (2009)
