본문 바로가기
KERD
논문KCI 등재

치료용 고에너지 X-선 장치의 산란선에 의한 개인 피폭 선량계의 방향 및 에너지 의존성에 관한 연구

A Study on the Direction and Energy Dependence of Personal Exposure Dosimeter by Scatter of High Energy Therapeutic X-ray Device

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Using high energy X-ray generators, the scattering lines generated by varying the distance and direction of MU·min-1, which are widely used in the therapeutic radiology field, are measured and compared the direction and energy depending on the sensitivity of each dosimeter by dividing it into a Thermoluminescence dosimeter (TLD), radiophotoluminescence glass dosimeter (PLD) and optical stimulated luminescence dosimeter (OSLD). As a result of the analysis of the difference of dosimeters according to the distance, there was a statistically significant difference (p<0.001). Experiments on the reproducibility of the therapeutic linear accelerator showed that the coefficients of variation were well within 2% (0.02). In addition, the sensitivity of the PLD is excellent when the surface dose measured by the dose rate and distance measurement is analyzed synthetically. Also, comparing the energy dependence of dose, it is found that the TLD with the pearson correlation coefficient close to 1 is superior. In the direction-dependence experiment, The surface dose at 0° to -90° of the TLD showed a reduction rate of 48%. In the PLD, the surface dose at 0° to 90° showed a reduction rate of 74%, In the OSLD, the surface dose of at 0° to 90° showed a reduction rate of 86%. Therefore, the direction dependence of the TLD is the least, and the direction dependence is larger in the order of the PLD and the OSLD. Therefore, in the high energy region, the PLD was excellent as a result of measuring the dose rate and sensitivity of distance, and the TLD was excellent even in the direction dependence experiment. Based on these results, it is necessary to select a personal radiation dosimeter according to the characteristics of the place where the worker is working in the medical field. Accordingly, if it is possible to more accurately measure the effective radiation dose and to prevent the radiation exposure, It will help radiation worker to live a better life.

Abstract

Using high energy X-ray generators, the scattering lines generated by varying the distance and direction of MU·min-1, which are widely used in the therapeutic radiology field, are measured and compared the direction and energy depending on the sensitivity of each dosimeter by dividing it into a Thermoluminescence dosimeter (TLD), radiophotoluminescence glass dosimeter (PLD) and optical stimulated luminescence dosimeter (OSLD). As a result of the analysis of the difference of dosimeters according to the distance, there was a statistically significant difference (p<0.001). Experiments on the reproducibility of the therapeutic linear accelerator showed that the coefficients of variation were well within 2% (0.02). In addition, the sensitivity of the PLD is excellent when the surface dose measured by the dose rate and distance measurement is analyzed synthetically. Also, comparing the energy dependence of dose, it is found that the TLD with the pearson correlation coefficient close to 1 is superior. In the direction-dependence experiment, The surface dose at 0° to -90° of the TLD showed a reduction rate of 48%. In the PLD, the surface dose at 0° to 90° showed a reduction rate of 74%, In the OSLD, the surface dose of at 0° to 90° showed a reduction rate of 86%. Therefore, the direction dependence of the TLD is the least, and the direction dependence is larger in the order of the PLD and the OSLD. Therefore, in the high energy region, the PLD was excellent as a result of measuring the dose rate and sensitivity of distance, and the TLD was excellent even in the direction dependence experiment. Based on these results, it is necessary to select a personal radiation dosimeter according to the characteristics of the place where the worker is working in the medical field. Accordingly, if it is possible to more accurately measure the effective radiation dose and to prevent the radiation exposure, It will help radiation worker to live a better life.

참고문헌 (27)

  1. Araki F, "Measurements of Gamma-Knife helmet output factors using a radiophotoluminescent glass rod dosimeter and a diode detector", Med. Phys, 30(8), pp.1976~1981 (2003)
  2. Explanation material of RPL glass dosimeter; Small element system, "Asahi Techno Glass Corporation", ~ (2000)
  3. 최재호, "DAP(Dose Area Product)를 이용한 TLD와 PLD의 선량 측정 비교", 한국콘텐츠학회 논문지, 12(3), pp.244~250 (2012), 한국콘텐츠학회
  4. Dong KR, "Study on the angular dependence of personal exposure dosimeter - Focus on thermoluminescent dosimeter and photoluminescent dosimeter", Ann. Nucl. Energy, 38(2-3), pp.383~388 (2011)
  5. Ha HY, "A Study for Reduction of Radiation Dose in the Field of Diagnostic Radiology - A point of Tube Voltage and Filtration", J. Radiol. Sci. Technol, 15(1), pp.89~97 (1992)
  6. Huntley DJ, "Optical Dating of Sediments", Nature, 313, pp.105~107 (1985)
  7. ICRP, "1990 Recommendations of the International Commission on Radiological Protection" (1990), Pergamon Press
  8. ICRP, "2007 Recommendations of the International Commission on Radiological Protection" (2007), Pergamon Press
  9. Measurement of Dose Equivalents from External Photon and Electron Radiations, "ICRU", International Commission on Radiation Units and Measurements, ~, pp.ICRU Report 47 (1992)
  10. Quantities and Units in Radiation Protection Dosimetry, "ICRU", ICRU, ~, pp.ICRU Report 51 (1993)
  11. 전미은, "방사선 중재적 시술 중 시술자의 피폭선량에 대한 연구", 방사선기술과학, 35(3), pp.219~226 (2012), 대한방사선과학회
  12. Kim DS, "The light sensitivity and angular dependence of the Mg2SIO4:(MSO-S)TLD", J. Korea Asso. Radiat. Prot, 23(1), pp.59~63 (1998)
  13. Ko SG, "A Study of X-ray Output for Diagnostic X-ray Equipment", J. Radiol. Sci. Technol, 18(2), pp.61~73 (1995)
  14. 권정완, "후방피폭선량계측이 가능한 TL 개인선량계의 설계 및 선량평가 알고리즘 개발", 방사선방어학회지, 29(3), pp.179~186 (2004), 대한방사선방어학회
  15. Le Masson NJM, "Optically Stimulated Luminescence in KMgF3: Ce3+ Comparison of Dosimetric Characteristics With Al2O3 : C", IEEE Transactions Nucl. Sci, 48(4), pp.1143~1147 (2001)
  16. Lee HY, "Radiation Doses from Occupational Exposure to the Radiological Workers", Report of NIH Korea, 23, pp.831~832 (1987)
  17. Lim CS, "Performance of optically stimulated luminescence Al2O3 dosimeter for low doses of diagnostic energy X-rays", Appl. Radiat. Isotop, 69(10), pp.4186~1489 (2011)
  18. Mckeever SW, "New Millennium Frontiers of Luminescence Dosimetry", Radiat. Prot. Dosim, 100(1-4), pp.27~32 (2002)
  19. Mobit PN, "The quality dependence of LiF TLD in megavoltage photon beams: Mont Carlosimulation and experiments", Phys. Med. Biol, 41(3), pp.387~398 (1996)
  20. Mobit PN, "A Monte Carlo study of the quality dependence factors of common TLD materials in photon and electron beam", Phys. Med. Biol, 43(8), pp.2015~2032 (1998)
  21. Park MH, "The Compensation of the Energy Dependence of TLD", J. Radiol. Sci. Technol, 16(2), pp.51~60 (1993)
  22. 박세환, "사용후핵연료 연소도 측정을 위한 이온 챔버 제작", 방사선방어학회지, 35(1), pp.21~25 (2010), 대한방사선방어학회
  23. Park SH, "Saturation characteristics of the ionization chamber at a low dose rate", Radiat. Phys. Chem, 73(5), pp.248~253 (2005)
  24. Pradhan AS, "Thermoluminescence Dosimetry and its applications", Radiat. Prot. Dosim, 1(3), pp.153~167 (1981)
  25. Pradhan AS, "Recent developments of optically stimulated luminescence materials and techniques for radiation dosimetry and clinical applications", J. Med. Phys, 33(3), pp.85~99 (2008)
  26. 라정은, "유리선량계의 선량 특성에 관한 연구", 방사선방어학회지, 31(4), pp.181~186 (2006), 대한방사선방어학회
  27. Tsuda M., "A few remarks on photoluminescence dosimetry with high energy x-ray", Japanese J. Med. Phys, 20(3), pp.131~139 (2000)

관련 논문AI추천

이 간행물의 다른 논문 (12건)