1.5T와 3.0T MRI 검사실 문의 개폐에 따른 소음 및 영상에 대한 MR 펄스시퀀스 측정
Measurement of MR Pulse Sequence for Acoustic Noise and Image Quality of Opening and Closing Door in 1.5T and 3.0T MRI Scanning Room
0
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
The acoustic noise was measured and images were evaluated in TSE (turbo spin echo), GE (gradient echo) and FLAIR (fluid attenuated inversion recovery) pulse sequences according to the opening and closing of the MR test room of 1.5T and 3.0T. The 1.5T and 3.0T MR and the ACR phantom were used to measure the noise due to opening and closing of the door according to the pulse sequence. Statistical analysis of the significance test was performed using paired t-test. The images were measured by using ImageJ program to measure SNR, PSNR, RMSE, and MAE. At 1.5T the average acoustic noise is when the room door is opened TSE (61.75 dB), FLAIR (57 dB) and GE (48.7 dB) when the door was closed. At the time of opening the 3.0T room, TSE (88.35 dB), FLAIR (74.85 dB), GE (67.1 dB), TSE (60.4 dB), FLAIR (59.8 dB) and GE (46.7 dB) were closed when the door was opened. When closed, the acoustic noise reduction was decreased from 1.5T to 27.4% for GE, 25.9% for TSE, 22.6% for FLAIR, 46.2% for TSE, 43.6% for GE, and 25.1% (p<.05), and the pulse sequence according to the noise was statistically significant (p<.05). In the ACR phantom image, PSNR was 32.189 dB at 1.5T, 3.0T was 30.361 dB, and RMSE and MAE were 11.183, 6.361, and 3.0T, respectively, at 33.43 and 21.475. 1.5T, GE, TSE, FLAIR, 3.0T, TSE, GE, and FLAIR, respectively, and noise reduction was confirmed when the door was closed.
Abstract
The acoustic noise was measured and images were evaluated in TSE (turbo spin echo), GE (gradient echo) and FLAIR (fluid attenuated inversion recovery) pulse sequences according to the opening and closing of the MR test room of 1.5T and 3.0T. The 1.5T and 3.0T MR and the ACR phantom were used to measure the noise due to opening and closing of the door according to the pulse sequence. Statistical analysis of the significance test was performed using paired t-test. The images were measured by using ImageJ program to measure SNR, PSNR, RMSE, and MAE. At 1.5T the average acoustic noise is when the room door is opened TSE (61.75 dB), FLAIR (57 dB) and GE (48.7 dB) when the door was closed. At the time of opening the 3.0T room, TSE (88.35 dB), FLAIR (74.85 dB), GE (67.1 dB), TSE (60.4 dB), FLAIR (59.8 dB) and GE (46.7 dB) were closed when the door was opened. When closed, the acoustic noise reduction was decreased from 1.5T to 27.4% for GE, 25.9% for TSE, 22.6% for FLAIR, 46.2% for TSE, 43.6% for GE, and 25.1% (p<.05), and the pulse sequence according to the noise was statistically significant (p<.05). In the ACR phantom image, PSNR was 32.189 dB at 1.5T, 3.0T was 30.361 dB, and RMSE and MAE were 11.183, 6.361, and 3.0T, respectively, at 33.43 and 21.475. 1.5T, GE, TSE, FLAIR, 3.0T, TSE, GE, and FLAIR, respectively, and noise reduction was confirmed when the door was closed.
참고문헌 (19)
- Francis JM, "Treatment of claustrophobia for cardiovascular magnetic resonance: use and effectiveness of mild sedation", J. Cardiovasc. Magn. Reson, 2(2), pp.139~141 (2000)
- 한용수, "Effects of Contrast Agent Concentration on the Signal Intensity and Turbo Factor of TSE and Slice-selective IR in T1-weighted Contrast Imaging", Journal of Magnetics, 21(1), pp.115~124 (2016), 한국자기학회
- Hayes CE, "Noise correlations in data simultaneously acquired from multiple surface coil arrays", Magn. Reson. Med, 16(2), pp.181~191 (1990)
- Hennel F, "'Silent' MRI with soft gradient pulses", Magn. Reson. Med, 42(1), pp.6~10 (1999)
- 김지민, "Light Probe를 이용한 MRI 검사실 및 모니터의 조도와 휘도 측정", 한국자기학회지, 26(5), pp.168~172 (2016), 한국자기학회
- 이록행, "MRI 소음의 특성을 이용한 공동 내부 목표점의 능동소음 제어", 한국소음진동공학회논문집, 24(1), pp.62~68 (2014), 한국소음진동공학회[DOI]
- Li G, "A comprehensive experimental study of micro-perforated panel acoustic absorbers in MRI scanners", Magn. Reson. Mater Phys. Biol. Med, 23(3), pp.177~185 (2010)
- Masuda J, "Silent stroke: pathogenesis, genetic factors and clinical implications as a risk factor", Curr. Opin. Neurol, 14(1), pp.77~82 (2001)
- McGlynn FD, "Component fears of claustrophobia associated with mock magnetic resonance imaging", J. Anxiety Disord, 21(3), pp.367~380 (2007)
- McJury MJ, "Acoustic noise levels generated during high field MR imaging", Clin. Radiol, 50(5), pp.331~334 (1995)
- Nazemi H, "Coping strategies of panic and control subjects undergoing lactate infusion during magnetic resonance imaging confinement", Compr. Psychiatry, 44(3), pp.190~197 (2003)
- 박영혜, "자기공명영상(MRI) 검사전,후 불안민감성 제수준에 따른 폐쇄공포, 소음민감성 및 활력징후 비교", 성인간호학회지, 20(6), pp.950~959 (2008), 한국성인간호학회
- M. Periyasamy, "Interference Issuses of Radio Frequency Identification Devices in Magnetic Resonance Imaging Systems and Computed Tomography Scan", Journal of Magnetics, 20(3), pp.295~301 (2015), 한국자기학회
- Pierre EY, "Parallel imaging-based reduction of acoustic noise for clinical magnetic resonance imaging", Invest. Radiol, 49(9), pp.620~626 (2014)
- Price DL, "Investigation of acoustic noise on 15 MRI scanners from 0.2T to 3T", J. Magn. Reson. Imaging, 13(2), pp.288~293 (2001)
- Roemer PB, "The NMR phased array", Magn. Reson. Med, 16(2), pp.192~225 (1990)
- Shellock FG, "MR labeling information for implants and devices: explanation of terminology", Radiology, 253(1), pp.26~30 (2009)
- Yanasak NE, "MR imaging artifacts and parallel imaging techniques with calibration scanning: a new twist on old problems", Radiographics, 34(2), pp.532~548 (2014)
- 예수영, "HRV를 이용한 자기공명영상 소음의 시간 변화에 따른스트레스 평가", 융합신호처리학회 논문지, 16(2), pp.50~55 (2015), 한국융합신호처리학회