본문 바로가기
KERD
논문KCI 등재

Posterior dental implant prosthesis fabrication using double scanning technique: a case report

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

The disadvantages of the traditional approach for fabricating dental implant prostheses have been addressed via oral scanning and the use of computer-aided design/computer-aided manufacturing systems. The use of an intraoral scanner can eliminate the need for impression materials and impression trays, which are inconvenient for patients, particularly those with limited mouth opening or an overly sensitive gag reflex. Moreover, it can reduce the additional costs of fabricating, storing, and handling the patients’ models. This case report describes the fabrication of a posterior implant prosthesis using double scanning technique, which produced satisfactory results both esthetically and functionally. The double scanning technique produces a more accurate image of the target region by overlapping data from both intraoral and extraoral scans. Therefore, it can address the disadvantages of both traditional and digital impressions, reduce patient discomfort, and decrease the incidence of remakes, which can arise due to potential errors during the fabrication process.

Abstract

The disadvantages of the traditional approach for fabricating dental implant prostheses have been addressed via oral scanning and the use of computer-aided design/computer-aided manufacturing systems. The use of an intraoral scanner can eliminate the need for impression materials and impression trays, which are inconvenient for patients, particularly those with limited mouth opening or an overly sensitive gag reflex. Moreover, it can reduce the additional costs of fabricating, storing, and handling the patients’ models. This case report describes the fabrication of a posterior implant prosthesis using double scanning technique, which produced satisfactory results both esthetically and functionally. The double scanning technique produces a more accurate image of the target region by overlapping data from both intraoral and extraoral scans. Therefore, it can address the disadvantages of both traditional and digital impressions, reduce patient discomfort, and decrease the incidence of remakes, which can arise due to potential errors during the fabrication process.

참고문헌 (16)

  1. Francesco Mangano, "A Novel Full-Digital Protocol (SCAN-PLAN-MAKE-DONE®) for the Design and Fabrication of Implant-Supported Monolithic Translucent Zirconia Crowns Cemented on Customized Hybrid Abutments: A Retrospective Clinical Study on 25 Patients", International Journal of Environmental Research and Public Health, 16(3), pp.317~ (2019), MDPI AG[DOI]
  2. Francesco Mangano, "Intraoral scanners in dentistry: a review of the current literature", BMC Oral Health, 17(1), pp.149~ (2017), Springer Science and Business Media LLC[DOI]
  3. Tim Joda, "The complete digital workflow in fixed prosthodontics: a systematic review", BMC Oral Health, 17(1), pp.124~ (2017), Springer Science and Business Media LLC[DOI]
  4. Jan K. Pietruski, "Evaluation of concordance between CAD", CAM and clinical positions of abutment shoulder against mucosal margin: an observational study, 2018, pp.18(1), 73~[DOI]
  5. 김준엽, "구치부 보철 수복 공간이 부족한 환자에서 이중 스캔을 이용한 구강회복 증례", 대한치과보철학회지, 55(2), pp.205~211 (2017), 대한치과보철학회[DOI]
  6. 양동헌, "임시치아 double scanning을 이용한 전악 임플란트 수복 증례", 대한치과보철학회지, 52(3), pp.252~257 (2014), 대한치과보철학회[DOI]
  7. 장은선, "DMLS (Direct Metal Laser Sintering) 기술을 이용한 가철성 국소의치 수리 증례", 대한치과보철학회지, 58(3), pp.251~256 (2020), 대한치과보철학회[DOI]
  8. T. Stober, "Enamel wear caused by monolithic zirconia crowns after 6 months of clinical use", Journal of Oral Rehabilitation, 41(4), pp.314~322 (2014), Wiley[DOI]
  9. Taiseer A. Sulaiman, "Optical properties and light irradiance of monolithic zirconia at variable thicknesses", Dental Materials, 31(10), pp.1180~1187 (2015), Elsevier BV[DOI]
  10. Bremer F, "In vivo biofilm formation on different dental ceramics", Quintessence Int, 42, pp.565~574 (2011)
  11. 윤세나, "Full mouth rehabilitation of a severely worn dentition using intraoral scanner and the CAD", CAM double scanning technique, 2020, pp.58(1), 67~76[DOI]
  12. Shereen S. Azer, "A Simplified Technique for Creating a Customized Gingival Emergence Profile for Implant-Supported Crowns", Journal of Prosthodontics, 19(6), pp.497~501 (2010), Wiley[DOI]
  13. 김진완, "치은연하 변연을 가지는 맞춤형 지대주에서 디지털 중첩기술을 이용한 인상채득술의 임상 적용 증례", 대한치과보철학회지, 58(2), pp.169~175 (2020), 대한치과보철학회[DOI]
  14. Youngwook Cho, "The rehabilitation of an edentulous mandible with a CAD", CAM zirconia framework and heat-pressed lithium disilicate ceramic crowns: A clinical report, 2014, pp.111(6), 443~447[DOI]
  15. 홍영택, "잠정수복물의 최종수복물로의 디지털 복제를 통한 완전구강회복 증례: Double scan technique", 대한치과보철학회지, 59(1), pp.63~70 (2021), 대한치과보철학회[DOI]
  16. 고창우, "비심미적인 상악 전치부 환자에서 이중 스캔을 이용한 심미보철 수복 증례", 대한치과보철학회지, 56(2), pp.166~172 (2018), 대한치과보철학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (8건)