Comparison of fixed dental prostheses digitally fabricated using various scan bodies: a clinical study

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose. Digitalization in dentistry has increased interest in the use of intraoral scanners (IOs) in clinical practice. However, knowledge of implant digitalization is primarily limited to in vitro studies. This study aimed to compare implant-supported fixed dental prostheses (FDP) fabricated following complete digital workflow using various implant scan bodies (SB) in treatment of short-span partial edentulism. Materials and methods. Patients with 25 short-span posterior edentulous sites, each receiving two implants to support a fixed restoration, were included. Digital implant records were made consecutively with original, non-original, and generic SBs using IOs. A practitioner implemented a two-stage full-arch scanning protocol, beginning with continuous arch scanning, followed by individual scanning of SBs. For clinical evaluation, each site received screw-retained full-contour restorations to qualify the connection fit to the implants and contacts to the adjacent and antagonist teeth. For analytical comparison, implant axes calculated from SB scans were quantified using reverse engineering software to compare the differences three-dimensionally. Restorative outcomes and implant axes records were statistically analyzed using the chi-square test and generalized estimating equations, respectively. Results. Clinical delivery conditions did not differ significantly among the three intraoral SBs (P > .05). The analytical implant-position calculations for non-original and generic SBs did not present significant differences compared to original SBs (P > .05). Conclusion. SBs with different hardware and software characteristics for an implant system are clinically acceptable for fabricating screw-retained short-span implant-supported FDPs using a complete digital workflow.

Abstract

Purpose. Digitalization in dentistry has increased interest in the use of intraoral scanners (IOs) in clinical practice. However, knowledge of implant digitalization is primarily limited to in vitro studies. This study aimed to compare implant-supported fixed dental prostheses (FDP) fabricated following complete digital workflow using various implant scan bodies (SB) in treatment of short-span partial edentulism. Materials and methods. Patients with 25 short-span posterior edentulous sites, each receiving two implants to support a fixed restoration, were included. Digital implant records were made consecutively with original, non-original, and generic SBs using IOs. A practitioner implemented a two-stage full-arch scanning protocol, beginning with continuous arch scanning, followed by individual scanning of SBs. For clinical evaluation, each site received screw-retained full-contour restorations to qualify the connection fit to the implants and contacts to the adjacent and antagonist teeth. For analytical comparison, implant axes calculated from SB scans were quantified using reverse engineering software to compare the differences three-dimensionally. Restorative outcomes and implant axes records were statistically analyzed using the chi-square test and generalized estimating equations, respectively. Results. Clinical delivery conditions did not differ significantly among the three intraoral SBs (P > .05). The analytical implant-position calculations for non-original and generic SBs did not present significant differences compared to original SBs (P > .05). Conclusion. SBs with different hardware and software characteristics for an implant system are clinically acceptable for fabricating screw-retained short-span implant-supported FDPs using a complete digital workflow.

관련 논문AI추천

Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical studyAgne Gedrimiene, Rimas Adaskevicius, Vygandas Rutkunas대한치과보철학회 · The Journal of Advanced of Prosthodontics2019 · 제11권 제5호Effect of the scan body alignment process on the accuracy of virtual definitive implant casts: a pilot studyAna Suárez, Andrea Santamaría Laorden, Cristina Andreu Vázquez, Jaime Orejas Pérez대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제5호Effects of scan body material, length and top design on digital implant impression accuracy and usability: an in vitro studyAnn Wennerberg, Julian Hessel Baranowski, Michael Braian, Victoria Franke Stenport대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제3호Effect of reference objects on the accuracy of digital implant impressions in partially edentulous archesAgnė Gedrimienė, Darius Jegelevičius, Justinas Pletkus, Liudas Auškalnis, Mutlu Özcan, Mykolas Akulauskas, Tan Fırat Eyüboğlu, Vygandas Rutkūnas대한치과보철학회 · The Journal of Advanced of Prosthodontics2024 · 제16권 제5호Comparison of Accuracy in Digital Implant Impression using Dedicated and Compatible Scanbodies김준성, 손미경, 장근운, 허유리대한구강악안면임플란트학회 · 대한구강악안면임플란트학회지2022 · 제26권 제1호The effect of the improperly scanned scan body images on the accuracy of virtual implant positioning in computer-aided design software박세원, 이두형, 최용도대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제3호

이 간행물의 다른 논문 (4건)