Fabricating an Implant-Supported Crown with Impression Scanning Technology
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: Computer-aided design and computer-aided manufacturing (CAD/CAM) technology automates the fabrication process of implant-supported prostheses. For the CAD/CAM fabrication of implant-supported crowns, virtual models must be generated by capturing of the intraoral situation with intraoral scanners or by digitizing stone casts with laboratory scanners. This article describes a novel method for creating virtual models with impression scanning technology. By using this workflow, an implant-supported crown is rapidly fabricated without intraoral scanning and cast scanning which needs additional time for fabricating stone casts.
Abstract
Purpose: Computer-aided design and computer-aided manufacturing (CAD/CAM) technology automates the fabrication process of implant-supported prostheses. For the CAD/CAM fabrication of implant-supported crowns, virtual models must be generated by capturing of the intraoral situation with intraoral scanners or by digitizing stone casts with laboratory scanners. This article describes a novel method for creating virtual models with impression scanning technology. By using this workflow, an implant-supported crown is rapidly fabricated without intraoral scanning and cast scanning which needs additional time for fabricating stone casts.
참고문헌 (25)
- Kapos T, "Computer-aided design and computer-assisted manufacturing in prosthetic implant dentistry", Int J Oral Maxillofac Implants, 24(suppl), pp.110~117 (2009)
- Kapos T, "CAD", CAM technology for implant abutments, crowns, and superstructures, 2014, pp.29(suppl), 117~136
- Alghazzawi TF, "Advancements in CAD", CAM technology: Options for practical implementation, 2016, pp.60, 72~84
- Fluegge T, "A novel method to evaluate precision of optical implant impressions with commercial scan bodies-an experimental approach", J Prosthodont, 26, pp.34~41 (2017)
- Joda T, "Digital technology in fixed implant prosthodontics", Periodontol 2000, 73, pp.178~192 (2017)
- Schepke U, "Digital versus analog complete-arch impressions for singleunit premolar implant crowns: operating time and patient preference", J Prosthet Dent, 114, pp.403~406 (2015)
- Zimmermann M, "Intraoral scanning systems - a current overview", Int J Comput Dent, 18, pp.101~129 (2015)
- Chochlidakis KM, "Digital versus conventional impressions for fixed prosthodontics: A systematic review and meta-analysis", J Prosthet Dent, 116, pp.184~190 (2016)
- Henry PJ, "Dimensional stability and accuracy of rubber impression materials", Aust Dent J, 19, pp.162~166 (1974)
- Lacy AM, "Time-dependent accuracy of elastomer impression materials. Part II: Polyether, polysulfides, and polyvinylsiloxane", J Prosthet Dent, 45, pp.329~333 (1981)
- Joda T, "Digital vs. conventional implant prosthetic workflows: A cost", time analysis, 2015, pp.26, 1430~1435
- Jeon JH, "Three-dimensional evaluation of the repeatability of scanned conventional impressions of prepared teeth generated with white- and blue-light scanners", J Prosthet Dent, 114, pp.549~553 (2015)
- Jeon JH, "Three-dimensional evaluation of the repeatability of scans of stone models and impressions using a blue LED scanner", Dent Mater J, 34, pp.686~691 (2015)
- 전진훈, "Repeatability and reproducibility of individual abutment impression, assessed with a blue light scanner", The Journal of Advanced of Prosthodontics, 8(3), pp.214~218 (2016), 대한치과보철학회[DOI]
- Matta RE, "Accuracy of impression scanning compared with stone casts of implant impressions", J Prosthet Dent, 117, pp.507~512 (2017)
- Mandelli F, "Improvement of a digital impression with conventional materials: overcoming intraoral scanner limitations", Int J Prosthodont, 30, pp.373~376 (2017)
- Lee B, "Evaluation of the fit of zirconia copings fabricated by direct and indirect digital impression procedures", J Prosthet Dent, 120, pp.225~231 (2018)
- Wilson EG, "Double arch impressions for simplified restorative dentistry", J Prosthet Dent, 49, pp.198~202 (1983)
- Donovan TE, "A review of contemporary impression materials and techniques", Dent Clin North Am, 48, pp.445~470 (2004)
- Johnson GH, "Clinical trial investigating success rates for polyether and vinyl polysiloxane impressions made with full-arch and dual-arch plastic trays", J Prosthet Dent, 103, pp.13~22 (2010)
- 이주형, "A Completely Cast-Free, Digital Workflow for Fabricating an Implant-Supported Prosthesis with a New Coded Healing Abutment", 대한구강악안면임플란트학회지, 23(1), pp.26~35 (2019), 대한구강악안면임플란트학회[DOI]
- Parpaiola A, "Virtual abutment design: A concept for delivery of CAD", CAM customized abutments - report of a retrospective cohort, 2013, pp.33, 51~58
- Goldstein G, "Finding Z: A mathematical method for predicting tissue position after implant abutment-restoration placement", J Prosthet Dent, 112, pp.322~324 (2014)
- Mehl A, "A new concept for the integration of dynamic occlusion in the digital construction process", Int J Comput Dent, 15, pp.109~123 (2012)
- Moráguez OD, "The use of polytetrafluoroethylene tape for the management of screw access channels in implant-supported prostheses", J Prosthet Dent, 103, pp.189~191 (2010)
