Evaluation of BacT/Alert FAN Plus Bottles for the Culture of Peritoneal Dialysate
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background: A major complication of peritoneal dialysis (PD) is peritonitis, and bacterial culture of PD effluent in a blood culture bottle is the preferred technique for diagnosis of peritonitis. In this study, we compared dialysate inoculation and culture using the BacT/AlerTⓇ Fastidious Antimicrobial Neutralization Plus blood culture bottles (FAN Plus; bioMérieux, France) to the conventional centrifugation culture method. Methods: A total of 170 PD effluents were simultaneously processed by the conventional centrifugation culture method and by culture using FAN Plus media with two different inoculation procedures: inoculation after centrifugation and direct bedside inoculation. Results: Of the 52 cultures that were positive on at least one of the culture methods, 27 samples were positive on conventional centrifugation. However, 46 samples showed growth following inoculation into the FAN Plus media after centrifugation, and 47 samples were positive on the direct FAN Plus inoculation method. Using the case definition for PD peritonitis to classify samples, sensitivity of the conventional method was 50.0% (95% CI, 33.7-66.3%), whereas the sensitivity of the FAN Plus media was 78.9% (95% CI, 62.2-89.9%) by inoculation after centrifugation and 86.8% (95% CI, 71.1-95.1%) by direct inoculation. Use of both inoculation methods with FAN Plus media resulted in 92.1% sensitivity (95% CI, 89.2-99.9%). Conclusion: Culture using FAN Plus media demonstrated a superior bacterial recovery rate to the conventional centrifugation culture method. A combination of the two inoculation methods with FAN Plus media is recommended for the best diagnostic yield, while direct inoculation alone can be useful due to its simplicity and cost-effectiveness. (Ann Clin Microbiol 2019;22:90-95)
Abstract
Background: A major complication of peritoneal dialysis (PD) is peritonitis, and bacterial culture of PD effluent in a blood culture bottle is the preferred technique for diagnosis of peritonitis. In this study, we compared dialysate inoculation and culture using the BacT/AlerTⓇ Fastidious Antimicrobial Neutralization Plus blood culture bottles (FAN Plus; bioMérieux, France) to the conventional centrifugation culture method. Methods: A total of 170 PD effluents were simultaneously processed by the conventional centrifugation culture method and by culture using FAN Plus media with two different inoculation procedures: inoculation after centrifugation and direct bedside inoculation. Results: Of the 52 cultures that were positive on at least one of the culture methods, 27 samples were positive on conventional centrifugation. However, 46 samples showed growth following inoculation into the FAN Plus media after centrifugation, and 47 samples were positive on the direct FAN Plus inoculation method. Using the case definition for PD peritonitis to classify samples, sensitivity of the conventional method was 50.0% (95% CI, 33.7-66.3%), whereas the sensitivity of the FAN Plus media was 78.9% (95% CI, 62.2-89.9%) by inoculation after centrifugation and 86.8% (95% CI, 71.1-95.1%) by direct inoculation. Use of both inoculation methods with FAN Plus media resulted in 92.1% sensitivity (95% CI, 89.2-99.9%). Conclusion: Culture using FAN Plus media demonstrated a superior bacterial recovery rate to the conventional centrifugation culture method. A combination of the two inoculation methods with FAN Plus media is recommended for the best diagnostic yield, while direct inoculation alone can be useful due to its simplicity and cost-effectiveness. (Ann Clin Microbiol 2019;22:90-95)
참고문헌 (28)
- Al-Allak A, "Long-term outcome of continuous ambulatory peritoneal dialysis(CAPD)peritonitis : surgery can be avoided", Ann R Coll Surg Engl, 91, pp.118~122 (2009)
- 윤세희, "Detecting Bacterial Growth in Continuous Ambulatory Peritoneal Dialysis Effluent Using Two Culture Methods", The Korean Journal of Internal Medicine, 25(1), pp.82~85 (2010), 대한내과학회
- Li PK, "ISPD peritonitis recommendations : 2016 update on prevention and treatment", Perit Dial Int, 36, pp.481~508 (2016)
- Alfa MJ, "Improved detection of bacterial growth in continuous ambulatory peritoneal dialysis effluent by use of BacT", Alert FAN bottles, 1997, pp.35, 862~866
- Rayner BL, "Inoculation of peritoneal dialysate fluid into blood culture bottles improves culture rates", S Afr Med J, 83, pp.42~43 (1993)
- Azap OK, "Value of automatized blood culture systems in the diagnosis of continuous ambulatory peritoneal dialysis peritonitis", Transplant Proc, 38, pp.411~412 (2006)
- Males BM, "Addi-Chek filtration, BACTEC, and 10-ml culture methods for recovery of microorganisms from dialysis effluent during episodes of peritonitis", J Clin Microbiol, 23, pp.350~353 (1986)
- Iyer RN, "Evaluation of different culture methods for the diagnosis of peritonitis in patients on continuous ambulatory peritoneal dialysis", Clin Microbiol Infect, 20, pp.O294~O296 (2014)
- Stokely DJ, "Isolation of organisms in CAPD peritonitis : use of nutrient broth cultures and Bactec blood culture media", J Hosp Infect, 11, pp.77~81 (1998)
- Chow KM, "Continuous ambulatory peritoneal dialysis peritonitis: broth inoculation culture versus water lysis method", Nephron Clin Pract, 105, pp.c121~c125 (2007)
- Ahmadi S, "Evaluation of modified laboratory processes for isolation of bacteria and fungi in continuous ambulatory peritoneal dialysis patients with peritonitis", Perit Dial Int, 35, pp.767~769 (2015)
- Thomson RB, "Clinical Microbiology Procedures Handbook", pp.3.5.1~3.5.9 (2016), ASM Press
- Gupta S, "Epidemiology of culture isolates from peritoneal dialysis peritonitis patients in southern India using an automated blood culture system to culture peritoneal dialysate", Nephrology(Carlton), 16, pp.63~67 (2011)
- Lye WC, "Isolation of organisms in CAPD peritonitis : a comparison of two techniques", Adv Perit Dial, 10, pp.166~168 (1994)
- Weinstein MP, "Controlled evaluation of BacT", Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia, 1995, pp.33, 978~981
- Flayhart D, "Comparison of BACTEC PLUS blood culture media to BacT", Alert FA blood culture media for detection of bacterial pathogens in samples containing therapeutic levels of antibiotics, 2007, pp.45, 816~821
- Zadroga R, "Comparison of 2 blood culture media shows significant differences in bacterial recovery for patients on antimicrobial therapy", Clin Infect Dis, 56, pp.790~797 (2013)
- Kirn TJ, "Controlled clinical comparison of BacT", alert FA plus and FN plus blood culture media with BacT, J Clin Microbiol, pp.2014, 52[DOI]
- Lovern D, "Antimicrobial binding and growth kinetics in BacT", ALERTⓇFA Plus and BACTECⓇ Aerobic, Eur J Clin Microbiol Infect Dis, pp.2016, 35[DOI]
- Lee DH, "Clinical evaluation of BacT", Alert FA plus and FN plus bottles compared with standard bottles, 2013, pp.51, 4150~4155
- De Keukeleire S, "Performance of BacT", Alert resin-based FN plus bottles compared with BacT, Anaerobe, pp.2015, 35(Pt B)[DOI]
- Amarsy-Guerle R, "High medical impact of implementing the new polymeric bead-based BacT", ALERTⓇ FAPlus and FNPlus blood culture bottles in standard care, 2015, pp.34, 1031~1037
- Hughes JG, "Culture with BACTEC Peds Plus", F bottle compared with conventional methods for detection of bacteria in synovial fluid, 2001, pp.39, 4468~4471
- Yoo IY, "Comparison of BacT", Alert FAN and FAN plus bottles with conventional medium for culturing cerebrospinal fluid, 2016, pp.54, 2837~2840
- Chang YT, "Rapid identification of bacteria and Candida pathogens in peritoneal dialysis effluent from patients with peritoneal dialysisrelated peritonitis by use of multilocus PCR coupled with electrospray ionization mass spectrometry", J Clin Microbiol, 52, pp.1217~1219 (2014)
- 김시현, "Evaluation of DNA Extraction Methods and Their Clinical Application for Direct Detection of Causative Bacteria in Continuous Ambulatory Peritoneal Dialysis Culture Fluids from Patients with Peritonitis by Using Broad-Range PCR", Annals of Laboratory Medicine, 32(2), pp.119~125 (2012), 대한진단검사의학회
- Najafi I, "Seventeen years' experience of peritoneal dialysis in Iran : first official report of the Iranian peritoneal dialysis registry", Perit Dial Int, 34, pp.636~642 (2014)
- Nishina M, "A 10-year retrospective cohort study on the risk factors for peritoneal dialysis-related peritonitis : a single-center study at Tokai University Hospital", Clin Exp Nephrol, 18, pp.649~654 (2014)
