본문 바로가기
KERD
논문KCI 등재

Comparison of Clinical Performance Between BacT/ Alert Virtuo and BacT/Alert 3D Blood Culture Systems

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류병리학

초록

Background: BacT/Alert Virtuo (BioMérieux, Durham, NC, USA) is a recently developed blood culture system that includes functions of automatic registration, loading, and unloading of the blood culture bottles, as well as measurement of blood volume. We compared the performances between the BacT/Alert Virtuo and 3D (BioMérieux) blood culture systems. Methods: A total of 952 patients (1,904 sets) visiting an university-affiliated hospital in Korea for blood cultures were enrolled. Five milliliters of blood was added into each of the two aerobic (FA Plus) and two anaerobic (FN Plus) bottles of the Virtuo and 3D systems for a single set. Positive rate and time to detection (TTD) were compared between the two systems. Results: The positive rates were 8.3% and 8.4% in FA Plus bottles and 7.8% and 8.3% in FN Plus bottles, in the Virtuo and 3D systems, respectively (P >0.05). Median TTDs were shorter in the Virtuo than in the 3D system for all isolates (11.5 hours [N=305] vs 11.8 hours [N=318], P <0.001), Staphylococcus aureus (N=38; 14.3 hours vs 16.0 hours, P =0.021), and Escherichia coli (N=117; 10.4 hours vs 11.0 hours, P <0.001). Conclusions: The Virtuo has the potential to detect pathogens early in all bottle types. This might improve the prognosis of sepsis by allowing for implementation of expeditious management.

Abstract

Background: BacT/Alert Virtuo (BioMérieux, Durham, NC, USA) is a recently developed blood culture system that includes functions of automatic registration, loading, and unloading of the blood culture bottles, as well as measurement of blood volume. We compared the performances between the BacT/Alert Virtuo and 3D (BioMérieux) blood culture systems. Methods: A total of 952 patients (1,904 sets) visiting an university-affiliated hospital in Korea for blood cultures were enrolled. Five milliliters of blood was added into each of the two aerobic (FA Plus) and two anaerobic (FN Plus) bottles of the Virtuo and 3D systems for a single set. Positive rate and time to detection (TTD) were compared between the two systems. Results: The positive rates were 8.3% and 8.4% in FA Plus bottles and 7.8% and 8.3% in FN Plus bottles, in the Virtuo and 3D systems, respectively (P >0.05). Median TTDs were shorter in the Virtuo than in the 3D system for all isolates (11.5 hours [N=305] vs 11.8 hours [N=318], P <0.001), Staphylococcus aureus (N=38; 14.3 hours vs 16.0 hours, P =0.021), and Escherichia coli (N=117; 10.4 hours vs 11.0 hours, P <0.001). Conclusions: The Virtuo has the potential to detect pathogens early in all bottle types. This might improve the prognosis of sepsis by allowing for implementation of expeditious management.

참고문헌 (18)

  1. CLSI, "Principles and procedures for blood cultures; approved guideline M47-A", Clinical and Laboratory Standards Institute, ~ (2007)
  2. Pien BC, "The clinical and prognostic importance of positive blood cultures in adults", Am J Med, 123, pp.819~828 (2010)
  3. Goto M, "Overall burden of bloodstream infection and nosocomial bloodstream infection in North America and Europe", Clin Microbiol Infect, 19, pp.501~509 (2013)
  4. Barenfanger J, "Decreased mortality associated with prompt Gram staining of blood cultures", Am J Clin Pathol, 130, pp.870~876 (2008)
  5. Opota O, "Blood culture-based diagnosis of bacteraemia : state of the art", Clin Microbiol Infect, 21, pp.313~322 (2015)
  6. Kirn TJ, "Update on blood cultures : how to obtain, process, report, and interpret", Clin Microbiol Infect, 19, pp.513~520 (2013)
  7. Bouza E, "Is the volume of blood cultured still a significant factor in the diagnosis of bloodstream infections", J Clin Microbiol, 45, pp.2765~2769 (2007)
  8. Jacobs MR, "Multicenter clinical evaluation of BacT", Alert Virtuo blood culture system, 2017, pp.55, 2413~2421
  9. Akan OA, "Comparison of the effect of delayed entry into 2 different blood culture systems(BACTEC 9240 and BacT", ALERT 3D)on culture positivity, 2006, pp.54, 193~196
  10. van der Velden LB, "Clinical impact of preincubation of blood cultures at 37°C", J Clin Microbiol, 49, pp.275~280 (2011)
  11. Brown DF, "Effect of sample volume on yield of positive blood cultures from adult patients with haematological malignancy", J Clin Pathol, 43, pp.777~779 (1990)
  12. Kim SC, "Effect of blood volume in standard anaerobic blood culture bottles of the BacT", ALERT 3D system used for the detection of pathogens and time to detection, 2015, pp.10, e0116728~
  13. She RC, "Performance of the BacT", Alert Virtuo Microbial Detection System for the culture of sterile body fluids : prospective multicentre study, 2018, pp.24, 992~996
  14. Congestri F, "Comparison of ‘time to detection’ values between BacT", ALERT VIRTUO and BacT, Int J Infect Dis, pp.2017, 62[DOI]
  15. Altun O, "Controlled evaluation of the new BacT", Alert Virtuo blood culture system for detection and time to detection of bacteria and yeasts, 2016, pp.54, 1148~1151
  16. Miller N, "Implementation of the new VIRTUO blood culture system : evaluation and comparison to the 3D system using simulated blood cultures", Acta Clin Belg, 73, pp.16~20 (2018)
  17. Park J, "Comparison of growth performance of the BacT", ALERT VIRTUO and BACTEC FX blood culture systems under simulated bloodstream infection conditions, 2017, pp.63, 39~46
  18. 박상혁, "Clinical Relevance of Time-to-positivity in BACTEC9240 Blood Culture System", Annals of Laboratory Medicine, 30(3), pp.276~283 (2010), 대한진단검사의학회

관련 논문AI추천

Comparison of Blood Culture Parameters between 2 and 10 mL Aerobic Bottles from Patients with Sepsis김선주, 김성춘대한임상미생물학회 · Annals of Clinical Microbiology2021 · 제24권 제3호Growth Dynamics of Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa as a Function of Time to Detection in BacT/Alert 3D Blood Culture Bottles with Various Preincubation Conditions고은하, 김선주, 이동현, 최새롬대한진단검사의학회 · Annals of Laboratory Medicine2013 · 제33권 제6호Comprehensive Analysis of Blood Culture Performed at Nine University Hospitals in Korea구선회, 김미나, 김선주, 김의종, 김재석, 류남희, 송새암, 신정환, 이남용, 조지현대한진단검사의학회 · Annals of Laboratory Medicine2011 · 제31권 제2호Effects of Preincubating Blood Culture Bottles at 37℃ during the Night Shift and of Collected Blood Volume on Time to Detection and Days to Final Report고은하, 김선주대한임상미생물학회 · Annals of Clinical Microbiology2014 · 제17권 제1호Effects of Blood Volume Monitoring on the Rate of Positive Blood Cultures from the Emergency Room김충종, 소민경, 이미애, 정혜선, 최희정대한임상미생물학회 · Annals of Clinical Microbiology2016 · 제19권 제3호Clinical Relevance of Time-to-positivity in BACTEC9240 Blood Culture System김미나, 박상혁, 심효은, 윤남섭대한진단검사의학회 · Annals of Laboratory Medicine2010 · 제30권 제3호

이 간행물의 다른 논문 (15건)