본문 바로가기
KERD
논문KCI 등재

Feasibility of Using the Clamp Meter in Measuring X-Ray Tube Current

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류컴퓨터학

초록

The clamp meter maintains electric safety as a non-invasive method while measuring the absolute value of tube current with it has been recently developed for an X-ray high-tension cable. Especially this can show high accuracy at short X-ray exposure time. Considering such a condition, this study is to evaluate the feasibility of a clamp meter in measuring X-ray tube current by taking the measurements and comparing with those of the Dynalyzer III which has been considered as a standard measuring device. From measuring the tube current accuracy depending on changes in tube voltage and exposure time, the clamp meter showed higher accuracy rate which was -1.3~4.2% difference. Thus clamp meter can be used for clinical radiologists who are not familiar electric circuit to manage X-ray devices easily and correctly in the future.

Abstract

The clamp meter maintains electric safety as a non-invasive method while measuring the absolute value of tube current with it has been recently developed for an X-ray high-tension cable. Especially this can show high accuracy at short X-ray exposure time. Considering such a condition, this study is to evaluate the feasibility of a clamp meter in measuring X-ray tube current by taking the measurements and comparing with those of the Dynalyzer III which has been considered as a standard measuring device. From measuring the tube current accuracy depending on changes in tube voltage and exposure time, the clamp meter showed higher accuracy rate which was -1.3~4.2% difference. Thus clamp meter can be used for clinical radiologists who are not familiar electric circuit to manage X-ray devices easily and correctly in the future.

참고문헌 (13)

  1. S.S. Kang, "Diagnostic X-ray Equipment 2nd ed." (2011), Chung-ku Pub. co.
  2. J.M. Kim, "X-ray Equipment & Management Experiments" (2000), Daihak Pub. co.
  3. R.R. Carlton, "Principles of Radiographic imaging-An art and a science 4th Ed." (2006), Thomson
  4. T.T. Thompson, "A practical Approach to Modern X-ray Equipment" (1978), Brown and co.
  5. 강세식, "인버터식 X선장치의 성능평가 시 비접속형 측정기의 유용성", 방사선기술과학, 31(2), pp.123~128 (2008), 대한방사선과학회
  6. 강병삼, "수도권지역 일반촬영 장비의 정도관리 분석", 방사선기술과학, 35(2), pp.93~102 (2012), 대한방사선과학회[DOI]
  7. I.C. Im, "An ability test for the use of Indirect Radiographic unit", J. of Radiological Science & Technology, 27(4), pp.37~41 (2004)
  8. 박주훈, "병원 규모별 진단용 X선 발생장치의 성능 평가", 방사선방어학회지, 34(1), pp.31~36 (2009), 대한방사선방어학회
  9. 박정규, "경북 지역 의원급의 X선 발생장치 정도관리 실태", 한국콘텐츠학회 논문지, 10(9), pp.267~275 (2010), 한국콘텐츠학회
  10. P. Carter, "Chesneys' Equipment for Student Radiographers 4th Ed.", pp.64~76 (1994), Blackwell scientific Pub.
  11. J.D. Ramboz, "A Highly Accurate hand-held Clamp-on Current Transformer", IEEE trans. Instrum., 45(2), pp.445~448 (1996)
  12. E. So, "A low-current Multistage Clampon Current Transformer with Ratio errors below 50 ppm", IEEE trans. Instrum., 46(2), pp.454~458 (1997)
  13. Y.M. chang, "Development of Clamp Current Meter using a Flexible Rogowski coil", Kieeme J. of Annual autumn conferen, pp.472~475 (2002)

관련 논문AI추천