인터벤션 방사선발생장치에서 입사표면선량률 평가
Evaluation of Radiation Entrance Surface Dose Rates for Interventional Radiology Equipment
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
IVR procedures are on the rise, and patient doses are on the rise. It is necessary to evaluate fluoroscopy dose in IVR procedure. Evaluate ESD on IVR equipment as a reference to DRL settings, I would like to present the direction of improvement in the ESD rate test criteria for fluoroscopy dose. The experimental method is measured with 6cc ionization chamber under the 20cm PMMA Phantom. Radiation is subject to abdominal procedure. The average dose rate of the incident surface was 21.6 ± 11.4 mGy/min. The highest dose equipment was 58.5 mGy/min, and there was no equipment exceeding the domestic standard of 100 mGy/min. However, there were five units above 50 mGy/min. To reduce fluoroscopy dose, it is recommended to reduce pulse rate, The dose increases as the image receptor ages. It is recommended to modify the domestic inspection criteria to 50 mGy/min.
Abstract
IVR procedures are on the rise, and patient doses are on the rise. It is necessary to evaluate fluoroscopy dose in IVR procedure. Evaluate ESD on IVR equipment as a reference to DRL settings, I would like to present the direction of improvement in the ESD rate test criteria for fluoroscopy dose. The experimental method is measured with 6cc ionization chamber under the 20cm PMMA Phantom. Radiation is subject to abdominal procedure. The average dose rate of the incident surface was 21.6 ± 11.4 mGy/min. The highest dose equipment was 58.5 mGy/min, and there was no equipment exceeding the domestic standard of 100 mGy/min. However, there were five units above 50 mGy/min. To reduce fluoroscopy dose, it is recommended to reduce pulse rate, The dose increases as the image receptor ages. It is recommended to modify the domestic inspection criteria to 50 mGy/min.
참고문헌 (15)
- Kinney TB, "Radiographic history exhibit, Charles T. Dotter: A pioneering interventional Radiologist", Radiographics, 16, pp.697~707 (1996)
- "ICRP 60. Recommendations of the International Commission on Radiological Protection", ~ (1990)
- Ruiz-Cruces R, "Diagnostic reference levels and complexity indices in interventional radiology : A national programme", Eur Radiol, 26(12), pp.4268~4276 (2016)
- "ICRP 85. Avoidance of Radiation Injuries from Medical Interventional Procedures", ~ (2000)
- Valentin J, "Avoidance of radiation injuries from medical interventional procedures", Ann ICRP, 30, pp.7~67 (2000)
- "ICRP 103. Recommendations of the International Commission on Radiological Protection", ~ (2007)
- Evaluation of patient doses from interventional radiology procedures, "Chung JW", KFDA, ~ (2012)
- Development of the diagnostic reference level in interventional radiology:11 interventional procedures, "Jae HJ", KDCA, ~ (2019)
- "ICRP 135. Diagnostic Reference Levels(DRLs) in Medical Imaging", ~ (2017)
- Streker MS, "Guidelines for patient radiation dose management", J Vasc Interv Radiol, 20, pp.263~273 (2009)
- 강병삼, "인터벤션 시술 시 면적선량계를 이용한 환자 방사선 선량 평가", 방사선기술과학, 40(1), pp.27~34 (2017), 대한방사선과학회[DOI]
- 손진현, "진단영역 X선 에너지에서 유리선량계, 반도체선량계, 면적선량계의 선량 실측 비교", 방사선기술과학, 42(6), pp.483~489 (2019), 대한방사선과학회
- 전미은, "방사선 중재적 시술 중 시술자의 피폭선량에 대한 연구", 방사선기술과학, 35(3), pp.219~226 (2012), 대한방사선과학회
- Ichida T., "Japanese culture for me and japanese IVR in the world", The 76th Annual Meeting of the JSRT (2020)
- Watanabe H, "Report of a nation wide survey on actual administered radioactivities of radiopharmaceuticals for diagnostic reference levels in Japan", Ann Nucl Med, 30(6), pp.435~444 (2016)