다양한 유사체액과 인공타액에서 치과용 임플란트의 전기화학적 특성

Electrochemical Characteristics of Dental Implant in the Various Simulated Body Fluid and Artificial Saliva

2

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류기계공학

초록

Titanium and its alloy have been widely used in dental implant and orthopedic prostheses. Electrochemical characteristics of dental implant in the various simulated body fluids have been researched by using electrochemical methods. Ti-6Al-4V alloy implant was used for corrosion test in 0.9% NaCl, artificial saliva and simulated body fluids. The surface morphology was observed using scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX). The electrochemical stability was investigated using potentiosat (EG&G Co, 263A). The corrosion surface was observed using scanning electron microscopy (SEM). From the results of potentiodynamic test in various solution, the current density of implant tested in SBF and AS solution was lower than that of implant tested in 0.9% NaCl solution. From the results of passive film stability test, the variation of current density at constant 250 mV showed the consistent with time in the case of implant tested in SBF and AS solution, whereas, the current density at constant 250mV in the case of implant tested in 0.9% NaCl solution showed higher compared to SBF and AS solution as time increased. From the results of cyclic potentiodynamic test, the pitting potential and |Epit-Ecorr| of implant tested in SBF and AS solution were higher than those of implant tested in 0.9% NaCl solution.

Abstract

Titanium and its alloy have been widely used in dental implant and orthopedic prostheses. Electrochemical characteristics of dental implant in the various simulated body fluids have been researched by using electrochemical methods. Ti-6Al-4V alloy implant was used for corrosion test in 0.9% NaCl, artificial saliva and simulated body fluids. The surface morphology was observed using scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX). The electrochemical stability was investigated using potentiosat (EG&G Co, 263A). The corrosion surface was observed using scanning electron microscopy (SEM). From the results of potentiodynamic test in various solution, the current density of implant tested in SBF and AS solution was lower than that of implant tested in 0.9% NaCl solution. From the results of passive film stability test, the variation of current density at constant 250 mV showed the consistent with time in the case of implant tested in SBF and AS solution, whereas, the current density at constant 250mV in the case of implant tested in 0.9% NaCl solution showed higher compared to SBF and AS solution as time increased. From the results of cyclic potentiodynamic test, the pitting potential and |Epit-Ecorr| of implant tested in SBF and AS solution were higher than those of implant tested in 0.9% NaCl solution.

참고문헌 (15)

  1. J. E. Davies, , J. Biomed Mat. Res, 24, pp.1289~ (1990)
  2. M. Therin, , J. Mat. Sci. Mat. in Med, 2, pp.1~ (1991)
  3. D. Krupa, , Biomaterials, 22, pp.2139~ (2001)
  4. H. Brauner, , Surf Coat Technol, 62, pp.618~ (1993)
  5. E. Giglio, , Biomaterials, 22, pp.2609~ (2001)
  6. K. Groot, , J. Biomed Mater. Res, 21, pp.1375~ (1987)
  7. T. Hanawa, , Corros. Sci, 38, pp.1579~ (1996)
  8. 최한철, "임상에서 실패된 치과 임플란트 고정체의 표면 분석", 대한금속·재료학회지, 44(06), pp.400~411 (2006), 대한금속ㆍ재료학회
  9. D. Buser, , Stich. J. Biomed Mater. Res, 25, pp.889~ (1991)
  10. Han Cheol Choe, "Analyses of Fractured Implant Fixture after Prolonged Implantation", Metals and Materials International, 10(4), pp.327~335 (2004), 대한금속·재료학회
  11. Myung-Ju Han, "Surface Characteristics of Clinically Used Dental Implant Screws", Metals and Materials International, 11(6), pp.449~456 (2005), 대한금속·재료학회
  12. H. C. Choe, , Surface & Coatings Tech, 148, pp.77~ (2001)
  13. D. A. Jones, "Principles and prevention of corrosion", pp.243~ (1992), Maxwell Macmillan international editions
  14. Han-Cheol Choe, "Corrosion Behavior between Dental Implant Abutment and Cast Gold Alloy", Metals and Materials International, 10(2), pp.153~159 (2004), 대한금속·재료학회
  15. C. Li, , Materials Science & Eng, A 438-440, pp.504~ (2006)

관련 논문AI추천

이 간행물의 다른 논문 (10건)