본문 바로가기
KERD
논문KCI 등재

골아세포가 배양된 치과 임플란트용 Ti-Ta합금의 전기화학적 특성

Electrochemical Characteristics of Osteoblast Cultured Ti-Ta Alloy for Dental Implant

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류기계공학

초록

Electrochemical behaviors of surface modified and MC3T3-E1 cell cultured Ti-30Ta alloys have been investigated using various electrochemical methods. The Ti alloys containing Ta were melted by using a vacuum furnace and then homogenized for 6 hrs at 1000oC. MC3T3-E1 cell culture was performed with MC3T3-E1 mouse osteoblasts for 2 days. The microstructures and corrosion resistance were measured using FE-SEM, XRD, EIS and potentiodynamic test in artificial saliva solution at 36.5℃. Ti-Ta alloy showed the martensite structure of a+b phase and micro-structure was changed from lamellar structure to needle-like structure as Ta content increased.Corrosion resistance increased as Ta content increased. Corrosion resistance of cell cultured Ti-Ta alloy increased predominantly in compared with non cell cultured Ti-Ta alloy due to inhibition of the dissolution of metal ion by covered cell. Rp value of MC3T3-E1 cell cultured Ti-40 Ta alloy showed 1.60106 Wcm2 which was higher than those of other Ti alloy. Polarization resistance of cell-cultured Ti-Ta alloy increased in compared with non-cell cultured Ti alloy.

Abstract

Electrochemical behaviors of surface modified and MC3T3-E1 cell cultured Ti-30Ta alloys have been investigated using various electrochemical methods. The Ti alloys containing Ta were melted by using a vacuum furnace and then homogenized for 6 hrs at 1000oC. MC3T3-E1 cell culture was performed with MC3T3-E1 mouse osteoblasts for 2 days. The microstructures and corrosion resistance were measured using FE-SEM, XRD, EIS and potentiodynamic test in artificial saliva solution at 36.5℃. Ti-Ta alloy showed the martensite structure of a+b phase and micro-structure was changed from lamellar structure to needle-like structure as Ta content increased.Corrosion resistance increased as Ta content increased. Corrosion resistance of cell cultured Ti-Ta alloy increased predominantly in compared with non cell cultured Ti-Ta alloy due to inhibition of the dissolution of metal ion by covered cell. Rp value of MC3T3-E1 cell cultured Ti-40 Ta alloy showed 1.60106 Wcm2 which was higher than those of other Ti alloy. Polarization resistance of cell-cultured Ti-Ta alloy increased in compared with non-cell cultured Ti alloy.

참고문헌 (24)

  1. M. Niinomi, , Mater. Sci. Eng, 243, pp.231~ (1998)
  2. J. E. Davies, , J. Biomed Mat. Res, 24, pp.1289~ (1990)
  3. M. Therin, , J. Mat. Sci. Mat. in Med, 2, pp.1~ (1991)
  4. N. R. Van, , J. Mater. Sci, 22, pp.3801~ (1987)
  5. E. Kobayashi, , J. Prosthet Dent, 54, pp.410~ (1985)
  6. M. F. Semlitsch, , Biomaterials, 13, pp.781~ (1992)
  7. Y. Okazaki, , J. Japan Inst. Metals, 9, pp.890~ (1996)
  8. A. K. Shukla, , J. Alloys Comp, 389, pp.144~ (2005)
  9. D. Kuroda, , Materials Sci. and Eng, A 243, pp.244~ (2001)
  10. Y. L. Zhou, , Materials Sci. and Eng, A 384, pp.92~ (2004)
  11. Y. L. Zhou, , Materials Sci. and Eng, A 371, pp.283~ (2004)
  12. Y. L. Zhou, , Materials Sci. and Eng, A 398, pp.28~ (2005)
  13. S. G. Fedotov, , pp.29~ (1982), Nauka
  14. S. G. Fedotov, , pp.78~ (1982), Nauka
  15. G. I. Nosova, (1968), Nauka
  16. E. W. Collings, (1986), ASM
  17. R. Boyer, "Titanium Alloys" (1994), ASMI
  18. K. Anselme, , Biomaterials, 21, pp.1567~ (2000)
  19. M. Bigerelle, , A Iost. Biomaterials, 23, pp.1563~ (2002)
  20. P. Linez-Bataillon, , Biomolecular Engineering, 19, pp.133~ (2002)
  21. N. Ibris, , Journal of Electroanalytical Chemistry, 52, pp.653~ (2002)
  22. J. E. G. Gonzalez, , Journal of Electroanalytical Chemistry, 471, pp.109~ (1999)
  23. E. Kobayashi, , Mater. Sci.: Mater. Med, 9, pp.567~ (1998)
  24. D. Krupa, , Biomaterials, 22, pp.2139~ (2001)