Atomic force microscopy (AFM) has been used for imaging surfaces and measuring surface forces at the nano-scale. Force calibration is important for the quantitative measurement of forces at the nano-scale using AFM. Normal force calibration is relatively straightforward, whereas the lateral force calibration is more complicated since the lateral stiffness of the cantilever is often comparable to the contact stiffness. In this work, the lateral force calibrations of the rectangular cantilever were performed using torsional Sader’s method, thermal noise method, and wedge calibration method. The lateral optical lever sensitivity for the thermal noise method was determined from the friction loop under various normal forces as well. Experimental results showed that the discrepancies among the results of the different methods were as large as 30% due to the effect of the contact stiffness on the lateral force calibration of the cantilever used in this work. After correction for the effect of contact stiffness, all the calibration results agreed with each other, within experimental uncertainties.
Abstract
Atomic force microscopy (AFM) has been used for imaging surfaces and measuring surface forces at the nano-scale. Force calibration is important for the quantitative measurement of forces at the nano-scale using AFM. Normal force calibration is relatively straightforward, whereas the lateral force calibration is more complicated since the lateral stiffness of the cantilever is often comparable to the contact stiffness. In this work, the lateral force calibrations of the rectangular cantilever were performed using torsional Sader’s method, thermal noise method, and wedge calibration method. The lateral optical lever sensitivity for the thermal noise method was determined from the friction loop under various normal forces as well. Experimental results showed that the discrepancies among the results of the different methods were as large as 30% due to the effect of the contact stiffness on the lateral force calibration of the cantilever used in this work. After correction for the effect of contact stiffness, all the calibration results agreed with each other, within experimental uncertainties.
참고문헌 (24)
- Binnig, G., "Atomic Force Microscope", Phys Rev Lett, 56, pp.930~933 (1986)
- 정구현, "Nanomechanical Properties of Thin Films of Type I Collagen Fibrils", LANGMUIR, 26(5), pp.3629~3636, AMER CHEMICAL SOC
- Mahaffy, R. E., "Scanning Probe-Based Frequency-Dependent Microrheology of Polymer Gels and Biological Cells", Phys Rev Lett, 85, pp.880~883 (2000)
- Stan, G., "Ultimate Bending Strength of Si Nanowires", Nano Lett., 12, pp.2599~2604 (2012)
- Giesbers, A. J. M., "Nanolithography and Manipulation of Graphene using an Atomic Force Microscope", Solid State Commun, 147, pp.366~369 (2008)
- Hutter, J. L., "Calibration of Atomic-Force Microscope Tips", Rev. Sci. Instrum., 64, pp.1868~1873 (1993)
- Sader, J. E., "Calibration of Rectangular Atomic Force Microscope Cantilevers", Rev. Sci. Instrum., 70, pp.3967~3969 (1999)
- Higgins, M. J., "Noninvasive Determination of Optical Lever Sensitivity in Atomic Force Microscopy", Rev. Sci. Instrum., 77, pp.013701~ (2006)
- Wagner, K., "Noncontact Method for Calibration of Lateral Forces in Scanning Force Microscopy", Langmuir, 27, pp.4635~4644 (2011)
- Torii, A., "A Method for Determining the Spring Constant of Cantilevers for Atomic Force Microscopy", Meas Sci Technol, 7, pp.179~184 (1996)
- Gates, R. S., "Precise Atomic Force Microscope Cantilever Spring Constant Calibration using a Reference Cantilever Array", Rev. Sci. Instrum., 78, pp.086101~ (2007)
- Cleveland, J. P., "A Nondestructive Method for Determining the Spring Constant of Cantilevers for Scanning Force Microscopy", Rev. Sci. Instrum., 64, pp.403~405 (1993)
- Chung, K. H., "Accurate Noncontact Calibration of Colloidal Probe Sensitivities in Atomic Force Microscopy", Rev. Sci. Instrum., 80, pp.065107~ (2009)
- Cain, R. G., "Force Calibration in Lateral Force Microscopy", J. Colloid Interface Sci., 227, pp.55~65 (2000)
- Sader, J. E., "In-Plane Deformation of Cantilever Plates with Applications to Lateral Force Microscopy", Rev. Sci. Instrum., 75, pp.878~883 (2004)
- Cannara, R. J., "Lateral Force Calibration in Atomic Force Microscopy: A New Lateral Force Calibration Method and General Guidelines for Optimization", Rev. Sci. Instrum., 77, pp.053701~ (2006)
- Ogletree, D. F., "Calibration of Frictional Forces in Atomic ForceMicroscopy", Rev. Sci. Instrum., 67, pp.3298~3306 (1996)
- Varenberg, M., "An Improved Wedge Calibration Method for Lateral Force in Atomic Force Microscopy", Rev. Sci. Instrum., 74, pp.3362~3367 (2003)
- Li, Q., "Lateral Force Calibration of an Atomic Force Microscope with a Diamagnetic Levitation Spring System", Rev. Sci. Instrum., 77, pp.065105~ (2006)
- Chung, K. H., "Note: Lateral Force Microscope Calibration using Multiple Location Pivot Loading of Rectangular Cantilevers", Rev. Sci. Instrum., 81, pp.026104~ (2010)
- Wang, F., "Effect of Contact Stiffness on Wedge Calibration of Lateral Force in Atomic Force Microscopy", Rev. Sci. Instrum., 78, pp.043701~ (2007)
- Green, C. P., "Normal and Torsional Spring Constants of Atomic Force Microscope Cantilevers", Rev. Sci. Instrum., 75, pp.1988~1996 (2004)
- Sader, J. E., "Frequency Response of Cantilever Beams Immersed in Viscous Fluids with Applications to the Atomic Force Microscope", J. Appl. Phys., 84, pp.64~76 (1998)
- Carpick, R. W., "Lateral Stiffness: A New Nanomechanical Measurementfor the Determination of Shear Strengths withFriction Force Microscopy", Appl. Phys. Lett., 70, pp.1548~1550 (1997)