본문 바로가기
KERD
논문KCI 등재

AFM을 이용한 나노스케일 힘의 정량적 측정

Quantitative Measurement of Nano-scale Force using Atomic Force Microscopy

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류기계공학

초록

Atomic force microscopy (AFM) has been widely utilized as a versatile tool not only for imaging surfaces but also for understanding nano-scale interfacial phenomena. By measuring the responses of the photo detector due to bending and torsion of the cantilever, which are caused by the interactions between the probe and the sample surface, various interfacial phenomena and properties can be explored. One of the challenges faced by AFM researchers originates in the physics of measuring the small forces that act between the probe of a force sensing cantilever and the sample. To understand the interactions between the probe and the sample quantitatively,the force calibration is essential. In this work, the procedures used to calibrate AFM instrumentation for nano-scale force measurement in normal and lateral directions are reviewed.

Abstract

Atomic force microscopy (AFM) has been widely utilized as a versatile tool not only for imaging surfaces but also for understanding nano-scale interfacial phenomena. By measuring the responses of the photo detector due to bending and torsion of the cantilever, which are caused by the interactions between the probe and the sample surface, various interfacial phenomena and properties can be explored. One of the challenges faced by AFM researchers originates in the physics of measuring the small forces that act between the probe of a force sensing cantilever and the sample. To understand the interactions between the probe and the sample quantitatively,the force calibration is essential. In this work, the procedures used to calibrate AFM instrumentation for nano-scale force measurement in normal and lateral directions are reviewed.

참고문헌 (38)

  1. Binnig, G., "Atomic Force Microscope", Phys. Rev. Lett., 56, pp.930~933 (1986)
  2. Mamin, H. J., "Thermomechanical Writing with an Atomic Force Microscope Tip", Appl. Phys. Lett., 61, pp.1003~1005 (1992)
  3. 김대은, "Micro", nano-tribological characteristics of self-assembled monolayer and its application in nano-structure fabrication, 200308, pp.255, 808~818[DOI]
  4. Erlandsson, R., "Atomic Force Microscopy Using Optical Interferometry", J. Vac. Sci. Technol. A, 6, pp.266~270 (1988)
  5. 이창구, "Measurement of the elastic properties and intrinsic strength of monolayer graphene", SCIENCE, 321(5887), pp.385~388, AMER ASSOC ADVANCEMENT SCIENCE
  6. Dae-Eun Kim, "Nano-Mechanical and Tribological Characteristics of Ultra- Thin Amorphous Carbon Film Investigated by AFM", Journal of Mechanical Science and Technology, 18(10), pp.1772~1781 (2004), 대한기계학회
  7. Thundat, T., "Stretched DNA Structures Observed with Atomic Force Microscopy", Nucleic Acids Res., 22, pp.4224~4228 (1994)
  8. Mahaffy, R. E., "Scanning Probe-Based Frequency-Dependent Microrheology of Polymer Gels and Biological Cells", Phys. Rev. Lett, 85, pp.880~883 (2000)
  9. 정구현, "Nanomechanical Properties of Thin Films of Type I Collagen Fibrils", LANGMUIR, 26(5), pp.3629~3636, AMER CHEMICAL SOC
  10. Guthold, M., "Visualization and Mechanical Manipulations of Individual Fibrin Fibers Suggest that Fiber Cross Section Has Fractal Dimension 1. 3", Biophys. J., 87, pp.4226~4236 (2004)
  11. Cleveland, J. P., "A Nondestructive Method for Determining the Stiffness of Cantilevers for Scanning Force Microscopy", Rev. Sci. Instrum., 64, pp.403~405 (1995)
  12. Cain, R. G., "Force Calibration in Lateral Force Microscopy", J. Colloid Interface Sci., 227, pp.55~65 (2001)
  13. Pratt, J. R., "Progress toward Système International d'Unités traceable force metrology for nanomechanics", J. Mater. Res., 19, pp.366~379 (2004)
  14. Ogletree, D. F., "Calibration of Frictional Forces in Atomic Force Microscopy", Rev. Sci. Instrum., 67, pp.3298~3306 (1996)
  15. Higgins, M. J., "Noninvasive Determination of Optical Lever Sensitivity in Atomic Force Microscopy", Rev. Sci. Instrum, 77, pp.013701~ (2006)
  16. Wagner, K., "Noncontact Method for Calibration of Lateral Forces in Scanning Force Microscopy", Langmuir, 27, pp.4635~4644 (2011)
  17. Chung, K. -H., "Accurate Noncontact Calibration of Colloidal Probe Sensitivities in Atomic Force Microscopy Using Electrostatics", Rev. Sci. Instrum, 80, pp.065107~ (2009)
  18. Cannara, R. J., "Lateral Force Calibration in Atomic Force Microscopy : A New Lateral Force Calibration Method and General Guidelines for Optimization", Rev. Sci. Instrum., 77, pp.053701~ (2006)
  19. Craig, V.S.J., "In Situ Calibration of Colloid Probe Cantilevers in Force Microscopy : Hydrodynamic Drag on a Sphere Approaching a Wall", Langmuir, 17, pp.6018~6022 (2001)
  20. Sader, J. E., "Parallel Beam Approximation for Vshaped Atomic Force Microscope Cantilevers", Rev. Sci. Instrum., 66, pp.4583~4587 (1995)
  21. Hutter, J.L., "Calibration of Atomic Force Microscope Tips", Rev. Sci. Instrum., 6, pp.1868~1873 (1993)
  22. Butt, H.-J., "Calculation of Thermal Noise in Atomic Force Microscopy", Nanotechnol., 6, pp.1~7 (1995)
  23. Proksch, R., "Finite Optical Spot Size and Position Corrections in Thermal Spring Constant Calibration", Nanotechnol., 15, pp.1344~1350 (2004)
  24. Heim, L. -O., "Tilt of Atomic Force Microscope Cantilevers: Effect on Spring Constant and Adhesion Measurements", Langmuir, 20, pp.2760~2764 (2004)
  25. Sader, J. E., "Calibration of Rectangular Atomic Force Microscope Cantilevers", Rev. Sci. Instrum., 70, pp.3967~3969 (1999)
  26. 김대은, "Characteristics of fracture during the approach process and wear mechanism of a silicon AFM tip", ULTRAMICROSCOPY, 102, pp.161~171, ELSEVIER SCIENCE BV
  27. Torii, A., "A Method for Determining the Spring Constant of Cantilevers for Atomic Force Microscopy", Meas. Sci. Technol., 7, pp.179~184 (1996)
  28. Gates, R.S., "Precise Atomic Force Microscope Cantilever Spring Constant Calibration using a Reference Cantilever Array", Rev. Sci. Instrum., 78, pp.086101~ (2007)
  29. Sader, J.E., "In-plane Deformation of Cantilever Plates with Applications to Lateral Force Microscopy", Rev. Sci. Instrum., 75, pp.878~883 (2004)
  30. Green, C. P., "Normal and Torsional Spring Constants of Atomic Force Microscope Cantilevers", Rev. Sci. Instrum., 75, pp.1988~1996 (2004)
  31. Feiler, A., "Calibration of the Torsional Spring Constants and the Lateral Photodiode Response of Frictional Force Microscopes", Rev. Sci. Instrum., 71, pp.2746~2750 (2000)
  32. Chung K.-H., "Lateral Force Microscope Calibration using Multiple Location Pivot Loading of Rectangular Cantilevers", Rev. Sci. Instrum., 81, pp.026104~ (2010)
  33. Xie, H., "Calibration of Lateral Force Measurements in Atomic Force Microscopy with a Piezoresistive Force Sensor", Rev. Sci. Instrum., 79, pp.033708~ (2008)
  34. Li, Q., "Lateral Force Calibration of an Atomic Force Microscope with a Diamagnetic Levitation Spring System", Rev. Sci. Instrum., 77, pp.065105~ (2006)
  35. Wang, F., "Effect of Contact Stiffness on Wedge Calibration of Lateral Force in Atomic Force Microscopy", Rev. Sci. Instrum., 78, pp.043701~ (2007)
  36. Varenberg, M., "An Improved Wedge Calibration Method for Lateral Force in Atomic Force Microscopy", Rev. Sci. Instrum., 74, pp.3362~3367 (2003)
  37. Reitsma, M. G., "Prototype Cantilevers for Quantitative Lateral Force Microscopy", Rev. Sci. Instrum, 82, pp.093706~ (2011)
  38. Chung, K. -H., "Lateral Force Calibration: Accurate Procedures for Colloidal Probe Friction Measurements in Atomic Force Microscopy", Langmuir, 26, pp.1368~1394 (2010)

관련 논문AI추천

이 간행물의 다른 논문 (5건)