본문 바로가기
KERD
논문KCI 등재

The effects of saline soaking on the removal torque of titanium implants in rabbit tibia after 10 days

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Purpose: The aim of this study was to confirm if Laser-treated implants were soaked in 0.9% NaCl solution for 2 weeks could increase the surface hydrophilicity, and the Remoal Torque of each implant that inserted in rabbit tibia for initial healing period of 10 days. Materials and methods: Twenty machined titanium surface screws were produced with a diameter 3 mm, length 8 mm. Ten screws had their surface treated with a laser only (laser treated group), and the other 10 were soaked in saline for 2 weeks after surface treatment with a laser (laser treated + saline soaked group). Implants were inserted in rabbit tibia (ten adult New Zealand white rabbits), and the RTQ of each implant was measured after 10 days. The wettability among implants was compared by measuring the contact angle. Surface composition and surface topography were analyzed. Results: After 10 days, the laser treat + soaking group implants had a significantly higher mean RTQ than the laser treated implants (P = .002, < .05). There were no significant morphological differences between groups, and no remarkable differences were found between the two groups in the SEM analysis. Conclusion: Saline soaking implants is expected to produce excellent RTQ and surface analysis results.

Abstract

Purpose: The aim of this study was to confirm if Laser-treated implants were soaked in 0.9% NaCl solution for 2 weeks could increase the surface hydrophilicity, and the Remoal Torque of each implant that inserted in rabbit tibia for initial healing period of 10 days. Materials and methods: Twenty machined titanium surface screws were produced with a diameter 3 mm, length 8 mm. Ten screws had their surface treated with a laser only (laser treated group), and the other 10 were soaked in saline for 2 weeks after surface treatment with a laser (laser treated + saline soaked group). Implants were inserted in rabbit tibia (ten adult New Zealand white rabbits), and the RTQ of each implant was measured after 10 days. The wettability among implants was compared by measuring the contact angle. Surface composition and surface topography were analyzed. Results: After 10 days, the laser treat + soaking group implants had a significantly higher mean RTQ than the laser treated implants (P = .002, < .05). There were no significant morphological differences between groups, and no remarkable differences were found between the two groups in the SEM analysis. Conclusion: Saline soaking implants is expected to produce excellent RTQ and surface analysis results.

참고문헌 (23)

  1. Parithimarkalaignan S, "Osseointegration : An update", J Indian Prosthodont Soc, 13, pp.2~6 (2013)
  2. Cooper LF, "A role for surface topography in creating and maintaining bone at titanium endosseous implants", J Prosthet Dent, 84, pp.522~534 (2000)
  3. Wennerberg A, "Nanostructures and hydrophilicity influence osseointegration : a biomechanical study in the rabbit tibia", Clin Oral Implants Res, 25, pp.1041~1050 (2014)
  4. Anil S, "Dental implant surface enhancement and osseointegration", pp.83~108 (2011), In Tech
  5. Cho SA, "A removal torque of the laser-treated titanium implants in rabbit tibia", Biomaterials, 24, pp.4859~4863 (2003)
  6. Berglundh T, "De novo alveolar bone formation adjacent to endosseous implants", Clin Oral Implants Res, 14, pp.251~262 (2003)
  7. Wennerberg A, "Effects of titanium surface topography on bone integration : a systematic review", Clin Oral Implants Res, 20, pp.172~184 (2009)
  8. Sittig C, "Surface characterization of implant materials c.p. Ti, Ti-6Al-7Nb and Ti-6Al-4V with different pretreatments", J Mater Sci Mater Med, 10, pp.35~46 (1999)
  9. Massaro C, "Comparative investigation of the surface properties of commercial titanium dental implants. Part I: chemical composition", J Mater Sci Mater Med, 13, pp.535~548 (2002)
  10. Le Guéhennec L, "Surface treatments of titanium dental implants for rapid osseointegration", Dent Mater, 23, pp.844~854 (2007)
  11. Rupp F, "Wetting behavior of dental implants", Int J Oral Maxillofac Implants, 26, pp.1256~1266 (2011)
  12. Zhao G, "High surface energy enhances cell response to titanium substrate microstructure", J Biomed Mater Res A, 74, pp.49~58 (2005)
  13. Sartoretto SC, "Early osseointegration driven by the surface chemistry and wettability of dental implants", J Appl Oral Sci, 23, pp.279~287 (2015)
  14. Elias CN, "Implant dentistry: a rapidly evolving practice", pp.319~364 (2011), InTech
  15. Weber HP, "Consensus statements and recommended clinical procedures regarding loading protocols", Int J Oral Maxillofac Implants, 24, pp.180~183 (2009)
  16. 권재욱, "토끼의 경골에서 RBM 표면처리 임플란트와 RBM 표면처리 후 Saline에 적신 임플란트의 제거회전력 및 표면분석 비교", 대한치과보철학회지, 56(1), pp.1~7 (2018), 대한치과보철학회[DOI]
  17. Sela MN, "Adsorption of human plasma proteins to modified titanium surfaces", Clin Oral Implants Res, 18, pp.630~638 (2007)
  18. Buser D, "Enhanced bone apposition to a chemically modified SLA titanium surface", J Dent Res, 83, pp.529~533 (2004)
  19. Donos N, "Gene expression profile of osseointegration of a hydrophilic compared with a hydrophobic microrough implant surface", Clin Oral Implants Res, 22, pp.365~372 (2011)
  20. Ivanoff CJ, "Influence of monoand bicortical anchorage on the integration of titanium implants. A study in the rabbit tibia", Int J Oral Maxillofac Surg, 25, pp.229~235 (1996)
  21. Albrektsson T, "Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man", Acta Orthop Scand, 52, pp.155~170 (1981)
  22. Textor M, "Titanium in medicine: material science, surface science, engineering, biological responses and medical applications", pp.171~230 (2001), Springer
  23. Lang NP, "Early osseointegration to hydrophilic and hydrophobic implant surfaces in humans", Clin Oral Implants Res, 22, pp.349~356 (2011)

관련 논문AI추천

Comparison of removal torques between laser-etched and modified sandblasted acid-etched Ti implant surfaces in rabbit tibias박경순, 조성암, Abdel Ghani Ibrahim Al Awamleh대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제1호Comparison of removal torques between laser-treated and SLAtreated implant surfaces in rabbit tibiae강남석, 이인제, 조성암대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제4호Comparison of removal torque of dual-acid etched and single-acid etched implants in rabbit tibias김종진, 조성암대한치과보철학회 · 대한치과보철학회지2019 · 제57권 제4호Comparison of the removal torque and a histomorphometric evaluation of the RBM treated implants with the RBM followed by laser treated implants: an experimental study in rabbits김은경, Eun Young Park, Hae Ok Sohn영남대학교 의과대학 · Journal of Yeungnam Medical Science2019 · 제36권 제1호Biomechanical evaluation of dental implants with different surfaces: Removal torque and resonance frequency analysis in rabbits고정우, 김성훈, 양재호, 이재봉, 한중석대한치과보철학회 · The Journal of Advanced of Prosthodontics2009 · 제1권 제2호Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model김지현, 김현덕, 손영탁, 이규복, 이재목, 이종훈, 전만식, 조호성, 진명욱, 황준호, 손큰바다, Sm Abu Saleah대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제2호

이 간행물의 다른 논문 (22건)