Minimal Electrocautery as an Alternative Approach for Implant Removal: A Preliminary Animal Study
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: This study aimed to introduce electrocautery for failed implant fixtures removal and to compare the results of this technique according to electrocautery time. Materials and Methods: Implants were placed in the femoral condyle of 12-week-old male New Zealand white rabbits. Five implants in three rabbits were used as the experimental group, and two implants in one rabbit were used as the control group. Six weeks later, electrocautery was performed at 30 W for 10 sec and 15 sec in the experimental group, whereas electrocautery was not performed in the control group. One week later, the implants were removed by hand wrench, and histological analysis was performed. Results: At six weeks after implant placement, histological analysis confirmed osseointegration of the fixtures. As a result of electrocautery, the removal torque of implant fixtures was reduced, and osseointegration broke down. There was no difference in the histologic images of the specimens after removal of the fixture between the experimental and control groups. Conclusion: This study showed that minimal electrocautery with low output for a short time can be utilized for implant removal with minimal damage to the surrounding bone.
Abstract
Purpose: This study aimed to introduce electrocautery for failed implant fixtures removal and to compare the results of this technique according to electrocautery time. Materials and Methods: Implants were placed in the femoral condyle of 12-week-old male New Zealand white rabbits. Five implants in three rabbits were used as the experimental group, and two implants in one rabbit were used as the control group. Six weeks later, electrocautery was performed at 30 W for 10 sec and 15 sec in the experimental group, whereas electrocautery was not performed in the control group. One week later, the implants were removed by hand wrench, and histological analysis was performed. Results: At six weeks after implant placement, histological analysis confirmed osseointegration of the fixtures. As a result of electrocautery, the removal torque of implant fixtures was reduced, and osseointegration broke down. There was no difference in the histologic images of the specimens after removal of the fixture between the experimental and control groups. Conclusion: This study showed that minimal electrocautery with low output for a short time can be utilized for implant removal with minimal damage to the surrounding bone.
참고문헌 (7)
- Moraschini V, "Evaluation of survival and success rates of dental implants reported in longitudinal studies with a follow-up period of at least 10 years : a systematic review", Int J Oral Maxillofac Surg, 44, pp.377~388 (2015)
- Stajcic Z, "Removal of dental implants : review of five different techniques", Int J Oral Maxillofac Surg, 45, pp.641~648 (2016)
- Cunliffe J, "Removal of a dental implant : An unusual case report", J Dent Implant, 1, pp.22~25 (2011)
- 박세진, "Removal of Dental Implants using Electrocautery: A Preliminary Report", 대한구강악안면임플란트학회지, 23(4), pp.196~204 (2019), 대한구강악안면임플란트학회[DOI]
- Eriksson AR, "Temperature threshold levels for heat-induced bone tissue injury : a vital-microscopic study in the rabbit", J Prosthet Dent, 50, pp.101~107 (1983)
- Krejci RF, "Effects of electrosurgery on dog pulps under cervical metallic restorations", Oral Surg Oral Med Oral Pathol, 54, pp.575~582 (1982)
- Zach L, "Pulp response to externally applied heat", Oral Surg Oral Med Oral Pathol, 19, pp.515~530 (1965)
