This study was to quantitatively evaluate periodic and maximum energy loads for broiler-standard design models by the Ministry of Agriculture, Foodand Rural Affairs (2016). Building energy simulation method was used to compute heating and cooling loads of the designed broiler houses accordingto regional locations and insulation characteristics of wall and roof. It considered sensible and latent heat generation from broilers, dynamic operationof ventilation system according to environment variations. It was found that variation of periodic heating loads was relatively higher than that of periodiccooling loads according to thickness changes of wall and roof. Assuming that broiler was raised at every even-month, periodic heating and cooling loadswere 6 and 18% lower, respectively than odd-month raising condition. When recommendation rules of insulation characteristics (wall and roof thickness)by the Ministry of Land, Infrastructure and Transport was adopted, periodic heating load of Jeju-si was 20.3% higher than national average values. Based on the BES computed periodic and maximum energy loads under the designed experimental condition, these results can contribute toreestablishing standard design of broiler houses, especially for insulation characteristics, and designing management strategies for efficient energy uses.
Abstract
This study was to quantitatively evaluate periodic and maximum energy loads for broiler-standard design models by the Ministry of Agriculture, Foodand Rural Affairs (2016). Building energy simulation method was used to compute heating and cooling loads of the designed broiler houses accordingto regional locations and insulation characteristics of wall and roof. It considered sensible and latent heat generation from broilers, dynamic operationof ventilation system according to environment variations. It was found that variation of periodic heating loads was relatively higher than that of periodiccooling loads according to thickness changes of wall and roof. Assuming that broiler was raised at every even-month, periodic heating and cooling loadswere 6 and 18% lower, respectively than odd-month raising condition. When recommendation rules of insulation characteristics (wall and roof thickness)by the Ministry of Land, Infrastructure and Transport was adopted, periodic heating load of Jeju-si was 20.3% higher than national average values. Based on the BES computed periodic and maximum energy loads under the designed experimental condition, these results can contribute toreestablishing standard design of broiler houses, especially for insulation characteristics, and designing management strategies for efficient energy uses.
참고문헌 (10)
- Alvarez-Sánchez, E., "Evaluation of thermal behavior for an asymmetric greenhouse by means of dynamic simulations", DYNA, 81(188), pp.152~159 (2014)
- Ha, T., "Computation and field experiment validation of greenhouse energy load using building energy simulation model", International Journal of Agricultural and Biological Engineering, 8(6), pp.116~127 (2015)
- 하태환, "BES 기법을 이용한 육계사 내부 고온 스트레스 평가를 위한 THI 지수 모의", 한국농공학회논문집, 60(2), pp.75~84 (2018), 한국농공학회[DOI]
- 홍세운, "BES 기법을 이용한 자연환기식 육계사의 난방에너지 분석", 한국농공학회논문집, 50(1), pp.39~47 (2008), 한국농공학회
- Jang, J. C., "Peak cooling and heating load and energy simulation study for a special greenhouse facility", Journal of the Korean Solar Energy Society, 29(1), pp.72~76 (2009)
- 권경석, "BES 수치모델을 이용한 사육 밀도별 가금류 고온 스트레스 평가", 한국산학기술학회논문지, 20(1), pp.456~463 (2019), 한국산학기술학회[DOI]
- Ministry of Agriculture, Food and Rural Affairs(MAFRA), "Released copy", ~ (2017)