BES 프로그램을 이용한 국내 대표적 대형온실의 에너지 부하 예측
Prediction of Greenhouse Energy Loads using Building Energy Simulation (BES)
2
조회
0
다운로드
12
인용
0
참고문헌
키워드
초록
Reliable estimation of energy load inside the greenhouse and the selection of cooling and heating facilities are very important preceding factors to save energy as well as initial and maintenance costs of operating a greenhouse. Recently, building energy simulation (BES) technique to simulate a model similar to the actual conditions through a variety of dynamic simulation methods,and predict and analyze the flow of energy is being actively introduced and developed. As a fundamental research to apply the BES technique which is mainly used for analysis of general buildings, to greenhouse, this research designed four types of naturally-ventilated greenhouses using one of commercial programs, TRNSYS, and then compared and analyzed their energy load properties, by applying meteorological data collected from six regions in Korea. When comparing the greenhouse load of each region depending on latitude and topographical characteristics through simulation, Chuncheon had nearly 9∼49 % higher heating load per year than other regions,but its annual cooling load was the reverse to it. Except for Jeju, 1-2W type greenhouses in five regions showed about 17 % higher heating load than a widespan type greenhouse, and 1-2W type greenhouses in Chuncheon, Suwon, Cheongju, Daegu, Cheonju and Jeju had 23 %, 20 %, 17 %, 16 %, 18 % and 20 % higher cooling load respectively than a wide span-type one. Glasshouse and vinyl greenhouse showed 8∼11 % and 10∼12 % differences respectively in heating load, while 2∼10 % and 7∼10 % differences in cooling load respectively.
Abstract
Reliable estimation of energy load inside the greenhouse and the selection of cooling and heating facilities are very important preceding factors to save energy as well as initial and maintenance costs of operating a greenhouse. Recently, building energy simulation (BES) technique to simulate a model similar to the actual conditions through a variety of dynamic simulation methods,and predict and analyze the flow of energy is being actively introduced and developed. As a fundamental research to apply the BES technique which is mainly used for analysis of general buildings, to greenhouse, this research designed four types of naturally-ventilated greenhouses using one of commercial programs, TRNSYS, and then compared and analyzed their energy load properties, by applying meteorological data collected from six regions in Korea. When comparing the greenhouse load of each region depending on latitude and topographical characteristics through simulation, Chuncheon had nearly 9∼49 % higher heating load per year than other regions,but its annual cooling load was the reverse to it. Except for Jeju, 1-2W type greenhouses in five regions showed about 17 % higher heating load than a widespan type greenhouse, and 1-2W type greenhouses in Chuncheon, Suwon, Cheongju, Daegu, Cheonju and Jeju had 23 %, 20 %, 17 %, 16 %, 18 % and 20 % higher cooling load respectively than a wide span-type one. Glasshouse and vinyl greenhouse showed 8∼11 % and 10∼12 % differences respectively in heating load, while 2∼10 % and 7∼10 % differences in cooling load respectively.
참고문헌 (9)
- Hong, S. W., "Analytical comparison on ventilation efficiencies of naturally-ventilated multi-span greenhouse and development of crop model using CFD technology", 석사, pp.2008
- 홍세운, "BES 기법을 이용한 자연환기식 육계사의 난방에너지 분석", 한국농공학회논문집, 50(1), pp.39~47 (2008), 한국농공학회
- 유호선, "시험공간에 대한 냉방부하 실증실험 및 계산", 설비공학 논문집, 15(8), pp.3~651 (2003), 대한설비공학회
- Jang, J. C., "Peak cooling and heating load and energy simulation study for a special greenhouse facility", Journal of the Korean Solar Energy Society, 29(1), pp.72~76 (2009)
- 김동혁, "강제환기가 적용된 시험공간에서 냉난방부하의 시뮬레이션 및 실증실험", 설비공학 논문집, 18(12), pp.947~954 (2006), 대한설비공학회
- Korea Energy Economics Institute (KEEI), "Yearbook of energy statistics", ~ (2010)
- Lee, J. H., "An analysis of comparison between the evaluation tool for building energy efficiency rating system and detailed analysis programs", SAREK 2009 Summer Annual Conference, 2009(6), pp.3~8 (2009)
- Rural Development Administration(RDA), "Guide book of energy cost down protected horticulture for overcome of high oil price", National Institute of Agricultural Engineering of RDA, ~ (2006)
- Solar Energy Laboratory (SEL), "TRNSYS 16 reference manual" (2007), University of Wisconsin