Most of the broiler houses in Korea have experienced problems on controlling the environmental conditions such as suitability, stability and uniformity of rearing condition inside the broiler house. It is very critical which if not properly controlled, would cause serious stress on the chickens. It is therefore urgent to develop optimum designs of naturally ventilated broiler house which is appropriate to the four seasons of Korea. Field experiment for this matter is very difficult to conduct due to the unpredictable and uncontrollable weather condition. In this study, the heating load of a naturally ventilated broiler house was calculated using TRANSYS 15 BES program while internal climate and thermal condition were computed using Fluent 6.2. The computed resulted of the conventional ventilation system (A) and upgraded ventilation system (B) (Seo et al, 2007) were compared with each other for cold season. The results of the Building Energy Simulation (BES) indicated that the system B, the upgraded ventilation system made 8% lower total heating load and 47% lower at only the broiler zone compared to the conventional broiler house. Considering the entire broiler house, the existence of middle ceiling made the heating energy 11% lower required than without middle ceiling. Accordingly, the system B with middle ceiling was found to save heating energy by 20% in average. This study showed that the BES program can be a very powerful to effectively compute the energy loads of agricultural building while the energy load is very close related to ventilation efficiency.
Abstract
Most of the broiler houses in Korea have experienced problems on controlling the environmental conditions such as suitability, stability and uniformity of rearing condition inside the broiler house. It is very critical which if not properly controlled, would cause serious stress on the chickens. It is therefore urgent to develop optimum designs of naturally ventilated broiler house which is appropriate to the four seasons of Korea. Field experiment for this matter is very difficult to conduct due to the unpredictable and uncontrollable weather condition. In this study, the heating load of a naturally ventilated broiler house was calculated using TRANSYS 15 BES program while internal climate and thermal condition were computed using Fluent 6.2. The computed resulted of the conventional ventilation system (A) and upgraded ventilation system (B) (Seo et al, 2007) were compared with each other for cold season. The results of the Building Energy Simulation (BES) indicated that the system B, the upgraded ventilation system made 8% lower total heating load and 47% lower at only the broiler zone compared to the conventional broiler house. Considering the entire broiler house, the existence of middle ceiling made the heating energy 11% lower required than without middle ceiling. Accordingly, the system B with middle ceiling was found to save heating energy by 20% in average. This study showed that the BES program can be a very powerful to effectively compute the energy loads of agricultural building while the energy load is very close related to ventilation efficiency.
참고문헌 (13)
- 강용태, "Trnsys 를 이용한 동적 열부하 계산 및 태양열 냉방 시스템의 최적화", 석사, pp.1989
- 최원기, "TRNSYS를 이용한 건물 에너지 해석", pp.527~548 (2004), 도서출판 건기원
- Cho. S, "Predictive control of intermittently operated radiant floor heating systems", Energy Conversion and Management, 44, pp.1333~1342 (2002)
- Hong, T., "Building simulation : an overview of developments and information sources", Building and Environment, 35, pp.347~361 (2000)
- Kim, Y, "The newest air conditioning equipment", pp.462~463 (1999), Bomundang
- Lee, I., "Study on ventilation efficiency of a naturally ventilated broiler house - (I) Summer season", Journal of Livestock Housing and Environment, 9(1), pp.9~18 (2003)
- Lee, I., "Study on ventilation efficiency of a mechanically ventilated broiler house - (I) Summer season", Journal of Livestock Housing and Environment, 9(2), pp.103~112 (2003)
- Lee. I, , Evaluation of CFD accuracy for the ventilation study of a naturally ventilated broiler house, 41(1), pp.53~64 (2007)
- "SEL (Solar Energy Laboratory), 1994, TRNSYS reference manual, University of Wisconsin at Madison", ~ (1994)
- Seo, I., "Improvement of ventilation efficiency of a naturally ventilated broiler house in cold season", Biosystems Engineering (2007)
- "Statistical survey of livestock industry, 2006, National Agricultural Product Quality Management Service, Korea", ~ (2006)
- 유호선, "한국형 아파트의 냉난방 에너지에 미치는 제 인자의 영향", 설비공학 논문집, 14(11), pp.13~980 (2002), 대한설비공학회
- Xin H., "Heat and moisture production of broiler chickens in commercial housing, Livestock Environment, VI" (2002)