본문 바로가기
KERD
논문KCI 등재

Comparison of the QIAGEN artus HBV QS-RGQ Assay With the Roche COBAS AmpliPrep/COBAS TaqMan HBV Assay for Quantifying Viral DNA in Sera of Chronic Hepatitis B Patients

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류병리학

초록

Background: Hepatitis B virus DNA quantification is essential for managing chronic hepatitis B (CHB). We compared the performance of artus HBV QS-RGQ (QIAGEN GmbH, Germany) and CAP/CTM v2.0 HBV assays (Roche Molecular Diagnostics, USA) in CHB patients. Methods: A comparative evaluation between two assays was performed with 508 clinical serum samples. Precision, linearity, and the limit of detection (LOD) of QS-RGQ assay was evaluated by using the WHO standard 97/750 and clinical samples. Results: Detection rates and viral loads as determined QS-RGQ assay were significantly lower than those from the CAP/CTM v2.0 assay (52.8% vs 60.6%; 3.55±1.77 IU/mL vs 4.18±1.89 IU/mL, P<0.0001). The kappa coefficient between qualitative results was 0.79 (95% confidence interval, 0.74 to 0.85). Bland-Altman plot found a mean difference of (QS-RGQ - CAP/CTM v2.0)=–0.63 log10 IU/mL (95% limit of agreement, –1.48 to 0.22). Repeatability and total imprecision (% CV) of the QS-RGQ assay were 1.0% and 1.1% at 2,000 IU/mL, and 0.7% and 1.4% at 20,000 IU/mL, respectively. Linearity of this assay ranged from 31.6 to 1.0±107 IU/mL, and the LOD was 2.95 IU/mL. Conclusions: The artus HBV QS-RGQ assay showed good performance but significantly decreased detection rate and viral load compared with CAP/CTM v2.0 assays. This assay recommends using plasma; however, we used stored serum because of the retrospective study design. Usually HBV DNA quantification is performed in plasma or serum, but sample type and clinical relevance of quantitative values should be considered when determining the clinical application of this reagent.

Abstract

Background: Hepatitis B virus DNA quantification is essential for managing chronic hepatitis B (CHB). We compared the performance of artus HBV QS-RGQ (QIAGEN GmbH, Germany) and CAP/CTM v2.0 HBV assays (Roche Molecular Diagnostics, USA) in CHB patients. Methods: A comparative evaluation between two assays was performed with 508 clinical serum samples. Precision, linearity, and the limit of detection (LOD) of QS-RGQ assay was evaluated by using the WHO standard 97/750 and clinical samples. Results: Detection rates and viral loads as determined QS-RGQ assay were significantly lower than those from the CAP/CTM v2.0 assay (52.8% vs 60.6%; 3.55±1.77 IU/mL vs 4.18±1.89 IU/mL, P<0.0001). The kappa coefficient between qualitative results was 0.79 (95% confidence interval, 0.74 to 0.85). Bland-Altman plot found a mean difference of (QS-RGQ - CAP/CTM v2.0)=–0.63 log10 IU/mL (95% limit of agreement, –1.48 to 0.22). Repeatability and total imprecision (% CV) of the QS-RGQ assay were 1.0% and 1.1% at 2,000 IU/mL, and 0.7% and 1.4% at 20,000 IU/mL, respectively. Linearity of this assay ranged from 31.6 to 1.0±107 IU/mL, and the LOD was 2.95 IU/mL. Conclusions: The artus HBV QS-RGQ assay showed good performance but significantly decreased detection rate and viral load compared with CAP/CTM v2.0 assays. This assay recommends using plasma; however, we used stored serum because of the retrospective study design. Usually HBV DNA quantification is performed in plasma or serum, but sample type and clinical relevance of quantitative values should be considered when determining the clinical application of this reagent.

참고문헌 (21)

  1. "Hepatitis B"[URL]
  2. Oakes K, "Hepatitis B : prevalence and pathophysiology", Nurs Times, 110, pp.12~16 (2014)
  3. Lok AS, "Chronic hepatitis B: update 2009", Hepatology, 50, pp.661~662 (2009)
  4. Martin P, "A treatment algorithm for the management of chronic hepatitis B virus infection in the United States: 2015 Update", Clin Gastroenterol Hepatol, 13, pp.2071~2087 (2015)
  5. González R, "Efficacy of hepatitis B virus (HBV) DNA screening and characterization of acute and occult HBV infections among blood donors from Madrid, Spain", Transfusion, 50, pp.221~230 (2010)
  6. Jiang JN, "Residual amount of HBV DNA in serum is related to relapse in chronic hepatitis B patients after cessation of nucleos(t)ide analogs", J Clin Gastroenterol, 49, pp.323~328 (2015)
  7. Stelzl E, "Rapid quantification of hepatitis B virus DNA by automated sample preparation and real-time PCR", J Clin Microbiol, 42, pp.2445~2449 (2004)
  8. Poljak M, "Recent developments in serologic and molecular diagnosis of hepatitis B and C", Acta medica Croatica, 67, pp.281~290 (2013)
  9. Ismail AM, "Performance characteristics and comparison of Abbott and artus real-time systems for hepatitis B virus DNA quantification", J Clin Microbiol, 49, pp.3215~3221 (2011)
  10. Yeh ML, "Comparison of the Abbott RealTime HBV assay with the Roche Cobas AmpliPrep", Cobas TaqMan HBV assay for HBV DNA detection and quantification, 2014, pp.60, 206~214
  11. Brichler S, "P0543: Comparative evaluation of the artus HBV QS-RGQ assay and the roche cobas mpliprep", cobas taqman V.2 HBV test for the quantification of HBV DNA in plasma, 2015, pp.62, S518~S519
  12. Fielder H, "Quantitative detection of hepatitis B virus (HBV) DNA with the novel artus® HBV QS-RGQ Kit version 2", J Clin Virol, 70, pp.S85~ (2015)
  13. Allice T, "COBAS AmpliPrep-COBAS TaqMan hepatitis B virus (HBV) test: a novel automated real-time PCR assay for quantification of HBV DNA in plasma", J Clin Microbiol, 45, pp.828~834 (2007)
  14. Chevaliez S, "Performance of version 2.0 of the Cobas AmpliPrep", Cobas TaqMan real-time PCR assay for hepatitis B virus DNA quantification, 2010, pp.48, 3641~3647
  15. Caliendo AM, "Multilaboratory evaluation of real-time PCR tests for hepatitis B virus DNA quantification", J Clin Microbiol, 49, pp.2854~2858 (2011)
  16. Lok AS, "Natural history and control of perinatally acquired hepatitis B virus infection", Dig Dis, 10, pp.46~52 (1992)
  17. Funk ML, "World-wide epidemiology of HBeAg-negative chronic hepatitis B and associated precore and core promoter variants", J Viral Hepat, 9, pp.52~61 (2002)
  18. Lindh M, "Lamivudine resistance of hepatitis B virus masked by coemergence of mutations in probe region of the COBAS AMPLICOR assay", J Clin Microbiol, 44, pp.2587~2589 (2006)
  19. Yeh ML, "Abbott RealTime HBV assay is more sensitive in detection of low viral load and little impacted by drug resistant mutation in chronic hepatitis B patients under nucleot(s)ide analogues therapy", PLoS One, 9, pp.e101790~ (2014)
  20. Alestig E, "Phylogenetic origin of hepatitis B virus strains with precore C-1858 variant", J Clin Microbiol, 39, pp.3200~3203 (2001)
  21. Alexopoulou A, "HBeAg negative variants and their role in the natural history of chronic hepatitis B virus infection", World J Gastroenterol, 20, pp.7644~7652 (2014)

관련 논문AI추천

Performance Evaluation of the Beckman Coulter DxN VERIS Hepatitis B Virus (HBV) Assay in Comparison With the Abbott RealTime HBV Assay김용구, 류지형, 박준홍, 박혜선, 신상현, 오은지, 이건동, 이혜영, 조한울, 최승준대한진단검사의학회 · Annals of Laboratory Medicine2019 · 제39권 제1호Elecsys Hepatitis B Surface Antigen Quantitative Assay: Performance Evaluation and Correlation with Hepatitis B Virus DNA during 96 Weeks of Follow-up in Chronic Hepatitis B Patients허정, 김신영, 김형회, 손한철, 이선민, 이은엽, 이현지, 장철훈대한진단검사의학회 · Annals of Laboratory Medicine2012 · 제32권 제6호Performance Evaluation of the Roche Cobas 5800 HBV and HCV Tests: Comparison of the 200 and 500 μL ProtocolsCho Eun-Jung, Jeong Seri, Kim Han-Sung, Kim Hyun Soo, Kim Jae-Seok, Lee Su-Kyung, Lee Young Kyung, Song Wonkeun대한진단검사의학회 · Annals of Laboratory Medicine2024 · 제44권 제3호Result Patterns and Characteristics of HBeAg and HBV DNA in Patients with Chronic Hepatitis B김재한, 최은진, 한미순대한진단검사의학회 · Laboratory Medicine Online2019 · 제9권 제4호B형 간염 바이러스 실시간 정량법(RealArt HBV LC PCR)의 평가김학철, 문형배, 박도심, 이기은, 이영진, 이혜수, 조은영, 조지현, 최창수대한임상미생물학회 · Annals of Clinical Microbiology2007 · 제10권 제1호VERSANT Hepatitis B Virus DNA 3.0 검사와 Digene Hybrid Capture II Hepatitis B Virus DNA 검사의 비교 및 B형 간염 임상상과의 관련성노은연, 송은영, 윤여민, 이경아, 이규만, 이창훈, 최영숙, 허미나대한진단검사의학회 · Annals of Laboratory Medicine2007 · 제27권 제6호

이 간행물의 다른 논문 (17건)