본문 바로가기
KERD
논문KCI 등재

Performance Evaluation of the Roche Cobas 5800 HBV and HCV Tests: Comparison of the 200 and 500 μL Protocols

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류병리학

초록

Background: Clinical management of patients infected with hepatitis B virus (HBV) or hepatitis C virus (HCV) relies on the viral load (VL). The Cobas 5800 system (Roche Diagnostics) can determine VLs in 200 and 500 μL samples, but the performance of each protocol has not been compared. We evaluated the performance of both protocols for the HBV and HCV tests. Methods: Precision and linearity were verified using commercial panels. Probit analyses were used to determine limits of detection (LoDs). The results obtained with 336 samples were compared using the 200 and 500 μL protocols. Data from 6,737 retrospective HBV and 768 HCV samples were compared to estimate the effects of the different LoDs on the diagnostic results of the protocols. Correlations between protocols were tested with Spearman’s rank correlation coefficients (rho). Results: The precision and linearity of both protocols were verified. The LoDs for the 200 and 500 μL protocols were 6.5 and 2.7 IU/mL for HBV and 29.7 and 8.2 IU/mL for HCV, respectively. The agreement between the protocols ranged from 0.8 to 1.0. The results obtained with the HBV and HCV tests showed a strong correlation (rho=0.994). Only 0.4% of HBV and 0.4% of HCV test results were affected by the LoDs of the 200 μL protocol. Conclusions: The Cobas 5800 200 and 500 μL protocols for the HBV DNA and HCV RNA tests demonstrated excellent performance. These findings establish the 200 μL protocol as a new option for low-volume samples, especially for pediatric and difficult-to-bleed patients.

Abstract

Background: Clinical management of patients infected with hepatitis B virus (HBV) or hepatitis C virus (HCV) relies on the viral load (VL). The Cobas 5800 system (Roche Diagnostics) can determine VLs in 200 and 500 μL samples, but the performance of each protocol has not been compared. We evaluated the performance of both protocols for the HBV and HCV tests. Methods: Precision and linearity were verified using commercial panels. Probit analyses were used to determine limits of detection (LoDs). The results obtained with 336 samples were compared using the 200 and 500 μL protocols. Data from 6,737 retrospective HBV and 768 HCV samples were compared to estimate the effects of the different LoDs on the diagnostic results of the protocols. Correlations between protocols were tested with Spearman’s rank correlation coefficients (rho). Results: The precision and linearity of both protocols were verified. The LoDs for the 200 and 500 μL protocols were 6.5 and 2.7 IU/mL for HBV and 29.7 and 8.2 IU/mL for HCV, respectively. The agreement between the protocols ranged from 0.8 to 1.0. The results obtained with the HBV and HCV tests showed a strong correlation (rho=0.994). Only 0.4% of HBV and 0.4% of HCV test results were affected by the LoDs of the 200 μL protocol. Conclusions: The Cobas 5800 200 and 500 μL protocols for the HBV DNA and HCV RNA tests demonstrated excellent performance. These findings establish the 200 μL protocol as a new option for low-volume samples, especially for pediatric and difficult-to-bleed patients.

참고문헌 (25)

  1. "Guidelines on hepatitis B and C testing" (2017)[URL]
  2. "HCV guidance: recommendations for testing, managing, and treating hepatitis C" (2021)[URL]
  3. European Association for the Study of the Liver, "EASL 2017 Clinical Practice Guidelines on the management of hepatitis B virus infection", J Hepatol, 67, pp.370~398 (2017)
  4. European Association for the Study of the Liver, "EASL recommendations on treatment of hepatitis C 2018", J Hepatol, 69, pp.461~511 (2018)
  5. Terrault NA, "Update on prevention, diagnosis, and treatment of chronic hepatitis B: AASLD 2018 hepatitis B guidance", Hepatology, 67, pp.1560~1599 (2018)
  6. Hur M, "Comparison of non-invasive clinical algorithms for liver fibrosis in patients with chronic hepatitis B to reduce the need for liver biopsy : application of enhanced liver fibrosis and Mac-2 binding protein glycosylation isomer", Ann Lab Med, 42, pp.249~257 (2022)
  7. Andersson KL, "Monitoring during and after antiviral therapy for hepatitis B", Hepatology, 49(S5), pp.S166~S173 (2009)
  8. Braun P, "A European multicientre study on the comparison of HBV viral loads between VERIS HBV assay and Roche COBAS® TAQMAN® HBV test, Abbott RealTime HBV assay, Siemens VERSANT HBV assay, and Qiagen Artus HBV RG kit", J Clin Virol, 95, pp.76~83 (2017)
  9. Park Y, "Performance evaluation of the Aptima assays in comparison with the cobas 6800 Assays for the detection of HIV-1, HBV, and HCV in clinical samples", Ann Lab Med, 42, pp.447~456 (2022)
  10. Tschäpe J, "Multisite performance evaluation of the Cobas 5800 System and comparison to the Cobas 6800", 8800 systems for quantitative measurement of HBV, HCV, and HIV-1 viral load, 2022, pp.10, e0312522~
  11. Tan NK, "Verification of the Roche Cobas® 6800 PCR 200 μl and 500 μl protocols for the quantification of HIV-1 RNA, HBV DNA and HCV RNA and evaluation with COBAS® Ampliprep", COBAS® TaqMan® assays, 2018, pp.67, 1711~1717
  12. McHugh ML, "Interrater reliability : the kappa statistic", Biochem Med(Zagreb), 22, pp.276~282 (2012)
  13. Schober P, "Correlation coefficients : appropriate use and interpretation", Anesth Analg, 126, pp.1763~1768 (2018)
  14. European Association for the Study of the Liver, "EASL clinical practice guidelines : management of chronic hepatitis B virus infection", J Hepatol, 57, pp.167~185 (2012)
  15. Terrault NA, "AASLD guidelines for treatment of chronic hepatitis B", Hepatology, 63, pp.261~283 (2016)
  16. Sidharthan S, "Utility of hepatitis C viral load monitoring on direct-acting antiviral therapy", Clin Infect Dis, 60, pp.1743~1751 (2015)
  17. Wirden M, "Multicenter comparison of the new Cobas 6800 system with Cobas Ampliprep", Cobas TaqMan and Abbott RealTime for the quantification of HIV, HBV and HCV viral load, 2017, pp.96, 49~53
  18. Baylis SA, "Harmonization of nucleic acid testing for Zika virus : development of the 1st World Health Organization International Standard", Transfusion, 57, pp.748~761 (2017)
  19. Baylis SA, "Standardization of nucleic acid tests : the approach of the World Health Organization", J Clin Microbiol, 57, pp.e01056-18~ (2019)
  20. Scholtès C, "Performance of the Cobas® HBV RNA automated investigational assay for the detection and quantification of circulating HBV RNA in chronic HBV patients", J Clin Virol, 150-151, pp.105150~ (2022)
  21. Caliendo AM, "Multilaboratory evaluation of real-time PCR tests for hepatitis B virus DNA quantification", J Clin Microbiol, 49, pp.2854~2858 (2011)
  22. Han MS, "Comparison of the Qiagen Artus HBV QS-RGQ assay with the Roche COBAS AmpliPrep", COBAS TaqMan HBV assay for quantifying viral DNA in sera of chronic hepatitis B patients, 2017, pp.37, 248~253
  23. Ismail AM, "Performance characteristics and comparison of Abbott and Artus real-time systems for hepatitis B virus DNA quantification", J Clin Microbiol, 49, pp.3215~3221 (2011)
  24. Yeh ML, "Abbott RealTime HBV assay is more sensitive in detection of low viral load and little impacted by drug resistant mutation in chronic hepatitis B patients under nucleot(s)ide analogues therapy", PLoS One, 9, pp.e101790~ (2014)
  25. Vermehren J, "Development of a second version of the Cobas AmpliPrep", Cobas TaqMan hepatitis C virus quantitative test with improved genotype inclusivity, 2011, pp.49, 3309~3315

관련 논문AI추천

Performance Evaluation of the Aptima Assays in Comparison with the cobas 6800 Assays for the Detection of HIV-1, HBV, and HCV in Clinical SamplesKim Sinyoung, Park Younhee, Roh Juhye대한진단검사의학회 · Annals of Laboratory Medicine2022 · 제42권 제4호Performance Evaluation of Aptima HBV and HCV Quant Assays in the Panther System김보연, 김윤정, 이경아, 최유정대한진단검사의학회 · Laboratory Medicine Online2021 · 제11권 제3호Comparison of the QIAGEN artus HBV QS-RGQ Assay With the Roche COBAS AmpliPrep/COBAS TaqMan HBV Assay for Quantifying Viral DNA in Sera of Chronic Hepatitis B Patients김현숙, 나현진, 박용정, 한미순대한진단검사의학회 · Annals of Laboratory Medicine2017 · 제37권 제3호Performance Evaluation of the Beckman Coulter DxN VERIS Hepatitis B Virus (HBV) Assay in Comparison With the Abbott RealTime HBV Assay김용구, 류지형, 박준홍, 박혜선, 신상현, 오은지, 이건동, 이혜영, 조한울, 최승준대한진단검사의학회 · Annals of Laboratory Medicine2019 · 제39권 제1호Elecsys Hepatitis B Surface Antigen Quantitative Assay: Performance Evaluation and Correlation with Hepatitis B Virus DNA during 96 Weeks of Follow-up in Chronic Hepatitis B Patients허정, 김신영, 김형회, 손한철, 이선민, 이은엽, 이현지, 장철훈대한진단검사의학회 · Annals of Laboratory Medicine2012 · 제32권 제6호Evaluation of the VIDAS Anti-HCV Assay for Detection of Hepatitis C Virus Infection강희정, 고대현, 김현수, 차영주, 현정원, 황동희대한진단검사의학회 · Annals of Laboratory Medicine2016 · 제36권 제6호

이 간행물의 다른 논문 (13건)