Long-Term Efficacy and Rotational Stability of AcrySof Toric Intraocular Lens Implantation in Cataract Surgery
2
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
Purpose: To evaluate the long-term efficacy and rotational stability of the AcrySof toric intraocular lens (IOL) in correcting preoperative astigmatism in cataract patients. Methods: This prospective observational study included 30 eyes from 24 consecutive patients who underwent implantation of an AcrySof toric IOL with micro-coaxial cataract surgery between May 2008 and September 2008. Outcomes of visual acuity, refractive and keratometric astigmatism, and IOL rotation after 1 day, 1 month, 3 months, and long-term (mean, 13.3±5.0 months) follow-up were evaluated. Results: At final follow-up, 73.3% of eyes showed an uncorrected visual acuity of 20/25 or better. The postoperative keratometric value was not different from the preoperative value; mean refractive astigmatism was reduced to -0.28±0.38 diopter (D) from -1.28±0.48 D. The mean rotation of the toric IOL was 3.45±3.39 degrees at final follow-up. One eye (3.3%) exhibited IOL rotation of 10.3 degrees, the remaining eyes (96.7%) had IOL rotation of less than 10 degrees. Conclusions: Early postoperative and long-term follow-up showed that implantation of the AcrySof toric IOL is an effective, safe, and predictable method for managing corneal astigmatism in cataract patients.
Abstract
Purpose: To evaluate the long-term efficacy and rotational stability of the AcrySof toric intraocular lens (IOL) in correcting preoperative astigmatism in cataract patients. Methods: This prospective observational study included 30 eyes from 24 consecutive patients who underwent implantation of an AcrySof toric IOL with micro-coaxial cataract surgery between May 2008 and September 2008. Outcomes of visual acuity, refractive and keratometric astigmatism, and IOL rotation after 1 day, 1 month, 3 months, and long-term (mean, 13.3±5.0 months) follow-up were evaluated. Results: At final follow-up, 73.3% of eyes showed an uncorrected visual acuity of 20/25 or better. The postoperative keratometric value was not different from the preoperative value; mean refractive astigmatism was reduced to -0.28±0.38 diopter (D) from -1.28±0.48 D. The mean rotation of the toric IOL was 3.45±3.39 degrees at final follow-up. One eye (3.3%) exhibited IOL rotation of 10.3 degrees, the remaining eyes (96.7%) had IOL rotation of less than 10 degrees. Conclusions: Early postoperative and long-term follow-up showed that implantation of the AcrySof toric IOL is an effective, safe, and predictable method for managing corneal astigmatism in cataract patients.
참고문헌 (22)
- Hoffer KJ, "Biometry of 7,500 cataractous eyes", Am J Ophthalmol, 90, pp.360~368 (1980)
- Shimizu K, "Toric intraocular lenses: correcting astigmatism while controlling axis shift", J Cataract Refract Surg, 20, pp.523~526 (1994)
- Grabow HB, "Early results of 500 cases of no-stitch cataract surgery", J Cataract Refract Surg, 17(Suppl), pp.726~730 (1991)
- Werblin TP, "Do three-piece PMMA IOLs rotate after implantation in the capsular bag?", J Refract Surg, 11, pp.468~471 (1995)
- Ruhswurm I, "Astigmatism correction with a foldable toric intraocular lens in cataract patients", J Cataract Refract Surg, 26, pp.1022~1027 (2000)
- Sun XY, "Toric intraocular lenses for correcting astigmatism in 130 eyes", Ophthalmology, 107, pp.1776~1781 (2000)
- Leyland M, "Prospective evaluation of a plate haptic toric intraocular lens", Eye (Lond), 15, pp.202~205 (2001)
- Till JS, "Toric intraocular lens implantation: 100 consecutive cases", J Cataract Refract Surg, 28, pp.295~301 (2002)
- Chang DF, "Early rotational stability of the longer Staar toric intraocular lens: fifty consecutive cases", J Cataract Refract Surg, 29, pp.935~940 (2003)
- De Silva DJ, "Evaluation of a toric intraocular lens with a Z-haptic", J Cataract Refract Surg, 32, pp.1492~1498 (2006)
- Horn JD, "Status of toric intraocular lenses", Curr Opin Ophthalmol, 18, pp.58~61 (2007)
- Ohmi S, "Decentration associated with asymmetric capsular shrinkage and intraocular lens size", J Cataract Refract Surg, 19, pp.640~643 (1993)
- Strenn K, "Capsular bag shrinkage after implantation of an open-loop silicone lens and a poly (methyl methacrylate) capsule tension ring", J Cataract Refract Surg, 23, pp.1543~1547 (1997)
- Sanders DR, "The toric IOL. In:Sutureless cataract surgery: an evolution toward minimally invasive technique", pp.183~197 (1992), Slack, Inc
- Husain SE, "Computerized videokeratography and keratometry in determining intraocular lens calculations", J Cataract Refract Surg, 22, pp.362~366 (1996)
- Grabow HB, "Intraocular correction of refractive errors. In:Refractive keratectomy for cataract surgery and the correction of astigmatism", pp.79~115 (1994), Slack, Inc
- Novis C, "Astigmatism and toric intraocular lenses", Curr Opin Ophthalmol, 11, pp.47~50 (2000)
- Patel CK, "Postoperative intraocular lens rotation: a randomized comparison of plate and loop haptic implants", Ophthalmology, 106, pp.2190~2195 (1999)
- Weinand F, "Rotational stability of a single-piece hydrophobic acrylic intraocular lens: new method for high-precision rotation control", J Cataract Refract Surg, 33, pp.800~803 (2007)
- Zuberbuhler B, "Rotational stability of the AcrySof SA60TT toric intraocular lenses: a cohort study", BMC Ophthalmol, 8, pp.8~ (2008)
- Mendicute J, "Foldable toric intraocular lens for astigmatism correction in cataract patients", J Cataract Refract Surg, 34, pp.601~607 (2008)
- 나정화, "난시교정인공수정체 삽입 후 임상 결과", 대한안과학회지, 50(6), pp.831~838 (2009), 대한안과학회
