초록

The identification of explosive residues on specimens obtained from an explosion event is a crucial factor for assessing the cause of the explosion. In order to detect the components of explosives, the explosive residues deposited on surfaces are commonly extracted using swabbing materials pre-wetted with an organic solvent. The residues are then analyzed with analytical instruments such as LC/MS and CE/MS. Most conventionally used swabbing media such as cotton swabs or cotton tip swabs seem unsuitable for extracting explosive residues from the surface of a large area of clothes because the swabbing materials tend to be damaged easily, and because only a relatively small amount of explosives is collected. To overcome these problems, we have introduced a novel wiper (215 × 210 mm, single layer, Yuhan-Kimberly, Republic of Korea) as a swabbing material to recover representative organic explosives, namely, TNT, RDX, tetryl, HMX, PETN, and NG, from a large area of clothes. Different sides of the wiper, which was folded in half five times, was used to swab the surface of a clothing. We compared this novel wiper with a cotton swab and a cotton tip swab in terms of the recovery efficiency for the aforementioned organic explosives by pre-wetting with methanol, acetone, and acetonitrile, respectively. We identified that this novel wiper collected a significantly higher amount of organic explosive residues than a cotton swab or a cotton tip swab when using methanol as an extracting solvent.

Abstract

The identification of explosive residues on specimens obtained from an explosion event is a crucial factor for assessing the cause of the explosion. In order to detect the components of explosives, the explosive residues deposited on surfaces are commonly extracted using swabbing materials pre-wetted with an organic solvent. The residues are then analyzed with analytical instruments such as LC/MS and CE/MS. Most conventionally used swabbing media such as cotton swabs or cotton tip swabs seem unsuitable for extracting explosive residues from the surface of a large area of clothes because the swabbing materials tend to be damaged easily, and because only a relatively small amount of explosives is collected. To overcome these problems, we have introduced a novel wiper (215 × 210 mm, single layer, Yuhan-Kimberly, Republic of Korea) as a swabbing material to recover representative organic explosives, namely, TNT, RDX, tetryl, HMX, PETN, and NG, from a large area of clothes. Different sides of the wiper, which was folded in half five times, was used to swab the surface of a clothing. We compared this novel wiper with a cotton swab and a cotton tip swab in terms of the recovery efficiency for the aforementioned organic explosives by pre-wetting with methanol, acetone, and acetonitrile, respectively. We identified that this novel wiper collected a significantly higher amount of organic explosive residues than a cotton swab or a cotton tip swab when using methanol as an extracting solvent.

참고문헌 (23)

  1. H. E. Cullum, , J. Forensic Sci, 49(4), pp.1~7 (2004)
  2. R. Waddell, , J. Chromatogr. A, 1062, pp.125~131 (2005)
  3. J. S. Wallace, , J. Forensic Sci, 33, pp.107~116 (1993)
  4. M. E. Sigman, , Anal. Chem, 71, pp.4119~4124 (1999)
  5. A. Zeichner, , Forensic Sci. Int, 184, pp.42~46 (2009)
  6. N. Song-im, , Forensic Sci. Int, 222, pp.102~110 (2012)
  7. D. A. DeTata, , J. Forensic Sci, 58(3), pp.757~763 (2013)
  8. J. D. Twibell, , J. Forensic Sci, 27(4), pp.792~800 (1982)
  9. R. D. Voyksner, , J. Chromatogr, 354, pp.393~405 (1986)
  10. P. Kolla, , J. Forensic Sci, 36(5), pp.1342~1359 (1991)
  11. J. C. Oxley, , J. Forensic Sci, 48(2), pp.334~342 (2003)
  12. D. Perret, , Chromatographia, 68, pp.517~524 (2008)
  13. J. M. F. Douse, , J. Chromatogr, 234, pp.415~425 (1982)
  14. J. Yinon, "The analysis of explosives", pp.221~ (1981), Pergamon Press
  15. R. Kinghorn, "Analysis of trace residue of explosive materials by Time-of-Flight LC", MS, 2007
  16. M. E. Walsh, , J. Chromatogr Sci, 36, pp.406~416 (1998)
  17. X. Zhao, , J. Chromatogr. A, 977, pp.59~68 (2002)
  18. R. Tachor, , J. Chromatogr. A, 1154, pp.174~181 (2007)
  19. D. DeTata, , Forensic Sci. Intl, 233, pp.63~74 (2013)
  20. R. Tachon, , J. Chromatogr. A, 1185(1), pp.1~8 (2008)
  21. Preservation of water samples containing nitroaromatics and nitramines, "T. F. Jenkins", US Army Cold Regions Research and Engineering Laboratory, ~, pp.Special Report 93-16 (1995)
  22. N. Song-im, "Explosive residue analysis: evaluation and optimization of sampling, storage and cleanup protocols", PhD, pp.2011
  23. T. Tamiri, , J. Energ. Mater, 4, pp.215~237 (1986)

관련 논문AI추천

이 간행물의 다른 논문 (9건)