Analysis of time to failure of orthodontic mini-implants after insertion or loading
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Objectives: This study was performed to evaluate patterns of failure time after insertion, failure rate according to loading time after insertion, and the patterns of failure after loading.Materials and Methods: A total of 331 mini-implants were classifiedinto the non-failure group (NFG) and failure group (FG), which was divided into failed group before loading (FGB) and failed group after loading (FGA). Orthodontic force was applied to both the NFG and FGA. Failed mini-implants after insertion, ratio of FGA to NFG according to loading time after insertion, and failed mini-implants according to failed time after loading were analyzed.Results: Percentages of failed mini-implants after insertion were 15.79%, 36.84%, 12.28%, and 10.53% at 4, 8, 12, and 16 weeks, respectively. Mini-implant failure demonstrated a peak from 4 to 5 weeks after insertion. The failure rates according to loading time after insertion were 13.56%, 8.97%, 11.32%, and 5.00% at 4, 8, 12, and 16 weeks, respectively. Percentages of failed mini-implants after loading were 13.79%, 24.14%, 20.69%, and 6.9% at 4, 8, 12, and 16 weeks, respectively.Conclusion: Mini-implant stability is typically acquired 12 to 16 weeks after insertion, and immediate loading can cause failure of the mini-implant. Failure after loading was observed during the first 12 weeks.
Abstract
Objectives: This study was performed to evaluate patterns of failure time after insertion, failure rate according to loading time after insertion, and the patterns of failure after loading.Materials and Methods: A total of 331 mini-implants were classifiedinto the non-failure group (NFG) and failure group (FG), which was divided into failed group before loading (FGB) and failed group after loading (FGA). Orthodontic force was applied to both the NFG and FGA. Failed mini-implants after insertion, ratio of FGA to NFG according to loading time after insertion, and failed mini-implants according to failed time after loading were analyzed.Results: Percentages of failed mini-implants after insertion were 15.79%, 36.84%, 12.28%, and 10.53% at 4, 8, 12, and 16 weeks, respectively. Mini-implant failure demonstrated a peak from 4 to 5 weeks after insertion. The failure rates according to loading time after insertion were 13.56%, 8.97%, 11.32%, and 5.00% at 4, 8, 12, and 16 weeks, respectively. Percentages of failed mini-implants after loading were 13.79%, 24.14%, 20.69%, and 6.9% at 4, 8, 12, and 16 weeks, respectively.Conclusion: Mini-implant stability is typically acquired 12 to 16 weeks after insertion, and immediate loading can cause failure of the mini-implant. Failure after loading was observed during the first 12 weeks.
참고문헌 (27)
- Hee-Yeon Suh, "Use of mini-implants to avoid maxillary surgery for Class III mandibular prognathic patient: a long-term post-retention case", 대한치과교정학회지, 44(6), pp.342~349 (2014), 대한치과교정학회
- Kanomi R., "Mini-implant for orthodontic anchorage", J Clin Orthod, 31, pp.763~767 (1997)
- Hyeon-Jung Lee, "Effect of bite force on orthodontic mini-implants in the molar region: Finite element analysis", 대한치과교정학회지, 43(5), pp.218~224 (2013), 대한치과교정학회
- Herrmann I, "Evaluation of patient and implant characteristics as potential prognostic factors for oral implant failures", Int J Oral Maxillofac Implants, 20, pp.220~230 (2005)
- Lee JH, "Replacing a failed mini-implant with a miniplate to prevent interruption during orthodontic treatment", Am J Orthod Dentofacial Orthop, 139, pp.849~857 (2011)
- Wiechmann D, "Success rate of mini- and micro-implants used for orthodontic anchorage: a prospective clinical study", Clin Oral Implants Res, 18, pp.263~267 (2007)
- 김정식, "Comparison of success rates of orthodontic mini-screws by the insertion method", 대한치과교정학회지, 42(5), pp.242~248 (2012), 대한치과교정학회
- Kim SH, "Rotational resistance of surface-treated mini-implants", Angle Orthod, 79, pp.899~907 (2009)
- Grunder U., "Immediate functional loading of immediate implants in edentulous arches: two-year results", Int J Periodontics Restorative Dent, 21, pp.545~551 (2001)
- 김영균, "The seven-year cumulative survival rate of Osstem implants", 대한구강악안면외과학회지, 40(2), pp.68~75 (2014), 대한구강악안면외과학회
- Ioannidou E, "Does loading time affect implant survival? A meta-analysis of 1,266 implants", J Periodontol, 76, pp.1252~1258 (2005)
- Catharino PC, "Histologic, histomorphometric, and radiographic monitoring of bone healing around in-office-sterilized orthodontic mini-implants with or without immediate load: study in rabbit tibiae", Int J Oral Maxillofac Implants, 29, pp.321~330 (2014)
- Robling AG, "Mechanical stimulation of bone in vivo reduces osteocyte expression of Sost", sclerostin, 2008, pp.283, 5866~5875
- Klein-Nulend J, "Sensitivity of osteocytes to biomechanical stress in vitro", FASEB J, 9, pp.441~445 (1995)
- Forwood MR, "Inducible cyclo-oxygenase (COX-2) mediates the induction of bone formation by mechanical loading in vivo", J Bone Miner Res, 11, pp.1688~1693 (1996)
- Tatsumi S, "Targeted ablation of osteocytes induces osteoporosis with defective mechanotransduction", Cell Metab, 5, pp.464~475 (2007)
- 김영균, "Effect of loading time on marginal bone loss around hydroxyapatite-coated implants", 대한구강악안면외과학회지, 39(4), pp.161~167 (2013), 대한구강악안면외과학회
- Rebaudi A, "Microcomputed tomographic analysis of bone reaction at insertion of orthodontic mini-implants in sheep", Int J Oral Maxillofac Implants, 26, pp.1233~1240 (2011)
- Raghavendra S, "Early wound healing around endosseous implants: a review of the literature", Int J Oral Maxillofac Implants, 20, pp.425~431 (2005)
- Atsumi M, "Methods used to assess implant stability:current status", Int J Oral Maxillofac Implants, 22, pp.743~754 (2007)
- Abdul-Aziz Al-Sawai, "Success of immediate loading implants compared to conventionally-loaded implants: a literature review", Journal of Investigative and Clinical Dentistry (2015), Wiley-Blackwell[DOI]
- Georgios Romanos, "Effects of Early Moderate Loading on Implant Stability: A Retrospective Investigation of 634 Implants with Platform Switching and Morse-Tapered Connections", Clinical Implant Dentistry and Related Research, 18(2), pp.301~309 (2016), Wiley-Blackwell[DOI]
- Kim YK, "Prospective comparative study of tapered implants with SLA surfaces in the maxillary posterior area according to 3- and 6-month loading time", Int J Periodontics Restorative Dent, 35, pp.271~276 (2015)
- Ramazanzadeh BA, "Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study", ISRN Dent (2014)[DOI]
- Lee SJ, "Survival analysis of orthodontic mini-implants", Am J Orthod Dentofacial Orthop, 137, pp.194~199 (2010)
- Kim SH, "Removal torque values of surface-treated mini-implants after loading", Am J Orthod Dentofacial Orthop, 134, pp.36~43 (2008)
- Kim JW, "Histomorphometric and mechanical analyses of the drill-free screw as orthodontic anchorage", Am J Orthod Dentofacial Orthop, 128, pp.190~194 (2005)
