Comparison of success rates of orthodontic mini-screws by the insertion method
1
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
Objective: The aim of this study was to compare the success rates of the manual and motor-driven mini-screw insertion methods according to age, gender, length of mini-screws, and insertion sites. Methods: We retrospectively reviewed 429 orthodontic mini-screw placements in 286 patients (102 in men and 327 in women) between 2005 and 2010 at private practice. Age, gender, mini-screw length, and insertion site were cross-tabulated against the insertion methods. The Cochran-Mantel-Haenszel test was performed to compare the success rates of the 2 insertion methods. Results: The motor-driven method was used for 228 mini-screws and the manual method for the remaining 201 mini-screws. The success rates were similar in both men and women irrespective of the insertion method used. With respect to mini-screw length, no difference in success rates was found between motor and hand drivers for the 6-mm-long mini-screws (68.1% and 69.5% with the engine driver and hand driver, respectively). However, the 8-mm-long mini-screws exhibited significantly higher success rates (90.4%, p < 0.01) than did the 6-mm-long mini-screws when placed with the engine driver. The overall success rate was also significantly higher in the maxilla (p < 0.05) when the engine driver was used. Success rates were similar among all age groups regardless of the insertion method used. Conclusions: Taken together, the motor-driven insertion method can be helpful to get a higher success rate of orthodontic mini-screw placement.
Abstract
Objective: The aim of this study was to compare the success rates of the manual and motor-driven mini-screw insertion methods according to age, gender, length of mini-screws, and insertion sites. Methods: We retrospectively reviewed 429 orthodontic mini-screw placements in 286 patients (102 in men and 327 in women) between 2005 and 2010 at private practice. Age, gender, mini-screw length, and insertion site were cross-tabulated against the insertion methods. The Cochran-Mantel-Haenszel test was performed to compare the success rates of the 2 insertion methods. Results: The motor-driven method was used for 228 mini-screws and the manual method for the remaining 201 mini-screws. The success rates were similar in both men and women irrespective of the insertion method used. With respect to mini-screw length, no difference in success rates was found between motor and hand drivers for the 6-mm-long mini-screws (68.1% and 69.5% with the engine driver and hand driver, respectively). However, the 8-mm-long mini-screws exhibited significantly higher success rates (90.4%, p < 0.01) than did the 6-mm-long mini-screws when placed with the engine driver. The overall success rate was also significantly higher in the maxilla (p < 0.05) when the engine driver was used. Success rates were similar among all age groups regardless of the insertion method used. Conclusions: Taken together, the motor-driven insertion method can be helpful to get a higher success rate of orthodontic mini-screw placement.
참고문헌 (40)
- 김태우, "Clinical Application of Orthodontic Mini-implant" (2008), Myung Mun Publishing
- Nanda R, "Temporary anchorage devices in orthodontics" (2009), Mosby Elsevier
- Park HS, "Orthodontic treatment using micro-implant.2nd ed" (2006), Daehan Narae Publishing
- Baumgaertel S, "Mini-implant anchorage for the orthodontic practitioner", Am J Orthod Dentofacial Orthop, 133, pp.621~627 (2008)
- Chen CH, "The use of microimplants in orthodontic anchorage", J Oral Maxillofac Surg, 64, pp.1209~1213 (2006)
- 박효상, "교정치료 고정원으로서 Microscrew implants의 성공율에 대한 임상적 연구", 대한치과교정학회지, 33(3), pp.151~156 (2003), 대한치과교정학회
- Heidemann W, "Analysis of the osseous", metal interface of drill free screws and self-tapping screws, 2001, pp.29, 69~74
- Heidemann W, "Drill free screws: a new form of osteosynthesis screw", J Craniomaxillofac Surg, 26, pp.163~168 (1998)
- Cohen S, "Pathways of the pulp. 9th ed" (2006), Mosby Elsevier
- Eriksson RA, "Temperatures during drilling for the placement of implants using the osseointegration technique", J Oral Maxillofac Surg, 44, pp.4~7 (1986)
- Nam OH, "Effect of heat production on alvolar bone surface by ratating speedand virtual preessure of micro-implant drill", pp.2004
- Eriksson AR, "Temperature threshold levels for heat-induced bone tissue injury: a vitalmicroscopic study in the rabbit", J Prosthet Dent, 50, pp.101~107 (1983)
- Matthews LS, "Temperatures measured in human cortical bone when drilling", J Bone Joint Surg Am, 54, pp.297~308 (1972)
- Park HS, "Factors affecting the clinical success of screw implants used as orthodontic anchorage", Am J Orthod Dentofacial Orthop, 130, pp.18~25 (2006)
- Luzi C, "Guidelines for success in placement of orthodontic mini-implants", J Clin Orthod, 43, pp.39~44 (2009)
- Moon CH, "Factors associated with the success rate of orthodontic miniscrews placed in the upper and lower posterior buccal region", Angle Orthod, 78, pp.101~106 (2008)
- Miyawaki S, "Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage", Am J Orthod Dentofacial Orthop, 124, pp.373~378 (2003)
- Kuroda S, "Clinical use of miniscrew implants as orthodontic anchorage: success rates and postoperative discomfort", Am J Orthod Dentofacial Orthop, 131, pp.9~15 (2007)
- Lim HJ, "Predictors of initial stability of orthodontic miniscrew implants", Eur J Orthod, 33, pp.528~532 (2011)
- Cheng SJ, "A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage", Int J Oral Maxillofac Implants, 19, pp.100~106 (2004)
- Lim HJ, "Factors associated with initial stability of miniscrews for orthodontic treatment", Am J Orthod Dentofacial Orthop, 136, pp.236~242 (2009)
- 김영균, "미니 임플란트 시스템의 적용에 대한 다기관 후향적 임상연구", 대한구강악안면외과학회지, 36(4), pp.325~330 (2010), 대한구강악안면외과학회
- Crismani AG, "Miniscrews in orthodontic treatment: review and analysis of published clinical trials", Am J Orthod Dentofacial Orthop, 137, pp.108~113 (2010)
- Motoyoshi M, "Recommended placement torque when tightening an orthodontic mini-implant", Clin Oral Implants Res, 17, pp.109~114 (2006)
- Liou EJ, "Do miniscrews remain stationary under orthodontic forces?", Am J Orthod Dentofacial Orthop, 126, pp.42~47 (2004)
- Fritz U, "Clinical suitability of titanium microscrews for orthodontic anchorage-preliminary experiences", J Orofac Orthop, 65, pp.410~418 (2004)
- Park HS, "Group distal movement of teeth using microscrew implant anchorage", Angle Orthod, 75, pp.602~609 (2005)
- Tseng YC, "The application of mini-implants for orthodontic anchorage", Int J Oral Maxillofac Surg, 35, pp.704~707 (2006)
- Herman RJ, "Mini-implant anchorage for maxillary canine retraction: a pilot study", Am J Orthod Dentofacial Orthop, 130, pp.228~235 (2006)
- Wiechmann D, "Success rate of mini- and micro-implants used for orthodontic anchorage: a prospective clinical study", Clin Oral Implants Res, 18, pp.263~267 (2007)
- Motoyoshi M, "Application of orthodontic mini-implants in adolescents", Int J Oral Maxillofac Surg, 36, pp.695~699 (2007)
- Chen YJ, "A retrospective analysis of the failure rate of three different orthodontic skeletal anchorage systems", Clin Oral Implants Res, 18, pp.768~775 (2007)
- 임선아, "교정용 미니스크류의 형상에 따른 식립 토오크의 비교", 대한치과교정학회지, 37(2), pp.87~97 (2007), 대한치과교정학회
- Kravitz ND, "Risks and complications of orthodontic miniscrews", Am J Orthod Dentofacial Orthop, 131(4 Suppl), pp.S43~S51 (2007)
- Yared GM, "Failure of ProFile instruments used with high and low torque motors", Int Endod J, 34, pp.471~475 (2001)
- Gambarini G, "Rationale for the use of low-torque endodontic motors in root canal instrumentation", Endod Dent Traumatol, 16, pp.95~100 (2000)
- Jo WH, "Influence of the operator’s experience and drilling sites on the root contact during the drilling for micro-implants insertion", pp.2005
- Matsuoka M, "Friction heat during selfdrilling of an orthodontic miniscrew", Int J Oral Maxillofac Surg, 40, pp.191~194 (2011)
- 박진서, "Self-drilling 방식의 마이크로임플란트 식립에 의해 발생하는 피질골 스트레인의 유한요소해석", 대한치과교정학회지, 39(4), pp.203~212 (2009), 대한치과교정학회
- 유원재, "교정용 마이크로 임플란트의 경부와 인접한 치밀골의 계면조건이 골응력에 미치는 영향에 대한 유한요소해석적 연구", 대한치과기재학회지, 33(4), pp.381~393 (2006), 대한치과기재학회
