본문 바로가기
KERD
논문KCI 등재

Comparison of success rates of orthodontic mini-screws by the insertion method

1

조회

0

다운로드

4

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: The aim of this study was to compare the success rates of the manual and motor-driven mini-screw insertion methods according to age, gender, length of mini-screws, and insertion sites. Methods: We retrospectively reviewed 429 orthodontic mini-screw placements in 286 patients (102 in men and 327 in women) between 2005 and 2010 at private practice. Age, gender, mini-screw length, and insertion site were cross-tabulated against the insertion methods. The Cochran-Mantel-Haenszel test was performed to compare the success rates of the 2 insertion methods. Results: The motor-driven method was used for 228 mini-screws and the manual method for the remaining 201 mini-screws. The success rates were similar in both men and women irrespective of the insertion method used. With respect to mini-screw length, no difference in success rates was found between motor and hand drivers for the 6-mm-long mini-screws (68.1% and 69.5% with the engine driver and hand driver, respectively). However, the 8-mm-long mini-screws exhibited significantly higher success rates (90.4%, p < 0.01) than did the 6-mm-long mini-screws when placed with the engine driver. The overall success rate was also significantly higher in the maxilla (p < 0.05) when the engine driver was used. Success rates were similar among all age groups regardless of the insertion method used. Conclusions: Taken together, the motor-driven insertion method can be helpful to get a higher success rate of orthodontic mini-screw placement.

Abstract

Objective: The aim of this study was to compare the success rates of the manual and motor-driven mini-screw insertion methods according to age, gender, length of mini-screws, and insertion sites. Methods: We retrospectively reviewed 429 orthodontic mini-screw placements in 286 patients (102 in men and 327 in women) between 2005 and 2010 at private practice. Age, gender, mini-screw length, and insertion site were cross-tabulated against the insertion methods. The Cochran-Mantel-Haenszel test was performed to compare the success rates of the 2 insertion methods. Results: The motor-driven method was used for 228 mini-screws and the manual method for the remaining 201 mini-screws. The success rates were similar in both men and women irrespective of the insertion method used. With respect to mini-screw length, no difference in success rates was found between motor and hand drivers for the 6-mm-long mini-screws (68.1% and 69.5% with the engine driver and hand driver, respectively). However, the 8-mm-long mini-screws exhibited significantly higher success rates (90.4%, p < 0.01) than did the 6-mm-long mini-screws when placed with the engine driver. The overall success rate was also significantly higher in the maxilla (p < 0.05) when the engine driver was used. Success rates were similar among all age groups regardless of the insertion method used. Conclusions: Taken together, the motor-driven insertion method can be helpful to get a higher success rate of orthodontic mini-screw placement.

참고문헌 (40)

  1. 김태우, "Clinical Application of Orthodontic Mini-implant" (2008), Myung Mun Publishing
  2. Nanda R, "Temporary anchorage devices in orthodontics" (2009), Mosby Elsevier
  3. Park HS, "Orthodontic treatment using micro-implant.2nd ed" (2006), Daehan Narae Publishing
  4. Baumgaertel S, "Mini-implant anchorage for the orthodontic practitioner", Am J Orthod Dentofacial Orthop, 133, pp.621~627 (2008)
  5. Chen CH, "The use of microimplants in orthodontic anchorage", J Oral Maxillofac Surg, 64, pp.1209~1213 (2006)
  6. 박효상, "교정치료 고정원으로서 Microscrew implants의 성공율에 대한 임상적 연구", 대한치과교정학회지, 33(3), pp.151~156 (2003), 대한치과교정학회
  7. Heidemann W, "Analysis of the osseous", metal interface of drill free screws and self-tapping screws, 2001, pp.29, 69~74
  8. Heidemann W, "Drill free screws: a new form of osteosynthesis screw", J Craniomaxillofac Surg, 26, pp.163~168 (1998)
  9. Cohen S, "Pathways of the pulp. 9th ed" (2006), Mosby Elsevier
  10. Eriksson RA, "Temperatures during drilling for the placement of implants using the osseointegration technique", J Oral Maxillofac Surg, 44, pp.4~7 (1986)
  11. Nam OH, "Effect of heat production on alvolar bone surface by ratating speedand virtual preessure of micro-implant drill", pp.2004
  12. Eriksson AR, "Temperature threshold levels for heat-induced bone tissue injury: a vitalmicroscopic study in the rabbit", J Prosthet Dent, 50, pp.101~107 (1983)
  13. Matthews LS, "Temperatures measured in human cortical bone when drilling", J Bone Joint Surg Am, 54, pp.297~308 (1972)
  14. Park HS, "Factors affecting the clinical success of screw implants used as orthodontic anchorage", Am J Orthod Dentofacial Orthop, 130, pp.18~25 (2006)
  15. Luzi C, "Guidelines for success in placement of orthodontic mini-implants", J Clin Orthod, 43, pp.39~44 (2009)
  16. Moon CH, "Factors associated with the success rate of orthodontic miniscrews placed in the upper and lower posterior buccal region", Angle Orthod, 78, pp.101~106 (2008)
  17. Miyawaki S, "Factors associated with the stability of titanium screws placed in the posterior region for orthodontic anchorage", Am J Orthod Dentofacial Orthop, 124, pp.373~378 (2003)
  18. Kuroda S, "Clinical use of miniscrew implants as orthodontic anchorage: success rates and postoperative discomfort", Am J Orthod Dentofacial Orthop, 131, pp.9~15 (2007)
  19. Lim HJ, "Predictors of initial stability of orthodontic miniscrew implants", Eur J Orthod, 33, pp.528~532 (2011)
  20. Cheng SJ, "A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage", Int J Oral Maxillofac Implants, 19, pp.100~106 (2004)
  21. Lim HJ, "Factors associated with initial stability of miniscrews for orthodontic treatment", Am J Orthod Dentofacial Orthop, 136, pp.236~242 (2009)
  22. 김영균, "미니 임플란트 시스템의 적용에 대한 다기관 후향적 임상연구", 대한구강악안면외과학회지, 36(4), pp.325~330 (2010), 대한구강악안면외과학회
  23. Crismani AG, "Miniscrews in orthodontic treatment: review and analysis of published clinical trials", Am J Orthod Dentofacial Orthop, 137, pp.108~113 (2010)
  24. Motoyoshi M, "Recommended placement torque when tightening an orthodontic mini-implant", Clin Oral Implants Res, 17, pp.109~114 (2006)
  25. Liou EJ, "Do miniscrews remain stationary under orthodontic forces?", Am J Orthod Dentofacial Orthop, 126, pp.42~47 (2004)
  26. Fritz U, "Clinical suitability of titanium microscrews for orthodontic anchorage-preliminary experiences", J Orofac Orthop, 65, pp.410~418 (2004)
  27. Park HS, "Group distal movement of teeth using microscrew implant anchorage", Angle Orthod, 75, pp.602~609 (2005)
  28. Tseng YC, "The application of mini-implants for orthodontic anchorage", Int J Oral Maxillofac Surg, 35, pp.704~707 (2006)
  29. Herman RJ, "Mini-implant anchorage for maxillary canine retraction: a pilot study", Am J Orthod Dentofacial Orthop, 130, pp.228~235 (2006)
  30. Wiechmann D, "Success rate of mini- and micro-implants used for orthodontic anchorage: a prospective clinical study", Clin Oral Implants Res, 18, pp.263~267 (2007)
  31. Motoyoshi M, "Application of orthodontic mini-implants in adolescents", Int J Oral Maxillofac Surg, 36, pp.695~699 (2007)
  32. Chen YJ, "A retrospective analysis of the failure rate of three different orthodontic skeletal anchorage systems", Clin Oral Implants Res, 18, pp.768~775 (2007)
  33. 임선아, "교정용 미니스크류의 형상에 따른 식립 토오크의 비교", 대한치과교정학회지, 37(2), pp.87~97 (2007), 대한치과교정학회
  34. Kravitz ND, "Risks and complications of orthodontic miniscrews", Am J Orthod Dentofacial Orthop, 131(4 Suppl), pp.S43~S51 (2007)
  35. Yared GM, "Failure of ProFile instruments used with high and low torque motors", Int Endod J, 34, pp.471~475 (2001)
  36. Gambarini G, "Rationale for the use of low-torque endodontic motors in root canal instrumentation", Endod Dent Traumatol, 16, pp.95~100 (2000)
  37. Jo WH, "Influence of the operator’s experience and drilling sites on the root contact during the drilling for micro-implants insertion", pp.2005
  38. Matsuoka M, "Friction heat during selfdrilling of an orthodontic miniscrew", Int J Oral Maxillofac Surg, 40, pp.191~194 (2011)
  39. 박진서, "Self-drilling 방식의 마이크로임플란트 식립에 의해 발생하는 피질골 스트레인의 유한요소해석", 대한치과교정학회지, 39(4), pp.203~212 (2009), 대한치과교정학회
  40. 유원재, "교정용 마이크로 임플란트의 경부와 인접한 치밀골의 계면조건이 골응력에 미치는 영향에 대한 유한요소해석적 연구", 대한치과기재학회지, 33(4), pp.381~393 (2006), 대한치과기재학회

관련 논문AI추천

Prognostic factors associated with the success rates of posterior orthodontic miniscrew implants: A subgroup meta-analysisBudiKusnoto, Ellen A BeGole, Eun-Jeong Kim, Hoi-Jeong Lim, Hyeon-Shik Hwang, Sung-Bin Hong대한치과교정학회 · 대한치과교정학회지2016 · 제46권 제2호Effect of a miniscrew surgical guide on the success rate and root proximity of orthodontic miniscrews: A retrospective cohort studyDasomi Kim, Eun-Hack Andrew Choi, Hyung-Seog Yu, Jung-Yul Cha, Liu Jing, Sung-Hwan Choi대한치과교정학회 · 대한치과교정학회지2025 · 제55권 제3호Analysis of time to failure of orthodontic mini-implants after insertion or loading김영균, 김종완, 김태우, 이남기, 이종호, 정종화대한구강악안면외과학회 · 대한구강악안면외과학회지2015 · 제41권 제5호Influence of late removal after treatment on the removal torque of microimplants김호진, Park Hyo-Sang대한치과교정학회 · 대한치과교정학회지2022 · 제52권 제3호Evaluation of factors influencing the success rate of orthodontic microimplants using panoramic radiographs김미정, 박재현, 이근영, 장나영, 채종문, R. Curtis Bay대한치과교정학회 · 대한치과교정학회지2018 · 제48권 제1호The effects of different pilot-drilling methods on the mechanical stability of a mini-implant system at placement and removal: a preliminary study김덕수, 김성균, 김성훈, 정규림, HyeRan Choo, Il-Sik Cho, John C. Huang, Yun-Seob Shin대한치과교정학회 · 대한치과교정학회지2011 · 제41권 제5호

이 간행물의 다른 논문 (7건)