본문 바로가기
KERD
논문KCI 등재

Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective: This study was conducted to perform histomorphometric evaluations of the bone surrounding orthodontic miniscrews according to their proximity to the adjacent tooth roots in the posterior mandible of beagle dogs. Methods: Four male beagle dogs were used for this study. Six orthodontic miniscrews were placed in the interradicular spaces in the posterior mandible of each dog (n = 24). The implanted miniscrews were classified into no loading, immediate loading, and delayed loading groups according to the loading time. At 6 weeks after screw placement, the animals were sacrificed, and tissue blocks including the miniscrews were harvested for histological examinations. After analysis of the histological sections, the miniscrews were categorized into three additional groups according to the root proximity: high root proximity, low root proximity, and safe distance groups. Differences in the bone–implant contact (BIC, %) among the root proximity groups and loading time groups were determined using statistical analyses. Results: No BIC was observed within the bundle bone invaded by the miniscrew threads. Narrowing of the periodontal ligament space was observed in cases where the miniscrew threads touched the bundle bone. BIC (%) was significantly lower in the high root proximity group than in the low root proximity and safe distance groups. However, BIC (%) showed no significant differences among the loading time groups. Conclusions: Regardless of the loading time, the stability of an orthodontic miniscrew is decreased if it is in contact with the bundle bone as well as the adjacent tooth root.

Abstract

Objective: This study was conducted to perform histomorphometric evaluations of the bone surrounding orthodontic miniscrews according to their proximity to the adjacent tooth roots in the posterior mandible of beagle dogs. Methods: Four male beagle dogs were used for this study. Six orthodontic miniscrews were placed in the interradicular spaces in the posterior mandible of each dog (n = 24). The implanted miniscrews were classified into no loading, immediate loading, and delayed loading groups according to the loading time. At 6 weeks after screw placement, the animals were sacrificed, and tissue blocks including the miniscrews were harvested for histological examinations. After analysis of the histological sections, the miniscrews were categorized into three additional groups according to the root proximity: high root proximity, low root proximity, and safe distance groups. Differences in the bone–implant contact (BIC, %) among the root proximity groups and loading time groups were determined using statistical analyses. Results: No BIC was observed within the bundle bone invaded by the miniscrew threads. Narrowing of the periodontal ligament space was observed in cases where the miniscrew threads touched the bundle bone. BIC (%) was significantly lower in the high root proximity group than in the low root proximity and safe distance groups. However, BIC (%) showed no significant differences among the loading time groups. Conclusions: Regardless of the loading time, the stability of an orthodontic miniscrew is decreased if it is in contact with the bundle bone as well as the adjacent tooth root.

참고문헌 (31)

  1. Liou EJ, "Do miniscrews remain stationary under orthodontic forces?", Am J Orthod Dentofacial Orthop, 126, pp.42~47 (2004)[DOI]
  2. Kravitz ND, "Risks and complications of orthodontic miniscrews", Am J Orthod Dentofacial Orthop, 131(4 Suppl), pp.S43~S51 (2007)[DOI]
  3. Wang YC, "Comparison of the loading behavior of self-drilling and predrilled miniscrews throughout orthodontic loading", Am J Orthod Dentofacial Orthop, 133, pp.38~43 (2008)[DOI]
  4. Papageorgiou SN, "Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis", Am J Orthod Dentofacial Orthop, 142, pp.577~595 (2012)[DOI]
  5. Kang YG, "Stability of mini-screws invading the dental roots and their impact on the paradental tissues in beagles", Angle Orthod, 79, pp.248~255 (2009)[DOI]
  6. Asscherickx K, "Success rate of miniscrews relative to their position to adjacent roots", Eur J Orthod, 30, pp.330~335 (2008)[DOI]
  7. Kuroda S, "Root proximity is a major factor for screw failure in orthodontic anchorage", Am J Orthod Dentofacial Orthop, 131(4 Suppl), pp.S68~S73 (2007)[DOI]
  8. Kim SH, "Cone-beam computed tomography evaluation of mini-implants after placement: Is root proximity a major risk factor for failure?", Am J Orthod Dentofacial Orthop, 138, pp.264~276 (2010)[DOI]
  9. Janson G, "Influence of miniscrew dental root proximity on its degree of late stability", Int J Oral Maxillofac Surg, 42, pp.527~534 (2013)[DOI]
  10. Wang Z, "A quantitative anatomical study on posterior mandibular interradicular safe zones for miniscrew implantation in the beagle", Ann Anat, 190, pp.252~257 (2008)[DOI]
  11. Deguchi T, "Histomorphometric evaluation of cortical bone thickness surrounding miniscrew for orthodontic anchorage", Clin Implant Dent Relat Res, 13, pp.197~205 (2011)[DOI]
  12. Cha JY, "Miniscrew stability evaluated with computerized tomography scanning", Am J Orthod Dentofacial Orthop, 137, pp.73~79 (2010)[DOI]
  13. Marquezan M, "Is trabecular bone related to primary stability of miniscrews?", Angle Orthod, 84, pp.500~507 (2014)[DOI]
  14. 이승연, "교정력 부하시기에 따른 교정용 미니 임플란트의 안정성", 대한치과교정학회지, 38(3), pp.149~158 (2008), 대한치과교정학회
  15. Freire JN, "Histomorphologic and histomophometric evaluation of immediately and early loaded mini-implants for orthodontic anchorage", Am J Orthod Dentofacial Orthop, 131, pp.704.e1~704.e9 (2007)
  16. Ure DS, "Stability changes of miniscrew implants over time", Angle Orthod, 81, pp.994~1000 (2011)[DOI]
  17. Motoyoshi M, "Clinical indices for orthodontic mini implants", J Oral Sci, 53, pp.407~412 (2011)[DOI]
  18. Woods PW, "The effect of force, timing, and location on bone-to-implant contact of miniscrew implants", Eur J Orthod, 31, pp.232~240 (2009)[DOI]
  19. Youn JW, "Biologic evaluation of a hollow-type miniscrew implant: an experimental study in beagles", Am J Orthod Dentofacial Orthop, 145, pp.626~637 (2014)[DOI]
  20. Cho YM, "The effect of rotation moment on the stability of immediately loaded orthodontic miniscrews: a pilot study", Eur J Orthod, 32, pp.614~619 (2010)[DOI]
  21. Watanabe H, "Orthodontic miniscrew failure rate and root proximity, insertion angle, bone contact length, and bone density", Orthod Craniofac Res, 16, pp.44~55 (2013)[DOI]
  22. Nanci A, "Ten cate's oral histology: development and function", pp.220~ (2012), Elsevier Mosby
  23. Araujo M, "Clinical periodontology and implant dentistry", pp.53~63 (2003), Blackwell Munksgaard
  24. Hubar JS, "Quantification of the lamina dura", J Can Dent Assoc, 59, pp.997~1000 (1993)
  25. Buchter A, "Load-related bone modelling at the interface of orthodontic microimplants", Clin Oral Implants Res, 17, pp.714~722 (2006)[DOI]
  26. Kim H, "Histologic evaluation of rootsurface healing after root contact or approximation during placement of mini-implants", Am J Orthod Dentofacial Orthop, 139, pp.752~760 (2011)[DOI]
  27. Lee YK, "Root and bone response to the proximity of a miniimplant under orthodontic loading", Angle Orthod, 80, pp.452~458 (2010)[DOI]
  28. Brisceno CE, "Healing of the roots and surrounding structures after intentional damage with miniscrew implants", Am J Orthod Dentofacial Orthop, 135, pp.292~301 (2009)[DOI]
  29. 박효상, "Self drilling과 Self-tapping microscrew implants의 조직학적 및 생역학적인 비교", 대한치과교정학회지, 36(4), pp.295~307 (2006), 대한치과교정학회
  30. Cha JY, "Strain of bone-implant interface and insertion torque regarding different miniscrew thread designs using an artificial bone model", Eur J Orthod, 37, pp.268~274 (2015)[DOI]
  31. 최혜원, "Comparison of mechanical and biological properties of zirconia and titanium alloy orthodontic micro-implants", 대한치과교정학회지, 47(4), pp.229~237 (2017), 대한치과교정학회

관련 논문AI추천

Histologic assessment of the biological effects after speedy surgical orthodontics in a beagle animal model: a preliminary study김성훈, 정규림, Hong-Suk Kim, HyeRan Choo, Yoon-Goo Kang, Young-Guk Park, Young-Jun Lee대한치과교정학회 · 대한치과교정학회지2011 · 제41권 제5호Effects of orthodontic force on root surface damage caused by contact with temporary anchorage devices and on the repair processÖzge Çelik Güler, Sıddık Malkoç대한치과교정학회 · 대한치과교정학회지2019 · 제49권 제2호Analysis of time to failure of orthodontic mini-implants after insertion or loading김영균, 김종완, 김태우, 이남기, 이종호, 정종화대한구강악안면외과학회 · 대한구강악안면외과학회지2015 · 제41권 제5호Root proximity of the anchoring miniscrews of orthodontic miniplates in the mandibular incisal area: Cone-beam computed tomographic analysisChoi Yong-Suk, Choo HyeRan, Hwang Eui-Hwan, Jeong Do-Min, Kim Seong-Hun, Lee Jin-Suk, Oh Song Hee대한치과교정학회 · 대한치과교정학회지2021 · 제51권 제4호Qualitative and quantitative evaluation of root injury risk potentially burdening insertion of miniscrew implants박효상, Beata Kawala, Bjorn Ludwig, Joanna Antoszewska, Paulina Trześniewska대한치과교정학회 · 대한치과교정학회지2011 · 제41권 제2호Self drilling과 Self-tapping microscrew implants의 조직학적 및 생역학적인 비교박효상, 정성화, Shue Yen대한치과교정학회 · 대한치과교정학회지2006 · 제36권 제4호

이 간행물의 다른 논문 (8건)