CT 영상 기반 집속 초음파 시뮬레이션 모델의 불균질 물성과 균질 물성에 따른 모델 분석 결과 비교

Comparison of Analysis Results According to Heterogeneous or Homogeneous Model for CT-based Focused Ultrasound Simulation

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Purpose: Focused ultrasound is an emerging technology for treating the brain locally in a noninvasive man- ner. In this study, we have investigated the influence of skull properties on simulating transcranial pressure field. Methods: A 3D computational model of transcranial focused ultrasound was constructed using female and male CT data to solve for intracranial pressure. For heterogeneous model, the acoustic properties were calculated from CT Hounsfield units based on a porosity. The homogeneous model assigned constant acoustic properties for the single- layered skull. Results: A computational model was validated against empirical data. The homogeneous models were then compared with the heterogeneous model, resulted in 10.87% and 7.19% differences in peak pressure for female and male models respectively. For the focal volume, homogeneous model demonstrated more than 94% overlap com- pared with the heterogeneous model. Conclusion: Homogeneous model can be constructed using MR images that are commonly used for the segmentation of the skull. We propose the possibility of the homogeneous model for the simulating transcranial pressure field owing to comparable focal volume between homogeneous model and hetero- geneous model.

Abstract

Purpose: Focused ultrasound is an emerging technology for treating the brain locally in a noninvasive man- ner. In this study, we have investigated the influence of skull properties on simulating transcranial pressure field. Methods: A 3D computational model of transcranial focused ultrasound was constructed using female and male CT data to solve for intracranial pressure. For heterogeneous model, the acoustic properties were calculated from CT Hounsfield units based on a porosity. The homogeneous model assigned constant acoustic properties for the single- layered skull. Results: A computational model was validated against empirical data. The homogeneous models were then compared with the heterogeneous model, resulted in 10.87% and 7.19% differences in peak pressure for female and male models respectively. For the focal volume, homogeneous model demonstrated more than 94% overlap com- pared with the heterogeneous model. Conclusion: Homogeneous model can be constructed using MR images that are commonly used for the segmentation of the skull. We propose the possibility of the homogeneous model for the simulating transcranial pressure field owing to comparable focal volume between homogeneous model and hetero- geneous model.

참고문헌 (23)

  1. Mueller J, "Transcra-nial focused ultrasound modulates intrinsic and evoked EEG dynamics", Brain stimulation, 7(6), pp.900~908 (2014)
  2. Legon W, "Neuromodulation with single-element transcranial focused ultrasound in human thalamus", Human brain mapping, 39(5), pp.1995~2006 (2018)
  3. Lee W, "Image-guided transcranial focused ultrasound stimulates human primary somatosensory cortex", Scientific reports, 5(1), pp.1~10 (2015)
  4. Samoudi MA, "Compu tational modeling of a single-element transcranial focused ultrasound transducer for subthalamic nucleus stimulation", Journal of neural engineering, 16(2), pp.026015~ (2019)
  5. Mueller JK, "Computational explo-ration of wave propagation and heating from transcranial focused ultrasound for neuromodulation", Journal of neural engineering, 13(5), pp.056002~ (2016)
  6. Park TY, "Method to optimize the placement of a single-element transducer for transcranial focused ultra-sound", Computer methods and programs in biomedicine, 179, pp.104982~ (2019)
  7. Huiskamp G, "The need for correct realistic geometry in the inverse EEG problem", IEEE Transactions on Biomedical Engineering, 46(11), pp.1281~1287 (1999)
  8. Montes-Restrepo V, "Influence of skull modeling approaches on EEG source localization", Brain topography, 27(1), pp.95~111 (2014)
  9. Park TY, "Method to optimize the placement of a single-element transducer for transcranial focused ultra-sound", Computer methods and programs in biomedicine, 179, pp.104982~ (2019)
  10. Clement G, "Correlation of ultrasound phase with physical skull properties", Ultrasound in medicine & biology, 28(5), pp.617~624 (2002)
  11. Jones RM, "Comparison of analytical and numerical approaches for CT-based aberration correction in transcranial passive acoustic imaging", Physics in Medicine & Biology, 61(1), pp.23~ (2015)
  12. Deffieux T, "Numerical study of a simple transcranial focused ultrasound system applied to blood-brain barrier opening", IEEE transactions on ultrasonics, ferroelec-trics, and frequency control, 57(12), pp.2637~2653 (2010)
  13. Seo H, "Numerical Evaluation of the Effects of Transducer Displacement on Transcranial Focused Ultrasound in the Rat Brain", Brain sciences, 12(2), pp.216~ (2022)
  14. Constans C, "Potential impact of thermal effects during ultrasonic neurostimulation : retro-spective numerical estimation of temperature elevation in seven rodent setups", Physics in Medicine & Biology, 63(2), pp.025003~ (2018)
  15. De Angelis A, "Computational optimization of transcranial focused ultrasound stimulation : Toward noninvasive, selective stim-ulation of deep brain structures", Applied Physics Letters, 118(23), pp.233702~ (2021)
  16. Salahshoor H, "Transcranial focused ultrasound generates skull-conducted shear waves : Computa"tional model and implications for neuromodulation", Applied Physics Letters, 117(3), pp.033702~ (2020)
  17. Spitzer VM, "The Visible Human Dataset : the anatomical platform for human simulation", The Anatomical Record : An Official Publication of the American Association of Anatomists, 253(2), pp.49~57 (1998)
  18. Cox BT, "k-space propagation models for acoustically heterogeneous media : Application to biomedical photoacoustics", The Journal of the Acoustical Society of America, 121(6), pp.3453~3464 (2007)
  19. Mueller JK, "Numerical evaluation of the skull for human neuromodulation with transcranial focused ultrasound", Journal of neural engineering, 14(6), pp.066012~ (2017)
  20. Legon W, "Transcra-nial focused ultrasound neuromodulation of the human pri-mary motor cortex", Scientific reports, 8(1), pp.1~14 (2018)
  21. Koh H, "Acoustic sim-ulation for transcranial focused ultrasound using GAN-based synthetic CT", IEEE Journal of Biomedical and Health Infor-matics, 26(1), pp.161~171 (2021)
  22. Farcito S, "Accurate anatomical head segmentations:a data set for biomedical simulations", 41st Annual Interna-tional Conference of the IEEE Engineering in Medicine an

관련 논문AI추천

이 간행물의 다른 논문 (9건)