집속초음파 자극기의 성능평가를 위한 팬텀 내부온도 측정
Measurement of Internal Temperature Distribution for the Evaluation of Focused Ultrasound (FUS) Stimulation Devices
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This research is to measure real-time temperature distribution inside a tissue-mimicking phantom for the safety and effectiveness evaluations of focused ultrasound (FUS) device capable of linear scanning stimulation. Since the focusing area of the FUS stimulation device is smaller than diameter of conventional thermal probe and keeps moving, it is impossible to monitor temperature distribution inside the phantom. By using the phantom with a thin film temperature sensor array inserted, real-time temperature change caused by the FUS device was measured. The translation of the measured temperature peak was also tracked successfully. The present phantom had been exper- imentally proven to be applicable to validate the performance and safety of the therapeutic ultrasound devices.
Abstract
This research is to measure real-time temperature distribution inside a tissue-mimicking phantom for the safety and effectiveness evaluations of focused ultrasound (FUS) device capable of linear scanning stimulation. Since the focusing area of the FUS stimulation device is smaller than diameter of conventional thermal probe and keeps moving, it is impossible to monitor temperature distribution inside the phantom. By using the phantom with a thin film temperature sensor array inserted, real-time temperature change caused by the FUS device was measured. The translation of the measured temperature peak was also tracked successfully. The present phantom had been exper- imentally proven to be applicable to validate the performance and safety of the therapeutic ultrasound devices.
참고문헌 (14)
- Mirjam CL Peek, "High-intensity focused ultrasound in the treatment of breast tumours", ecancermedicalscience, 12 (2018), Ecancer Global Foundation[DOI]
- Nicholas Kotewall, "High-intensity focused ultrasound ablation as a treatment for benign thyroid diseases: the present and future", ULTRASONOGRAPHY, 38(2), pp.135~142 (2019), 대한초음파의학회[DOI]
- Yi-Hsuan Hsiao, "Clinical Application of High-intensity Focused Ultrasound in Cancer Therapy", Journal of Cancer, 7(3), pp.225~231 (2016), Ivyspring International Publisher[DOI]
- Zahra Izadifar, "An Introduction to High Intensity Focused Ultrasound: Systematic Review on Principles, Devices, and Clinical Applications", Journal of Clinical Medicine, 9(2), pp.460~ (2020), MDPI AG[DOI]
- 최진우, "Portable high-intensity focused ultrasound system with 3D electronic steering, real-time cavitation monitoring, and 3D image reconstruction algorithms: a preclinical study in pigs", ULTRASONOGRAPHY, 33(3), pp.191~199 (2014), 대한초음파의학회
- 유우진, "초음파 치료의 효율성 향상을 위한 초음파 온열 시뮬레이터 개발", 의공학회지, 30(5), pp.418~427 (2009), 대한의용생체공학회
- "고강도집속형초음파수술기 허가심사 가이드라인", 식품의약품안전평가원, ~ (2017)
- "집속형초음파자극시스템 허가심사가이드라인", 식품의약품안전평가원, ~ (2021)
- Sim JK, "Thin-film resis-tance temperature detector array for the measurement of tem-perature distribution inside a phantom", Metrologia, 55(1), pp.5~11 (2018)
- Samiudin NM, Yang I, Kim YT, Doh I, "Focused Ultrasound Thermometry: A Two-Dimensional Resistance Temperature Detector Array in a Tissue-Mimicking Material", IEEE Sens. J, 21(22), pp.25624~25631 (2021)
- Daniel (Jai Kyoung) Sim, "Portable Skin Analyzers with Simultaneous Measurements of Transepidermal Water Loss, Skin Conductance and Skin Hardness", Sensors, 19(18), pp.3857~ (2019), MDPI AG[DOI]
- A. Cafarelli, "Speed of sound in rubber-based materials for ultrasonic phantoms", Journal of Ultrasound, 19(4), pp.251~256 (2016), Springer Science and Business Media LLC[DOI]
- Monika Golda-Cepa, "Recent progress on parylene C polymer for biomedical applications: A review", Progress in Organic Coatings, 140, pp.105493~ (2020), Elsevier BV[DOI]