인공지능을 활용한 초음파영상진단장치에서 초음파 팬텀 영상을 이용한 정도관리의 정량적 평가방법 연구
A Study on the Quantitative Evaluation Method of Quality Control using Ultrasound Phantom in Ultrasound Imaging System based on Artificial Intelligence
1
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Ultrasound examination using ultrasound equipment is an ultrasound device that images human organs using sound waves and is used in various areas such as diagnosis, follow-up, and treatment of diseases. However, if the quality of ultrasound equipment is not guaranteed, the possibility of misdiagnosis increases, and the diagnosis rate decreases. Accordingly, The Korean Society of Radiology and Korea society of Ultrasound in Medicine presented guidelines for quality management of ultrasound equipment using ATS-539 phantom. The DenseNet201 classification algorithm shows 99.25% accuracy and 5.17% loss in the Dead Zone, 97.52% loss in Axial/Lateral Resolution, 96.98% accuracy and 20.64% loss in Sensitivity, 93.44% accuracy and 22.07% loss in the Gray scale and Dynamic Range. As a result, it is the best and is judged to be an algorithm that can be used for quantitative evaluation. Through this study, it can be seen that if quantitative evaluation using artificial intelligence is conducted in the qualitative eval- uation item of ultrasonic equipment, the reliability of ultrasonic equipment can be increased with high accuracy.
Abstract
Ultrasound examination using ultrasound equipment is an ultrasound device that images human organs using sound waves and is used in various areas such as diagnosis, follow-up, and treatment of diseases. However, if the quality of ultrasound equipment is not guaranteed, the possibility of misdiagnosis increases, and the diagnosis rate decreases. Accordingly, The Korean Society of Radiology and Korea society of Ultrasound in Medicine presented guidelines for quality management of ultrasound equipment using ATS-539 phantom. The DenseNet201 classification algorithm shows 99.25% accuracy and 5.17% loss in the Dead Zone, 97.52% loss in Axial/Lateral Resolution, 96.98% accuracy and 20.64% loss in Sensitivity, 93.44% accuracy and 22.07% loss in the Gray scale and Dynamic Range. As a result, it is the best and is judged to be an algorithm that can be used for quantitative evaluation. Through this study, it can be seen that if quantitative evaluation using artificial intelligence is conducted in the qualitative eval- uation item of ultrasonic equipment, the reliability of ultrasonic equipment can be increased with high accuracy.
참고문헌 (22)
- 김상명, "응급실에 내원한 급성 관상동맥 증후군이 의심되는 환자들에게 응급의학과 의사가 시행한 경흉부 심초음파의 효용성", 대한응급의학회지, 31(6), pp.553~561 (2020), 대한응급의학회
- Sipilä O, "Quality assurance in diag"nostic ultrasound", European journal of radiology, 80(2), pp.519~525 (2011)
- Marik PE, "Certification and training in critical care ultrasound", pp.215~217 (2008), Springer
- 임창선, "한국 방사선사의 초음파진단검사 직무역량에 관한 고찰", 한국방사선학회논문지, 13(6), pp.857~864 (2019), 한국방사선학회[DOI]
- Liu H, "Dif-ferentiation of benign and malignant sub-1-cm breast lesions using contrast-enhanced sonography", J Ultrasound Med, 34(1), pp.117~123 (2015)
- 김표년, "ATS-539 다목적 초음파팬텀을 이용한 초음파영상진단장치의 성능평가", 대한영상의학회지, 58(5), pp.533~541 (2008), 대한영상의학회
- Young-kwon Cho, "Quality Evaluation of Ultrasonographic Equipment Using an ATS-539 Multipurpose Phantom in Veterinary Medicine", 한국임상수의학회지, 39(3), pp.114~120 (2022), 한국임상수의학회[DOI]
- Kim SJ, "Problem and improvement devices of ultrasound imaging quality control using ultrasound phantom", The Korean Society of Medical Sonographers, 1(1), pp.13~19 (2010)
- 김민주, "ATS-539 다목적 팬텀과 SNR을 이용한 초음파 영상평가", 한국콘텐츠학회 논문지, 13(8), pp.284~291 (2013), 한국콘텐츠학회[DOI]
- Kim YM, "The Development of Quality Control Program for Ultrasonographic Equipment", pp.2013
- Usman AG, "Artificial intelli-gence-based models for the qualitative and quantitative pre-diction of aphytochemical compound using HPLC method", Turkish Journal of Chemistry, 44(5), pp.1339~1351 (2020)
- Yoon SH, "Method for analyzing the relationship betweeQuantitative and Qualitative Data for Data Driven UX Design", Jourmal of the HCI Society of Korea, 15(4), pp.17~
- Alzubaidi L, "Review of deep learning : Concepts, CNN architectures, challenges, applications, future directions", Journal of big Data, 8(1), pp.1~74 (2021)
- Jo YB, "When evaluating the Dynamic Range items of the Ultra sound image ATS-539phantom Evaluation Comparison Using Artificial Intelligence", The Korean Society of Medical Sonographers, 5, pp.91~92 (2021)
- Affolter R, "Apply-ing augmented reality during a forensic autopsy—Microsoft HoloLens as a DICOM viewer", Journal of Forensic Radiology and Imaging, 16, pp.5~8 (2019)
- Smolka W, "Changes in the volume and density of calvarial split bone grafts after alveolar ridge augmentation", Clinical oral implants research, 17(2), pp.149~155 (2006)
- Ketkar N, "Introduction to keras", pp.97~111 (2017), Springer
- Tian C, "Attention-guided CNN for image denoising", Neural Networks, 124, pp.117~129 (2020)
- MOHW, "특수의료장비의 설치 및 품질관리에 관한 규칙", 보건복지부령 제817호, ~ (2021)
- Altenstetter C, "Medical device regulation in the European Union, Japan and the United States. Commonalities, differ-ences and challenges", Innovation: The European Journal of Social Science Research, 25(4), pp.362~388 (2012)
- Kim YJ, "Certification of diagnostic imaging equipment in Australia-diagnostic imaging accreditation scheme", HIRA, ~ (2020)
- Son YN, "Effect of Coverage Expansion Policy for an Ultra-sonography in the Upper Abdomen on Its Utilization: A Dif-ference-in-Difference Mixed-Effects Model Analysis", Health Policy and Management, 30(3), pp.326~