치과용 임플란트 식립에 사용되는 핸드피스의 윤활제가 생체내 미치는 영향
Influence of Rotary Instrument Mineral Oil Lubricant on the Handpiece for Dental Implant: In Vitro and In Vivo Study
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose: The purpose of this study was to evaluate the effect of oil lubricant for dental handpiece and to investigate the relationship to the prognosis of dental implants. Materials and Methods: An experiment was conducted on the residual amount of lubricant in the handpiece and the amount of lubricant that will remain in the fixture after drilling. Based on the data, biocompatibility was assessed through the assessment of cytotoxicity with L929 cells and 33 SD rats. This experiment was conducted through an 8 mm-long, 3.5 mm-diameter fixture(Osstem implant Co., Ltd., Korea) and lubricant(KaVo Dental GmbH., Germany) for handpiece. Results: The amount of lubricants in the handpiece decreased with the removal phase, but some of them could be confirmed to remain. In the cytotoxicity assessment, the survival rate was lower over 100 ppm. In experiments with SD rat, there was no significant difference among groups. Conclusion: The surface of the dental implants could be contaminated from some leftover lubricants in the handpiece. Although the lubricant is the biocompatible in cytotoxicity test and SD rat test, it does not mean it has no effect on osseointegration.
Abstract
Purpose: The purpose of this study was to evaluate the effect of oil lubricant for dental handpiece and to investigate the relationship to the prognosis of dental implants. Materials and Methods: An experiment was conducted on the residual amount of lubricant in the handpiece and the amount of lubricant that will remain in the fixture after drilling. Based on the data, biocompatibility was assessed through the assessment of cytotoxicity with L929 cells and 33 SD rats. This experiment was conducted through an 8 mm-long, 3.5 mm-diameter fixture(Osstem implant Co., Ltd., Korea) and lubricant(KaVo Dental GmbH., Germany) for handpiece. Results: The amount of lubricants in the handpiece decreased with the removal phase, but some of them could be confirmed to remain. In the cytotoxicity assessment, the survival rate was lower over 100 ppm. In experiments with SD rat, there was no significant difference among groups. Conclusion: The surface of the dental implants could be contaminated from some leftover lubricants in the handpiece. Although the lubricant is the biocompatible in cytotoxicity test and SD rat test, it does not mean it has no effect on osseointegration.
참고문헌 (35)
- Adell R, "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw", Int J Oral Surg, 10(6), pp.387~416 (1981)
- Albrektsson T, "The long-term efficacy of currently used dental implants : a review and proposed criteria of success", Int J Oral Maxillofac Implants, 1(1), pp.11~25 (1986)
- Zhao G, "High surface energy enhances cell response to titanium substrate microstructure", J Biomed Mater Res A, 74(1), pp.49~58 (2005)
- Liu X, "Influence of substratum surface chemistry", energy and topography on the human fetal osteoblastic cell line hFOB 1.19: phenotypic and genotypic responses observed in vitro, 2007, pp.28(31), 4535~4550
- Zareidoost A, "The relationship of surface roughness and cell response of chemical surface modification of titanium", J Mater Sci Mater Med, 23(6), pp.1479~1488 (2012)
- Carmagnola D, "Bone tissue reaction around implants placed in a compromised jaw", J Clin Periodontol, 26(10), pp.629~635 (1999)
- Al-Sayyed A, "Predictable crestal bone remodelling around two porous‐coated titanium alloy dental implant designs. A radiographic study in dogs", Clin Oral Implants Res, 5(3), pp.131~141 (1994)
- Lundgren A, "Influence of surface roughness of barrier walls on guided bone augmentation : experimental study in rabbits", Clin Implant Dent Relat Res, 1(1), pp.41~48 (1999)
- Att W, "Effect of supramicron roughness characteristics produced by 1-and 2-step acid etching on the osseointegration capability of titanium", Int J Oral Maxillofac Implants, 22(5), pp.719~728 (2007)
- Holtorf HL, "Ectopic bone formation in rat marrow stromal cell", titanium fiber mesh scaffold constructs : effect of initial cell phenotype, 2005, pp.26(31), 6208~6216
- Khang D, "The role of nanometer and sub-micron surface features on vascular and bone cell adhesion on titanium", Biomaterials, 29(8), pp.970~983 (2008)
- Ogawa T, "Different bone integration profiles of turned and acid-etched implants associated with modulated expression of extracellular matrix genes", Int J Oral Maxillofac Implants, 18(2), pp.200~210 (2003)
- Wennerberg A, "On implant surfaces : a review of current knowledge and opinions", Int J Oral Maxillofac Implants, 25(1), pp.63~74 (2010)
- Kronström M, "Early implant failures in patients treated with Brånemark System titanium dental implants : a retrospective study", Int J Oral Maxillofac Implants, 16(2), pp.201~207 (2001)
- Zarb GA, "Towards optimized treatment outcomes for dental implants", The journal of prosthetic dentistry, 80(6), pp.639~640 (1998)
- Berglundh T, "A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years", J Clin Periodontol, 29, pp.197~212 (2002)
- Palma-Carrió C, "Risk factors associated with early failure of dental implants. A literature review", Med Oral Patol Oral Cir Bucal, 16(4), pp.e514~e517 (2011)
- Baqain ZH, "Early dental implant failure : risk factors", Br J Oral Maxillofac Surg, 50(3), pp.239~243 (2012)
- Sverzut AT, "The influence of tobacco on early dental implant failure", J Oral Maxillofac Surg, 66(5), pp.1004~1009 (2008)
- Friberg B, "Early failures in 4, 641 consecutively placed Brånemark dental implants : a study from stage 1 surgery to the connection of completed prostheses", Int J Oral Maxillofac Implants, 6(2), pp.142~146 (1991)
- Olate S, "Influence of diameter and length of implant on early dental implant failure", J Oral Maxillofac Surg, 68(2), pp.414~419 (2010)
- Alsaadi G, "Impact of local and systemic factors on the incidence of failures up to abutment connection with modified surface oral implants", J Clin Periodontol, 35(1), pp.51~57 (2008)
- Alsaadi G, "Impact of local and systemic factors on the incidence of oral implant failures, up to abutment connection", J Clin Periodontol, 34(7), pp.610~617 (2007)
- Leite MF, "Osseointegrated implant failure associated with MMP-1 promotor polymorphisms(-1607 and-519)", Int J Oral Maxillofac Implants, 23(4), pp.653~658 (2008)
- Noguerol B, "Prognostic capacity of Periotest® : retrospective study of a large sample", Clin Oral Implants Res, 17(4), pp.459~464 (2006)
- Van Steenberghe D, "The relative impact of local and endogenous patient-related factors on implant failure up to the abutment stage", Clin Oral Implants Res, 13(6), pp.617~622 (2002)
- Buser D, "Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs", J Biomed Mater Res, 25(7), pp.889~902 (1991)
- Abrahamsson I, "Early bone formation adjacent to rough and turned endosseous implant surfaces : an experimental study in the dog", Clin Oral Implants Res, 15(4), pp.381~392 (2004)
- Albertini M, "Advances in surfaces and osseointegration in implantology. Biomimetic surfaces", Med Oral Patol Oral Cir Bucal, 20(3), pp.e316~e25 (2015)
- Yuan K, "Comparison of osseointegration on various implant surfaces after bacterial contamination and cleaning : a rabbit study", Int J Oral Maxillofac Implants, 29(1), pp.32~40 (2014)
- Morra M, "Adherent endotoxin on dental implant surfaces : a reappraisal", J Oral Implantol, 41(1), pp.10~16 (2015)
- Bi Y, "Adherent endotoxin on orthopedic wear particles stimulates cytokine production and osteoclast differentiation", J Bone Miner Res, 16(11), pp.2082~2091 (2001)
- Greenfield EM, "Does endotoxin contribute to aseptic loosening of orthopedic implants?", J Biomed Mater Res B Appl Biomater, 72(1), pp.179~185 (2005)
- Bonsignore LA, "Surface contaminants inhibit osseointegration in a novel murine model", Bone, 49(5), pp.923~930 (2011)
- Bonsignore LA, "Machine oil inhibits the osseointegration of orthopaedic implants by impairing osteoblast attachment and spreading", J Orthop Res, 33(7), pp.979~987 (2015)