Effect of repeated use of an implant handpiece on an output torque: An in-vitro study

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose. This study aimed to evaluate the effect of repeated use of an implant handpiece under an implant placement torque (35 Ncm) and overloading torque condition (50 Ncm) on an output torque. Materials and Methods. Two types of implant handpiece systems (Surgicpro/X-DSG20L [NSK, Kanuma, Japan] and SIP20/CRB46LN [SAESHIN, Daegu, South Korea]) were used. The output torque was measured using a digital torque gauge. The height and angle (x, y, and z axes) of the digital torque gauge and implant handpiece were adjusted through a jig for passive connection. The experiment was conducted under the setting torque value of 35 Ncm (implant placement torque) and 50 Ncm (overloading torque condition) and 30 times per set; a total of 5 sets were performed (N = 150). For statistical analysis, the difference between the groups was analyzed using the Mann–Whitney U test and the Friedman test was used to confirm the change in output torque (α=.05). Results. NSK and SAESHIN implant handpieces showed significant differences in output torque results at the setting torques of 35 Ncm and 50 Ncm (P <.001). The type of implant handpiece and repeated use influenced the output torque (P <.001). Conclusion. There may be a difference between the setting torque and actual output torque due to repeated use, and the implant handpiece should be managed and repaired during long-term use. In addition, for successful implant results in dental clinics, the output torque of the implant handpiece system should be checked before implant placement.

Abstract

Purpose. This study aimed to evaluate the effect of repeated use of an implant handpiece under an implant placement torque (35 Ncm) and overloading torque condition (50 Ncm) on an output torque. Materials and Methods. Two types of implant handpiece systems (Surgicpro/X-DSG20L [NSK, Kanuma, Japan] and SIP20/CRB46LN [SAESHIN, Daegu, South Korea]) were used. The output torque was measured using a digital torque gauge. The height and angle (x, y, and z axes) of the digital torque gauge and implant handpiece were adjusted through a jig for passive connection. The experiment was conducted under the setting torque value of 35 Ncm (implant placement torque) and 50 Ncm (overloading torque condition) and 30 times per set; a total of 5 sets were performed (N = 150). For statistical analysis, the difference between the groups was analyzed using the Mann–Whitney U test and the Friedman test was used to confirm the change in output torque (α=.05). Results. NSK and SAESHIN implant handpieces showed significant differences in output torque results at the setting torques of 35 Ncm and 50 Ncm (P <.001). The type of implant handpiece and repeated use influenced the output torque (P <.001). Conclusion. There may be a difference between the setting torque and actual output torque due to repeated use, and the implant handpiece should be managed and repaired during long-term use. In addition, for successful implant results in dental clinics, the output torque of the implant handpiece system should be checked before implant placement.

참고문헌 (21)

  1. Neugebauer J, "Comparison of torque measurements and clinical handling of various surgical motors", Int J Oral Maxillofac Implants, 24, pp.469~476 (2009)
  2. Roberts HW, "Oral surgical handpiece use time parameters", J Oral Maxillofac Surg, 63, pp.957~960 (2005)
  3. Golob Deeb J, "Exploring training dental implant placement using computer-guided implant navigation system for predoctoral students: a pilot study", Eur J Dent Educ, 23, pp.415~423 (2019)
  4. Eriksson RA, "Temperatures during drilling for the placement of implants using the osseointegration technique", J Oral Maxillofac Surg, 44, pp.4~7 (1986)
  5. Augustin G, "Cortical bone drilling and thermal osteonecrosis", Clin Biomech(Bristol, Avon), 27, pp.313~325 (2012)
  6. Lee J, "Parameters affecting mechanical and thermal responses in bone drilling : a review", J Biomech, 71, pp.4~21 (2018)
  7. Cavazos E, "Preventing loosening of implant abutment screws", J Prosthet Dent, 75, pp.566~569 (1996)
  8. Jaarda MJ, "Effect of preload torque on the ultimate tensile strength of implant prosthetic retaining screws", Implant Dent, 3, pp.17~21 (1994)
  9. 주용훈, "임상에서 사용하고 있는 임플란트 토크조절기의 정확도와 적용에 관한 사용실태", 대한치과보철학회지, 49(03), pp.197~205 (2011), 대한치과보철학회[DOI]
  10. Lee DH, "The overuse of the implant motor : effect on the output torque in overloading condition", Clin Implant Dent Relat Res, 17, pp.435~441 (2015)
  11. Aydemir CA, "Accuracy of dental implant placement via dynamic navigation or the freehand method : a split-mouth randomized controlled clinical trial", Clin Oral Implants Res, 31, pp.255~263 (2020)
  12. Chen CK, "Accuracy of implant placement with a navigation system, a laboratory guide, and freehand drilling", Int J Oral Maxillofac Implants, 33, pp.1213~1218 (2018)
  13. Kastala VH, "Comparative evaluation of implant stability in two different implant systems at baseline and 3-4 months intervals using RFA device(OSSTELL ISQ)", Indian J Dent Res, 30, pp.678~686 (2019)
  14. Yared G, "Accuracy of the Nouvag torque control motor for nickel-titanium rotary instruments", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 97, pp.499~501 (2004)
  15. Fugito Junior K, "Comparative study on the cutting effectiveness and heat generation of rotary instruments versus piezoelectric surgery tips using scanning electron microscopy and thermal analysis", Int J Oral Maxillofac Implants, 33, pp.345~350 (2018)
  16. Tur D, "Thermal effects of various drill materials during implant site preparation-Ceramic vs. stainless steel drills: a comparative in vitro study in a standardised bovine bone model", Clin Oral Implants Res, 32, pp.154~166 (2021)
  17. Sannino G, "Thermal changes during guided flapless implant site preparation : A comparative study", Int J Oral Maxillofac Implants, 33, pp.671~677 (2018)
  18. Strietzel FP, "Peri-implant alveolar bone loss with respect to bone quality after use of the osteotome technique : results of a retrospective study", Clin Oral Implants Res, 13, pp.508~513 (2002)
  19. Eriksson AR, "Temperature threshold levels for heat-induced bone tissue injury : a vital-microscopic study in the rabbit", J Prosthet Dent, 50, pp.101~107 (1983)
  20. Trisi P, "High versus low implant insertion torque: a histologic, histomorphometric, and biomechanical study in the sheep mandible", Int J Oral Maxillofac Implants, 26, pp.837~849 (2011)
  21. Khayat PG, "Clinical outcome of dental implants placed with high insertion torques(up to 176 Ncm)", Clin Implant Dent Relat Res, 15, pp.227~233 (2013)

관련 논문AI추천

이 간행물의 다른 논문 (6건)