A Study on Dose Evaluation in DR System depending on Grid Use

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

The purpose of this study was to suggest strategies for the appropriateness of griduse and reduction of exposure dose by conducting a survey on the use of a digital radiography(DR) system in 30 general hospitals located in the capital area. With the goal of using its resultsas basic data in the future, this study measured the change in dose depending on use or no use ofa grid. The study method was to conduct a survey on the possession of DR equipment and griduse for examination of the extremities among 30 general hospitals in the capital area. In regardto exposure dose, acryl phantom was used to measure the change in dose depending on use or nouse of a grid. The results of the survey questionnaire showed that a grid was used for examinationin 97 out of 135 total pieces of equipment, while a grid was not used in the remaining 38 piecesof equipment. With respect to dose evaluation, the dose for each body part depending on use orno use of a grid was measured at 81.50±9.01 μGy and 129.80±0.26 μGy in the acryl phantomthickness of 2.54 cm+1.0 mmAl, 67.08±0.22 μGy and 110.94±34.66 μGy in the thickness of 5.08cm+1.0 mmAl, and 297.99±0.63 μGy and 567.39±1.58 μGy in the thickness of 7.62 cm+2.0mmAl. In conclusion, there was a difference of about two-fold or more in the dose depending onuse or no use of a grid.

Abstract

The purpose of this study was to suggest strategies for the appropriateness of griduse and reduction of exposure dose by conducting a survey on the use of a digital radiography(DR) system in 30 general hospitals located in the capital area. With the goal of using its resultsas basic data in the future, this study measured the change in dose depending on use or no use ofa grid. The study method was to conduct a survey on the possession of DR equipment and griduse for examination of the extremities among 30 general hospitals in the capital area. In regardto exposure dose, acryl phantom was used to measure the change in dose depending on use or nouse of a grid. The results of the survey questionnaire showed that a grid was used for examinationin 97 out of 135 total pieces of equipment, while a grid was not used in the remaining 38 piecesof equipment. With respect to dose evaluation, the dose for each body part depending on use orno use of a grid was measured at 81.50±9.01 μGy and 129.80±0.26 μGy in the acryl phantomthickness of 2.54 cm+1.0 mmAl, 67.08±0.22 μGy and 110.94±34.66 μGy in the thickness of 5.08cm+1.0 mmAl, and 297.99±0.63 μGy and 567.39±1.58 μGy in the thickness of 7.62 cm+2.0mmAl. In conclusion, there was a difference of about two-fold or more in the dose depending onuse or no use of a grid.

참고문헌 (14)

  1. Axelsson B, "A comparison of analogue and digital techniques in upper gastrointestinal examinations : absorbed dose and diagnostic quality of the images", Eur. Radiol, 10, pp.1351~1354 (2000)
  2. Technical Electronic Product Radiation Safety Standards Committee, "FDA", Food and Drug Administration, ~
  3. 홍성일, "SNR and PSNR measurements and analysis of median filtering for the removal of impulse noise from CR imaging", International Journal of Contents, 5(4), pp.7~12 (2009), 한국콘텐츠학회
  4. IAEA, "IAEA Safety series No. 115", International Atomic Energy Agency, ~ (1996)
  5. Managing Patient Dose in Digital. International Commission on Radiological Protection publication 93, "ICRP", ~ (2003)
  6. Korner M, "Advances in digital radiography : physical principles and system overview", Radiographics, 27(3), pp.675~686 (2007)
  7. 이인자, "FPD System에서 상․하지 촬영 시 격자에 따른 환자 선량 및 화질 평가", 방사선기술과학, 33(4), pp.341~348 (2010), 대한방사선과학회
  8. 이종웅, "Evaluation of the Response of the Modulation Transfer Function to a Computed Radiography Photostimulable Phosphor Imaging Plate for Various Numbers of X-ray Exposures", Journal of the Korean Physical Society, 58(2), pp.326~333 (2011), 한국물리학회
  9. Pascoal A, "Chest radiography - A comparison of image quality and effective dose using four digital systems", Radiat. Prot. Dosimetry, 114(1-3), pp.273~277 (2005)
  10. Rapp-Bernhardt U, "Flat-Panel X-ray Detector Based on Amorphous Silicon Versus Asymmetric Screen-Film System : Phantom Study of Dose Reduction and Depiction of Simulated Findings", Radiology, 227(2), pp.484~492 (2003)
  11. Samei E, "Comparative scatter and dose performance of slot-scan and full-field digital chest radiography systems", Radiology, 235(3), pp.940~949 (2005)
  12. Strotzer M, "Clinical application of a flat-panel X-ray detector based on amorphous silicon technology : image quality and potential for radiation dose reduction in skeletal radiography", Am. J. Roentgenol, 171(1), pp.23~27 (1998)
  13. Strotzer M, "Simulated Bone Erosions in a Hand Phantom : Detection with Conventional Screen-Film Technology versus Cesium Iodide-Amorphous Silicon Flat-Panel Detector", Radiology, 215(2), pp.512~515 (2000)
  14. Health effects and protective measures, "WHO", World Health Organization, ~ (2011)

관련 논문AI추천

이 간행물의 다른 논문 (8건)