DR 시스템에서 모드 변화에 따른 구리필터의 유용성 평가

Evaluation for the Usefulness of Copper Filters according to Mode Change in Digital Radiography System

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류방사선과학

초록

This study confirmed the usefulness of the copper filter according to the mode change by comparing and analyzing the energy change according to the application of the copper filter and the change in effective dose and image quality according to the distance to the subject in the DR(Digital Radiography) system. The average energy increased when the copper filter was applied and the reduction rate by 50% of mAs was increased as the thickness of the copper filter increased according to the application of the 10 kVp rule in AEC mode. The effective dose decreased as the thickness increased when the copper filter was applied in AEC(Automatic Exposure Control) mode and manual mode according to the application of the 10 kVp rule, and the decrease rate decreased with increasing 10 kVp increments. As a result of analyzing the dicom images for AEC mode and manual mode with Image J. the PSNR(Peak Signal to Noise Ratio) values were approximate values of less than 30 dB for each mode and for each copper filter thickness. When the copper filter was applied, the average energy increased, so when the 10 kVp rule was applied, the mAs for each mode could be reduced, and the effective dose could also be reduced. However, as the distance and tube voltage increased, the reduction rate of mAs decreased, and the quality of the image was found to decrease when the copper filter was applied, but there was no difference in quality of the image when the copper filter thickness increased.

Abstract

This study confirmed the usefulness of the copper filter according to the mode change by comparing and analyzing the energy change according to the application of the copper filter and the change in effective dose and image quality according to the distance to the subject in the DR(Digital Radiography) system. The average energy increased when the copper filter was applied and the reduction rate by 50% of mAs was increased as the thickness of the copper filter increased according to the application of the 10 kVp rule in AEC mode. The effective dose decreased as the thickness increased when the copper filter was applied in AEC(Automatic Exposure Control) mode and manual mode according to the application of the 10 kVp rule, and the decrease rate decreased with increasing 10 kVp increments. As a result of analyzing the dicom images for AEC mode and manual mode with Image J. the PSNR(Peak Signal to Noise Ratio) values were approximate values of less than 30 dB for each mode and for each copper filter thickness. When the copper filter was applied, the average energy increased, so when the 10 kVp rule was applied, the mAs for each mode could be reduced, and the effective dose could also be reduced. However, as the distance and tube voltage increased, the reduction rate of mAs decreased, and the quality of the image was found to decrease when the copper filter was applied, but there was no difference in quality of the image when the copper filter thickness increased.

참고문헌 (15)

  1. KFDA, "Measurement guideline of patient dose", ~ (2007)
  2. A Study on building the management system and methods of patient radiation exposure dose, "Kim JM", National Evidence-based Healthcare Collaborating Agency, ~ (2014)
  3. 신성규, "디지털 방사선장비에서 자동노출제어 사용 시 환자피폭선량 감소 방안", 방사선기술과학, 36(2), pp.111~122 (2013), 대한방사선과학회
  4. 신수인, "디지털 흉부 촬영에서 구리필터사용에 따른 환자 표면선량 감소효과에 관한 연구", 방사선기술과학, 31(3), pp.223~228 (2008), 대한방사선과학회
  5. 유민정, "방사선 선량관리 서비스의 서비스품질과 고객만족과의 관계에 관한 실증연구", 예술인문사회 융합 멀티미디어 논문지, 8(5), pp.513~521 (2018), 사단법인 인문사회과학기술융합학회[DOI]
  6. 조우일, "유방촬영용장치 부가필터에 따른 선량변화 및 화질개선", 방사선방어학회지, 38(2), pp.78~90 (2013), 테스트학회
  7. 김상현, "디지털 방사선장치에서 구리 부가필터의 유용성 평가에 관한 융복합 연구", 디지털융복합연구, 13(9), pp.351~359 (2015), 한국디지털정책학회[DOI]
  8. 신성규, "골반촬영 시 내장된 필터를 이용한 환자선량 감소", 한국콘텐츠학회 논문지, 12(8), pp.233~239 (2012), 한국콘텐츠학회[DOI]
  9. 복근성, "부가필터를 적용한 디지털 흉부단층합성검사에서 환자 체형에 따른 화질 평가와 선량감소 효과", 한국방사선학회논문지, 12(1), pp.23~30 (2018), 한국방사선학회[DOI]
  10. Kim JJ, "Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography", Korean Journal of Digital Imaging in Medicine, 14(2), pp.23~31 (2012)
  11. Claudia R, "Image quality and dose analysis for a PA chest X-ray: Comparison between AEC mode acquisition and manual mode using the 10 kVp 'rule'", Radiography, 20(4), pp.339~345 (2014)
  12. Luís L, "10 kVp rule–an anthropomorphic pelvis phantom imaging study using a CR system : Impact on image quality and effective dose using AEC and manual mode", Radiography, 20(3), pp.333~338 (2014)
  13. 김교태, "진단영상 시스템에서 선량크리프 현상의 최소화를 위한 고감도 AEC 센서에 관한 연구", 한국방사선학회논문지, 10(5), pp.321~325 (2016), 한국방사선학회[DOI]
  14. 이광재, "디지털 방사선촬영 환경에서 선량의 최적화 및 영상품질에 대한 연구", 전자공학회논문지, 50(2), pp.203~209 (2013), 대한전자공학회
  15. Shepard S, "An exposure indicator for digital radiography : AAPM Task Group 116(Executive Summary)", Medical Physics, 36(7), pp.2898~2914 (2009)

관련 논문AI추천

이 간행물의 다른 논문 (7건)