뇌졸중 환자에서 스마트폰 어플리케이션을 이용한 능동적 머리목관절 가동범위 측정에 관한 측정자간 신뢰도 연구
The Inter-Rater Reliability of Measurements of Active Craniocervical Range of Motion With Smartphone in Patients With Stroke
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Background: Numerous studies have used smartphone applications to measure the range of motion in different joints. In addition, studies measuring the active range of motion (AROM) of the craniocervical joint have revealed high reliability. However, the subjects in these studies were all healthy subjects. No study has yet been conducted to measure the inter-rater reliability for the AROM of the craniocervical joint in stroke patients. Objects: The purpose of this study was to investigate the inter-rater reliability of the AROM of the craniocervical joint using a smartphone. Methods: The participants included 21 subjects who had strokes (17 males and 4 females). Two raters evaluated six types of craniocervical AROM, including flexion, extension, lateral flexion to the hemiplegic side, lateral flexion to the non-hemiplegic side, rotation to the hemiplegic side, and rotation to the non-hemiplegic side, using a goniometer and a smartphone to investigate inter-rater reliability. The inter-rater reliability was analyzed by intraclass correlation coefficients (ICC). Results: The inter-rater reliability of the smartphone was good for extension, lateral flexion to the hemiplegic side, lateral flexion to the non-hemiplegic side, and rotation to the hemiplegic side [ICC(2,k)=.86∼.88] and excellent for flexion [ICC(2,k)=.95]. The inter-rater reliability for rotation to the non-hemiplegic side was moderate [ICC(2,k)=.72]. Conclusion: These results suggest that the smartphone offers high inter-rater reliability for measurements of the craniocervical AROM in patients with stroke.
Abstract
Background: Numerous studies have used smartphone applications to measure the range of motion in different joints. In addition, studies measuring the active range of motion (AROM) of the craniocervical joint have revealed high reliability. However, the subjects in these studies were all healthy subjects. No study has yet been conducted to measure the inter-rater reliability for the AROM of the craniocervical joint in stroke patients. Objects: The purpose of this study was to investigate the inter-rater reliability of the AROM of the craniocervical joint using a smartphone. Methods: The participants included 21 subjects who had strokes (17 males and 4 females). Two raters evaluated six types of craniocervical AROM, including flexion, extension, lateral flexion to the hemiplegic side, lateral flexion to the non-hemiplegic side, rotation to the hemiplegic side, and rotation to the non-hemiplegic side, using a goniometer and a smartphone to investigate inter-rater reliability. The inter-rater reliability was analyzed by intraclass correlation coefficients (ICC). Results: The inter-rater reliability of the smartphone was good for extension, lateral flexion to the hemiplegic side, lateral flexion to the non-hemiplegic side, and rotation to the hemiplegic side [ICC(2,k)=.86∼.88] and excellent for flexion [ICC(2,k)=.95]. The inter-rater reliability for rotation to the non-hemiplegic side was moderate [ICC(2,k)=.72]. Conclusion: These results suggest that the smartphone offers high inter-rater reliability for measurements of the craniocervical AROM in patients with stroke.
참고문헌 (34)
- Kamal Narayan Arya, "Movement therapy induced neural reorganization and motor recovery in stroke: A review", Journal of Bodywork and Movement Therapies, 15(4), pp.528~537 (2011), Elsevier BV[DOI]
- Greg Atkinson, "Statistical Methods For Assessing Measurement Error (Reliability) in Variables Relevant to Sports Medicine", Sports Medicine, 26(4), pp.217~238 (1998), Springer Science and Business Media LLC[DOI]
- Behnam Behnoush, "Smartphone and Universal Goniometer for Measurement of Elbow Joint Motions: A Comparative Study", Asian Journal of Sports Medicine, 7(2), pp.e30668~ (2016), Kowsar Medical Institute[DOI]
- Bennett SE, "Active range of motion utilized in the cervical spine to perform daily functional tasks", J Spinal Disord Tech, 15(4), pp.307~311 (2002)
- P. Bracco, "Effects of different jaw relations on postural stability in human subjects", Neuroscience Letters, 356(3), pp.228~230 (2004), Elsevier BV[DOI]
- Karen Chen, "Chronic post-stroke fatigue: It may no longer be about the stroke itself", Clinical Neurology and Neurosurgery, 174, pp.192~197 (2018), Elsevier BV[DOI]
- M. C. Cramp, "Low intensity strength training for ambulatory stroke patients", Disability and Rehabilitation, 28(13-14), pp.883~889 (2009), Informa UK Limited[DOI]
- Gajdosik RL, "Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity", Phys Ther, 67(12), pp.1867~1872 (1987)
- Jing Gao, "Quantitative Ultrasound Imaging to Assess the Biceps Brachii Muscle in Chronic Post-Stroke Spasticity: Preliminary Observation", Ultrasound in Medicine & Biology, 44(9), pp.1931~1940 (2018), Elsevier BV[DOI]
- Jaime Guzman, "A New Conceptual Model of Neck Pain", Journal of Manipulative and Physiological Therapeutics, 32(2), pp.S17~S28 (2009), Elsevier BV[DOI]
- Jan Kottner, "Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed", International Journal of Nursing Studies, 48(6), pp.661~671 (2011), Elsevier BV[DOI]
- Haw-Chang H Lan, "The shift of segmental contribution ratio in patients with herniated disc during cervical lateral bending", BMC Musculoskeletal Disorders, 15(1), pp.273~ (2014), Springer Science and Business Media LLC[DOI]
- Duck-Won Oh, "Effect of Stomatognathic Alignment Exercise on Temporomandibular Joint Function and Swallowing Function of Stroke Patients with Limited Mouth Opening", Journal of Physical Therapy Science, 25(10), pp.1325~1329 (2013), Society of Physical Therapy Science[DOI]
- O'Sullivan SB, "Physical Rehabilitation", pp.138~ (2013), F. A. Davis Company
- Simon J. Otter, "The reliability of a smartphone goniometer application compared with a traditional goniometer for measuring first metatarsophalangeal joint dorsiflexion", Journal of Foot and Ankle Research, 8(1), pp.30~ (2015), Springer Science and Business Media LLC[DOI]
- Page P, "Sensorimotor training : A"global"approach for balance training", J Bodyw Mov Ther, 10(1), pp.77~84 (2006)
- Page P, "Assessment and Treatment of Muscle Imbalance: The Janda Approach", pp.175~ (2010), Human Kinetics
- Park JH, "Standardization of Korean version of the mini-mental state examination (MMSE-K) for use in the elderly. Part Ⅱ. Diagnostic validity", J Korean Neuropsychiatr Assoc, 28(3), pp.508~513 (1989)
- Portney LG, "Foundations of Clinical Research: Applications to practice", pp.594~595 (2009), Prentice Hall Inc.
- Mohammad Reza Pourahmadi, "A new iPhone application for measuring active craniocervical range of motion in patients with non-specific neck pain: a reliability and validity study", The Spine Journal, 18(3), pp.447~457 (2018), Elsevier BV[DOI]
- Mohammad Reza Pourahmadi, "Reliability and concurrent validity of a new iPhone® goniometric application for measuring active wrist range of motion: a cross-sectional study in asymptomatic subjects", Journal of Anatomy, 230(3), pp.484~495 (2017), Wiley[DOI]
- Angela Schlager, "Inter- and intra-rater reliability for measurement of range of motion in joints included in three hypermobility assessment methods", BMC Musculoskeletal Disorders, 19(1), pp.376~ (2018), Springer Science and Business Media LLC[DOI]
- Arlene A. Schmid, "Yoga leads to multiple physical improvements after stroke, a pilot study", Complementary Therapies in Medicine, 22(6), pp.994~1000 (2014), Elsevier BV[DOI]
- Seung Han Shin, "Within-day reliability of shoulder range of motion measurement with a smartphone", Manual Therapy, 17(4), pp.298~304 (2012), Elsevier BV[DOI]
- Martijn S. Stenneberg, "Concurrent validity and interrater reliability of a new smartphone application to assess 3D active cervical range of motion in patients with neck pain", Musculoskeletal Science and Practice, 34, pp.59~65 (2018), Elsevier BV[DOI]
- Martijn S. Stenneberg, "To What Degree Does Active Cervical Range of Motion Differ Between Patients With Neck Pain, Patients With Whiplash, and Those Without Neck Pain? A Systematic Review and Meta-Analysis", Archives of Physical Medicine and Rehabilitation, 98(7), pp.1407~1434 (2017), Elsevier BV[DOI]
- Streiner DL, "Health Measurement Scales: A practical guide to their development and use", pp.171~ (2015), Oxford University Press
- Peter S. Theobald, "Do inertial sensors represent a viable method to reliably measure cervical spine range of motion?", Manual Therapy, 17(1), pp.92~96 (2012), Elsevier BV[DOI]
- Aurore Thibaut, "Spasticity after stroke: Physiology, assessment and treatment", Brain Injury, 27(10), pp.1093~1105 (2013), Informa UK Limited[DOI]
- Yannick Tousignant-Laflamme, "Reliability and criterion validity of two applications of the iPhone™ to measure cervical range of motion in healthy participants", Journal of NeuroEngineering and Rehabilitation, 10(1), pp.69~ (2013), Springer Science and Business Media LLC[DOI]
- Tousignant M, "Criterion validity study of the cervical range of motion(CROM)device for rotational range of motion on healthy adults", J Orthop Sports Phys Ther, 36(4), pp.242~248 (2006)
- de Vet HC, "Measurement in Medicine: A practical guide", pp.124~ (2011), Cambridge University Press
- Tracy L. Wallwork, "Intrarater and Interrater Reliability of Assessment of Lumbar Multifidus Muscle Thickness Using Rehabilitative Ultrasound Imaging", Journal of Orthopaedic & Sports Physical Therapy, 37(10), pp.608~612 (2007), Journal of Orthopaedic & Sports Physical Therapy (JOSPT)[DOI]
- Mark A. Williams, "A Systematic Review of Reliability and Validity Studies of Methods for Measuring Active andPassive Cervical Range of Motion", Journal of Manipulative and Physiological Therapeutics, 33(2), pp.138~155 (2010), Elsevier BV[DOI]