뇌졸중 환자의 수동적 어깨 관절 가동범위 측정에 관한 스마트폰과 측각기의 측정자내, 측정자간 신뢰도 연구

Intra- and Inter-Rater Reliability of Measuring Passive Range of Shoulder Motion With Smartphone and Goniometer in Patients With Stroke

2

조회

0

다운로드

16

인용

0

참고문헌

키워드

주제분류물리치료학

초록

The purpose of this study were to determine the intra-rater and inter-rater reliability of shoulder passive range of motion measurement using the “Clinometer + bubble level”, a smartphone application and to compare with the intra-rater and inter-rater reliability of measurement using a goniometer. Twenty six patients with stroke were recruited for this study. Two raters measured the passive range of motion of four types of shoulder movements (forward flexion; FF, abduction; ABD, external rotation at 90° abduction; ER90 and internal rotation at 90° abduction; IR90) using a goniometer and a smartphone to determine within-day inter-rater reliability. A retest session was performed thirty minutes later to determine within-day intra-rater reliability. The reliability was assessed using intraclass correlation coefficients (ICC) and the standard error of measurement (SEM). The ICC (2,1) for the inter-rater reliabilities of the goniometer and smartphone were good in FF and ABD [ICC (2,1)=.75∼.87] and excellent in ER90 [ICC (2,1)=.90∼.95]. The intra-rater reliabilities for the goniometer and smartphone were good or more than good, with an ICC (3,1) value >.75, the exception was IR90 measured by rater 2 on the smartphone. These results suggest that smartphone could be used as an alternative method tool for measurement of passive shoulder range of motion in patients with stroke.

Abstract

The purpose of this study were to determine the intra-rater and inter-rater reliability of shoulder passive range of motion measurement using the “Clinometer + bubble level”, a smartphone application and to compare with the intra-rater and inter-rater reliability of measurement using a goniometer. Twenty six patients with stroke were recruited for this study. Two raters measured the passive range of motion of four types of shoulder movements (forward flexion; FF, abduction; ABD, external rotation at 90° abduction; ER90 and internal rotation at 90° abduction; IR90) using a goniometer and a smartphone to determine within-day inter-rater reliability. A retest session was performed thirty minutes later to determine within-day intra-rater reliability. The reliability was assessed using intraclass correlation coefficients (ICC) and the standard error of measurement (SEM). The ICC (2,1) for the inter-rater reliabilities of the goniometer and smartphone were good in FF and ABD [ICC (2,1)=.75∼.87] and excellent in ER90 [ICC (2,1)=.90∼.95]. The intra-rater reliabilities for the goniometer and smartphone were good or more than good, with an ICC (3,1) value >.75, the exception was IR90 measured by rater 2 on the smartphone. These results suggest that smartphone could be used as an alternative method tool for measurement of passive shoulder range of motion in patients with stroke.

참고문헌 (52)

  1. Andrews AW, "Decreased shoulder range of motion on paretic side after stroke", Phys Ther, 69(9), pp.768~772 (1989)
  2. Boon AJ, "Manual scapular stabilization : Its effect on shoulder rotational range of motion", Arch Phys Med Rehabil, 81(7), pp.978~983 (2000)
  3. Cadet ER, "Evaluation of glenohumeral instability", Orthop Clin North Am, 41(3), pp.287~295 (2010)
  4. Cadogan A, "Reliability of a new hand-held dynamometer in measuring shoulder range of motion and strength", Man Ther, 16(1), pp.97~101 (2011)
  5. Clarkson HM., "Musculoskeletal Assessment: Joint range of motion and manual muscle strength", pp.108~120 (2000), Lippincott Williams &Wilkins
  6. Conroy BE, "Hospital-based stroke rehabilitation in the united states", Top Stroke Rehabil, 16(1), pp.34~43 (2009)
  7. de Jong LD, "Repeated measurements of arm joint passive range of motion after stroke : Interobserver reliability and sources of variation", Phys Ther, 92(8), pp.1027~1035 (2012)
  8. de Jong LD, "Arm motor control as predictor for hypertonia after stroke : A prospective cohort study", Arch Phys Med Rehabil, 92(9), pp.1411~1417 (2011)
  9. de Jong LD, "The hemiplegic arm : Interrater reliability and concurrent validity of passive range of motion measurements", Disabil Rehabil, 29(18), pp.1442~1448 (2007)
  10. de Winter AF, "Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer", BMC Musculoskelet Disord, 5, pp.18~ (2004)
  11. Dijkerman HC, "Johnston M, et al. Does motor imagery training improve hand function in chronic stroke patients? A pilot study", Clin Rehabil, 18(5), pp.538~549 (2004)
  12. Ellenbecker TS, "Glenohumeral joint internal and external rotation range of motion in elite junior tennis players", J Orthop Sports Phys Ther, 24(6), pp.336~341 (1996)
  13. Ferriero G, "Reliability of a new application for smartphones(DrGoniometer)for elbow angle measurement", PM R, 3(12), pp.1153~1154 (2011)
  14. Ferriero G, "Reliability of a smartphone-based goniometer for knee joint goniometry", Int J Rehabil Res, 36(2), pp.146~151 (2013)
  15. Gajdosik RL, "Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity", Phys Ther, 67(12), pp.1867~1872 (1987)
  16. Green S, "A standardized protocol for measurement of range of movement of the shoulder using the plurimeter-v inclinometer and assessment of its intrarater and interrater reliability", Arthritis Care Res, 11(1), pp.43~52 (1998)
  17. 한영석, "고령자의 스마트폰 사용성 향상을 위한 연구", 한국전자거래학회지, 17(1), pp.39~52 (2012), 한국전자거래학회
  18. Hardwick DD, "Scapular and humeral movement patterns of people with stroke during range of motion exercises", J Neurol Phys Ther, 35(1), pp.18~25 (2011)
  19. Hayes K, "Reliability of five methods for assessing shoulder range of motion", Aust J Physiother, 47(4), pp.289~294 (2001)
  20. Hébert LJ, "Scapular behavior in shoulder impingement syndrome", Arch Phys Med Rehabil, 83(1), pp.60~69 (2002)
  21. Hoving JL, "How reliably do rheumatologists measure shoulder movement?", Ann Rheum Dis, 61(7), pp.612~616 (2002)
  22. Howard G, "Decline in us stroke mortality : An analysis of temporal patterns by sex, race, and geographic region", Stroke, 32(10), pp.2213~2220 (2001)
  23. Jacquot F, "Measuring the cobb angle with the iphone in kyphoses: A reliability study", Int Orthop, 36(8), pp.1655~1660 (2012)
  24. Juul-Kristensen B, "Test-retest reliability of joint position and kinesthetic sense in the elbow of healthy subjects", Physiother Theory Pract, 24(1), pp.65~72 (2008)
  25. Jette DU, "Physical therapy interventions for patients with stroke in inpatient rehabilitation facilities", Phys Ther, 85(3), pp.238~248 (2005)
  26. Kisner C, "Therapeutic Exercise:Foundations and techniques", pp.34~38 (2002), Davis Co.
  27. Kolber MJ, "Reliability and minimal detectable change of inclinometric shoulder mobility measurements", Physiother Theory Pract, 25(8), pp.572~581 (2009)
  28. Kolber MJ, "The reliability and minimal detectable change of shoulder mobility measurements using a digital inclinometer", Physiother Theory Pract, 27(2), pp.176~184 (2011)
  29. "Wired and wireless subscribers statistics" (2012)[URL]
  30. Lewis JS, "Intraobserver reliability of angular and linear measurements of scapular position in subjects with and without symptoms", Arch Phys Med Rehabil, 89(9), pp.1795~1802 (2008)
  31. Logan LR, "Rehabilitation techniques to maximize spasticity management", Top Stroke Rehabil, 18(3), pp.203~211 (2011)
  32. McConnell J, "Passive and dynamic shoulder rotation range in uninjured and previously injured overhead throwing athletes and the effect of shoulder taping", PM R, 4(2), pp.111~116 (2012)
  33. Mottram SL, "Dynamic stability of the scapula", Man Ther, 2(3), pp.123~131 (1997)
  34. Muehlbauer T, "Intra and intersession reliability of balance measures during one-leg standing in young adults", J Strength Cond Res, 25(8), pp.2228~2234 (2011)
  35. Muir SW, "Evaluating change in clinical status : Reliability and measures of agreement for the assessment of glenohumeral range of motion", N Am J Sports Phys Ther, 5(3), pp.98~110 (2010)
  36. Mullaney MJ, "Reliability of shoulder range of motion comparing a goniometer to a digital level", Physiother Theory Pract, 26(5), pp.327~333 (2010)
  37. Norkin CC, "Measurement of Joint Motion:A guide to goniometry", pp.21~ (2009), Davis Co.
  38. Ockendon M, "Validation of a novel smartphone accelerometer-based knee goniometer", J Knee Surg, 25(4), pp.341~345 (2012)
  39. Ottenbacher KJ, "The results of clinical trials in stroke rehabilitation research", Arch Neurol, 50(1), pp.37~44 (1993)
  40. Park JH, "Standardization of Korean version of the mini-mental state examination (MMSE-K) for use in the elderly. Part Ⅱ. Diagnostic validity", J Korean Neuropsychiatr Assoc, 28(3), pp.508~513 (1989)
  41. 박규남, "Intra-Rater Test-Retest Reliability of Ely’s Test Using Smartphone in Patients With Lumbar Extension-Rotation Syndrome", 한국전문물리치료학회지, 19(4), pp.46~54 (2012), 한국전문물리치료학회
  42. Portney LG, "Foundations of Clinical Research: Applications to practice", pp.594~595 (2009), Prentice Hall Inc.
  43. Radomski MV, "Occupational Therapy for Physical Dysfunction", pp.94~ (2008), Williams & Wilkins
  44. Rajaratnam BS, "Predictability of simple clinical tests to identify shoulder pain after stroke", Arch Phys Med Rehabil, 88(8), pp.1016~1021 (2007)
  45. Riddle DL, "Goniometric reliability in a clinical setting : Shoulder measurements", Phys Ther, 67(5), pp.668~673 (1987)
  46. Sabari JS, "Goniometric assessment of shoulder range of motion : Comparison of testing in supine and sitting positions", Arch Phys Med Rehabil, 79(6), pp.647~651 (1998)
  47. Sackley C, "The prevalence of joint contractures, pressure sores, painful shoulder, other pain, falls, and depression in the year after a severely disabling stroke", Stroke, 39(12), pp.3329~3334 (2008)
  48. Shrout PE, "Intraclass correlations : Uses in assessing rater reliability", Psychol Bull, 86(2), pp.420~428 (1979)
  49. Shin SH, "Within-day reliability of shoulder range of motion measurement with a smartphone", Man Ther, 17(4), pp.298~304 (2012)
  50. "Causes of Death Statistics in 2010" (2011)[URL]
  51. Tveitå EK, "Range of shoulder motion in patients with adhesive capsulitis;Intra-tester reproducibility is acceptable for group comparisons", BMC Musculoskelet Disord, 9, pp.49~ (2008)
  52. Valentine RE, "Intraobserver reliability of 4physiologic movements of the shoulder in subjects with and without symptoms", Arch Phys Med Rehabil, 87(9), pp.1242~1249 (2006)

관련 논문AI추천

뇌졸중 환자에서 스마트폰 어플리케이션을 이용한 능동적 머리목관절 가동범위 측정에 관한 측정자간 신뢰도 연구문일영, 박규남, 박일우, 이충휘한국전문물리치료학회 · 한국전문물리치료학회지2019 · 제26권 제1호The Reliability and Validity of the Digital Goniometer and Smart Phone to Determine Trunk Active Range of Motion in Stroke Patients권오윤, 황의재, Park Hee-yong한국전문물리치료학회 · 한국전문물리치료학회지2022 · 제29권 제3호Determining the Reliability of a New Method for Measuring Joint Range of Motion Through a Randomized Controlled Trial안소영, Hanbit Ko, Jeong Oh Yoon, Jong Hyun Park, Kang Hee Cho, Sun Ung Cho대한재활의학회 · Annals of Rehabilitation Medicine2019 · 제43권 제6호어깨관절의 수동적 내회전 관절 가동범위의 측정 방법에 따른 신뢰도와 상완골두의 전방 활주 거리 비교김현숙, 이원휘, 정성대한국전문물리치료학회 · 한국전문물리치료학회지2010 · 제17권 제3호Reliability Study of Measuring Range of Motion Glenohumeral Joint Internal Rotation With Pressure Biofeedback Stabilization권오윤, 김수정, 전인철, 정성훈, 최규환, 하성민, 황의재한국전문물리치료학회 · 한국전문물리치료학회지2015 · 제22권 제4호만성 뇌졸중환자의 견관절 위치감각에 대한 수동운동과 능동운동의 효과 비교배은희, 오덕원특수교육재활과학연구소 · 특수교육재활과학연구2011 · 제50권 제2호

이 간행물의 다른 논문 (7건)