Validation of Joint Position Sense of Dorsi-Plantar Flexion of Ankle Measurements Using a Smartphone
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Objectives: This study evaluated and validated the reliability of smartphones as measuring equipment for the dorsi-plantar flexion of ankle joint position sense (JPS) ability. Methods: The subjects were 20 healthy young students in their 20s. We confirmed the concurrent validity by comparison with existing electrogoniometer data. The reliability of the smartphone was confirmed using the test-retest method. Results: In the case of dorsiflexion, there was no significant difference between the smartphone and electrogoniometer groups (p > 0.05). Regarding the correlation, it was significantly high (r = 0.65, p < 0.05), and ICC(3,1) was good (ICC(3,1) = 0.79). For the case of plantar flexion, there was no significant difference between the smartphone and electrogoniometer groups (p > 0.05), the correlation was significantly high (r = 0.69, p < 0.05), and the ICC(3,1) was very good (ICC(3,1) = 0.82). In the case of dorsiflexion, there was no significant difference between test and retest (p > 0.05), the correlation was intermediate (r = 0.59, p < 0.05), and the ICC(3,1) value was good (ICC(3,1) = 0.74). For plantar flexion, there was no significant difference between test and retest (p > 0.05), the correlation was significantly high (r = 0.63, p < 0.05), and the ICC(3,1) was good (ICC(3,1) = 0.76). Conclusions: The results showed that smartphones provide high validity and reliability as measurement equipment for JPS of dorsi-plantar flexion of the ankle. Finally, the study also considers that smartphone- based JPS measuring methods may replace the traditional and expensive methods that are currently being used for the same purpose.
Abstract
Objectives: This study evaluated and validated the reliability of smartphones as measuring equipment for the dorsi-plantar flexion of ankle joint position sense (JPS) ability. Methods: The subjects were 20 healthy young students in their 20s. We confirmed the concurrent validity by comparison with existing electrogoniometer data. The reliability of the smartphone was confirmed using the test-retest method. Results: In the case of dorsiflexion, there was no significant difference between the smartphone and electrogoniometer groups (p > 0.05). Regarding the correlation, it was significantly high (r = 0.65, p < 0.05), and ICC(3,1) was good (ICC(3,1) = 0.79). For the case of plantar flexion, there was no significant difference between the smartphone and electrogoniometer groups (p > 0.05), the correlation was significantly high (r = 0.69, p < 0.05), and the ICC(3,1) was very good (ICC(3,1) = 0.82). In the case of dorsiflexion, there was no significant difference between test and retest (p > 0.05), the correlation was intermediate (r = 0.59, p < 0.05), and the ICC(3,1) value was good (ICC(3,1) = 0.74). For plantar flexion, there was no significant difference between test and retest (p > 0.05), the correlation was significantly high (r = 0.63, p < 0.05), and the ICC(3,1) was good (ICC(3,1) = 0.76). Conclusions: The results showed that smartphones provide high validity and reliability as measurement equipment for JPS of dorsi-plantar flexion of the ankle. Finally, the study also considers that smartphone- based JPS measuring methods may replace the traditional and expensive methods that are currently being used for the same purpose.
참고문헌 (30)
- Gurney, B., "Role of fatigue on proprioception of the ankle", J Exerc Physiol, 3(1), pp.20~28 (2000)
- Goble DJ, "Where was my arm again? Memory-based matching of proprioceptive targets is enhanced by increased target presentation time", Neurosci Lett, 481(1), pp.54~58 (2010)
- Glencross D, "Position sense following joint injury", J Sports Med Phys Fitness, 21(1), pp.23~27 (1981)
- Moriguchi CS, "Ankle movements during normal gait evaluated by flexible electrogoniometer", Braz J Phys Ther, 11(3), pp.205~211 (2007)
- Garrick JG, "The epidemiology of foot and ankle injuries in sports", Clin Sports Med, 7(1), pp.29~36 (1988)
- Gehlson GM, "Ankle joint strength, total work, ROM: comparison between prophylactic devices", J Athl Train, 26(1), pp.62~65 (1991)
- Callaghan MJ., "What does proprioception testing tell us about patellofemoral pain?", Man Ther, 16(1), pp.46~47 (2011)
- 이정아, "팔굽관절에서 측정방법에 따른 고유수용성감각 차이", 한국전문물리치료학회지, 10(3), pp.63~70 (2003), 한국전문물리치료학회
- Roberts D, "Clinical measurements of proprioception, muscle strength and laxity in relation to function in the ACL-injured knee", Knee Surg Sports Traumatol Arthrosc, 15(1), pp.9~16 (2007)
- 황지선, "등속성 역량계를 이용한 편마비 환자의 슬관절 고유수용성 감각 평가", Annals of Rehabilitation Medicine, 34(1), pp.27~33 (2010), 대한재활의학회
- Bronner S, "Reliability and validity of electrogoniometry measurement of lower extremity movement", J Med Eng Technol, 34(3), pp.232~242 (2010)
- Mohammadi F, "Effects of fatigue due to contraction of evertor muscles on the ankle joint position sense in male soccer players", Am J Sports Med, 38(4), pp.824~828 (2010)
- Kwon OY, "Effects of muscle fatigue on knee proprioception", J Korean Acad Rehabil Med, 22(4), pp.960~965 (1998)
- 김명철, "스마트폰을 이용한 무릎관절 고유수용성 감각 측정의 타당도와 신뢰도 검증", 대한물리의학회지, 10(4), pp.15~23 (2015), 대한물리의학회
- Ferriero G, "Reliability of a smartphone-based goniometer for knee joint goniometry", Int J Rehabil Res, 36(2), pp.146~151 (2013)
- Jacquot F, "Measuring the Cobb angle with the iPhone in kyphoses : a reliability study", Int Orthop, 36(8), pp.1655~1660 (2012)
- Ozdalga E, "The smartphone in medicine: a review of current and potential use among physicians and students", J Med Internet Res, 14(5), pp.e128~ (2012)
- Boulos MN, "How smartphones are changing the face of mobile and participatory healthcare: an overview, with example from eCAALYX", Biomed Eng Online, 10, pp.24~ (2011)
- Lim JY, "Reliability of measuring the passive range of shoulder horizontal adduction using a smartphone in the supine versus the side-lying position", J Phys Ther Sci, 27(10), pp.3119~3122 (2015)
- Matsumura K, "iPhysioMeter : a new approach for measuring heart rate and normalized pulse volume using only a smartphone", Behav Res Methods, 45(4), pp.1272~1278 (2013)
- 한슬기, "스마트폰의 가속도 센서를 이용한 정적균형능력 측정의 신뢰도 연구", 한국산학기술학회논문지, 17(6), pp.233~238 (2016), 한국산학기술학회[DOI]
- Perlau R, "The effect of elastic bandages on human knee proprioception in the uninjured population", Am J Sports Med, 23(2), pp.251~255 (1995)
- Muraki T, "Lengthening of the pectoralis minor muscle during passive shoulder motions and stretching techniques : a cadaveric biomechanical study", Phys Ther, 89(4), pp.333~341 (2009)
- Borstad JD, "Resting position variables at the shoulder : evidence to support a posture-impairment association", Phys Ther, 86(4), pp.549~557 (2006)
- Franco PG, "Joint positioning sense, perceived force level and two-point discrimination tests of young and active elderly adults", Braz J Phys Ther, 19(4), pp.304~310 (2015)
- Hoon AH, "Sensory and motor deficits in children with cerebral palsy born preterm correlate with diffusion tensor imaging abnormalities in thalamocortical pathways", Dev Med Child Neurol, 51(9), pp.697~704 (2009)
- 이광재, "노인장기요양보험제도에서의 방문물리치료 도입에 대한 노인요양시설 물리치료사의 인식조사연구", 한국콘텐츠학회 논문지, 11(11), pp.231~240 (2011), 한국콘텐츠학회
- Rosa DP, "Reliability of measuring pectoralis minor muscle resting length in subjects with and without signs of shoulder impingement", Braz J Phys Ther, 20(2), pp.176~183 (2016)
- Relph N, "Criterion-related validity of knee joint-position-sense measurement using image capture and isokinetic dynamometry", J Sport Rehabil (2015)
- Vuillerme N, "Tongue-placed tactile biofeedback suppresses the deleterious effects of muscle fatigue on joint position sense at the ankle", Exp Brain Res, 183(2), pp.235~240 (2007)