CT 정도관리에서 ACR 팬텀을 이용한 딥러닝 모델 적용에 관한 연구
A Study on the Application of Deep Learning Model by Using ACR Phantom in CT Quality Control
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This study aimed to implement a deep learning model that can perform quantitative quality control through ACTS software used for quantitative evaluation of ACR phantom in CT quality control and evaluate its usefulness. By changing the scanning conditions, images of three modules of the ACR phantom's slice thickness (ST), low contrast resolution (LC), and high contrast resolution (HC) were obtained and classified as ACTS software. The deep learning model used ResNet18, implementing three models in which ST, HC, and LC were learned with epoch 50 and an integrated model in which three modules were learned with Epoch 10, 30, and 50 at once. The performance of each model was evaluated through Accuracy and Loss. When comparing and evaluating the accuracy and loss function values of the deep learning models by ST, LC, and HC modules, the Accuracy and Loss of the HC model were the best with 100% and 0.0081, and in the integrated model according to the Epoch value, Accuracy and Loss with epoch 50 were the best with 96.29% and 0.1856. This paper showed that quantitative quality control is possible through a deep learning model, and it can be used as a basis and evidence for applying deep learning to the CT quality control.
Abstract
This study aimed to implement a deep learning model that can perform quantitative quality control through ACTS software used for quantitative evaluation of ACR phantom in CT quality control and evaluate its usefulness. By changing the scanning conditions, images of three modules of the ACR phantom's slice thickness (ST), low contrast resolution (LC), and high contrast resolution (HC) were obtained and classified as ACTS software. The deep learning model used ResNet18, implementing three models in which ST, HC, and LC were learned with epoch 50 and an integrated model in which three modules were learned with Epoch 10, 30, and 50 at once. The performance of each model was evaluated through Accuracy and Loss. When comparing and evaluating the accuracy and loss function values of the deep learning models by ST, LC, and HC modules, the Accuracy and Loss of the HC model were the best with 100% and 0.0081, and in the integrated model according to the Epoch value, Accuracy and Loss with epoch 50 were the best with 96.29% and 0.1856. This paper showed that quantitative quality control is possible through a deep learning model, and it can be used as a basis and evidence for applying deep learning to the CT quality control.
참고문헌 (16)
- Lee KB, "Application of quantitative assessment method based on digital image processing technique for CT quality control", master, pp.2018
- 황호성, "CT 정도관리를 위한 인공지능 모델 적용에 관한 연구", 의공학회지, 44(3), pp.182~189 (2023), 대한의용생체공학회
- Kiss N, "Mushroom image classification with CNNs : A case-study of different learning strategies", International Symposium on Image and Signal Processing and Analysis(ISPA) (2021)
- Litjens G, "A survey on deep learning in medical image analysis", Medical Image Analysis, 42, pp.60~88 (2017)[DOI]
- Patro VM, "Augmenting weighted average with confusion matrix to enhance classification accuracy", Transactions on Machine Learning and Artificial Intelligence, 2(4), pp.77~91 (2014)[DOI]
- 강민제, "딥러닝을 위한 경사하강법 비교", 한국산학기술학회논문지, 21(2), pp.189~194 (2020), 한국산학기술학회[DOI]
- 조평곤, "컴퓨터단층촬영장치와 품질관리", 한국방사선학회논문지, 14(3), pp.221~233 (2020), 한국방사선학회[DOI]
- Chang KH, "Evaluation of the image quality on computed tomography with AAPM, ACR, catphan phantom", master, pp.2014
- Maritza A, "Using the ACR CT accreditation phantom for routine image quality assurance on both CT and CBCT imaging systems in a radiotherapy environment", Journal of Applied Clinical Medical Physics, 15(4), pp.226~239 (2014)[DOI]
- Mansour Z, "Quality control of CT image using American College of Radiology(ACR)phantom", The Egyptian Journal of Radiology and Nuclear Medicine, 47(4), pp.1665~1671 (2016)[DOI]
- Yoo MS, "The study of rationalization between dose and image quality using ACR phantom with abdominal computed tomography(CT)", master, pp.2018
- Kim JH, "Estimation of low contrast resolution in multi-detector CT : Comparison of CATPHAN, ACR phantom and AAPM phantom", Journal of Korean Society of Computed Tomographic Technology, pp.120~126 (2009)
- 이경성, "의료영상에서 단일 표적을 이용한 공간분해능 평가", 방사선기술과학, 39(4), pp.631~636 (2016), 대한방사선과학회[DOI]
- 장근조, "AAPM CT 성능 평가용 팬텀을 이용한 전산화단층촬영의영상 평가를 위한 정도관리 사례 연구", 한국콘텐츠학회 논문지, 7(7), pp.114~123 (2007), 한국콘텐츠학회
- 신석용, "딥러닝 기반의 Semantic Segmentation을 위한 Residual U-Net에 관한 연구", 디지털융복합연구, 19(6), pp.251~257 (2021), 한국디지털정책학회[DOI]
- Ying X, "An overview of overfitting and its solutions", Journal of Physics : Conference Series, 1168(2) (2019)[DOI]