본문 바로가기
KERD
논문KCI 등재

Comparative analysis of the clinical techniques used in evaluation of marginal accuracy of cast restoration using stereomicroscopy as gold standard

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

PURPOSE. This study assessed the effect of preparation design on marginal adaptation and also compared the sensitivity and specificity of clinical evaluation techniques for marginal accuracy of cast restorations to stereomicroscopy. MATERIALS AND METHODS. Three Ivorine molar teeth of different designs were prepared. (A)-A complete crown preparation with buccal shoulder and beveled finish line. (B)-A complete crown preparation with chamfer finish line. (C)-A three-quarter crown preparation with proximal boxes and beveled finish line. Twenty four castings were prepared with eight castings for each design respectively. Each casting underwent examination with an explorer, disclosing media, and a stereomicroscope. Stereomicroscopy at a value less than or equal to 30 microns was used as a gold standard to evaluate the significance of different designs on marginal adaptation. Chi-square tests of independence and Kruskal-Wallis were used to evaluate the effect of preparation design and compare the agreement between examination methods for detection of marginal gap size of greater than or equal to 30 microns (α=.05). Sensitivity and specificity for explorer and disclosing media as compared to stereomicroscope was calculated using statistical formula given by Park. RESULTS. The preparation design did not significantly affect overall marginal adaptation. Examination by explorer and disclosing media at 30 μm revealed 39% and 10.06% sensitivity and 91% and 82% specificity respectively. CONCLUSION. Preparation designs examined in this study did not significantly affect the marginal adaptation of the castings. Commonly used clinical evaluation techniques using explorer and disclosing media appeared to be inadequate for assessment of marginal accuracy.

Abstract

PURPOSE. This study assessed the effect of preparation design on marginal adaptation and also compared the sensitivity and specificity of clinical evaluation techniques for marginal accuracy of cast restorations to stereomicroscopy. MATERIALS AND METHODS. Three Ivorine molar teeth of different designs were prepared. (A)-A complete crown preparation with buccal shoulder and beveled finish line. (B)-A complete crown preparation with chamfer finish line. (C)-A three-quarter crown preparation with proximal boxes and beveled finish line. Twenty four castings were prepared with eight castings for each design respectively. Each casting underwent examination with an explorer, disclosing media, and a stereomicroscope. Stereomicroscopy at a value less than or equal to 30 microns was used as a gold standard to evaluate the significance of different designs on marginal adaptation. Chi-square tests of independence and Kruskal-Wallis were used to evaluate the effect of preparation design and compare the agreement between examination methods for detection of marginal gap size of greater than or equal to 30 microns (α=.05). Sensitivity and specificity for explorer and disclosing media as compared to stereomicroscope was calculated using statistical formula given by Park. RESULTS. The preparation design did not significantly affect overall marginal adaptation. Examination by explorer and disclosing media at 30 μm revealed 39% and 10.06% sensitivity and 91% and 82% specificity respectively. CONCLUSION. Preparation designs examined in this study did not significantly affect the marginal adaptation of the castings. Commonly used clinical evaluation techniques using explorer and disclosing media appeared to be inadequate for assessment of marginal accuracy.

참고문헌 (20)

  1. Felton DA, "Effect of in vivo crown margin discrepancies on periodontal health", J Prosthet Dent, 65, pp.357~364 (1991)
  2. Richter WA, "Relationship of crown margin placement to gingival inflammation", J Prosthet Dent, 30, pp.156~161 (1973)
  3. Preston JD, "Rational approach to tooth preparation for ceramo-metal restorations", Dent Clin North Am, 21, pp.638~698 (1977)
  4. Shillingburg HT Jr, "Preparation design and margin distortion in porcelain-fused-to-metal restorations", J Prosthet Dent, 29, pp.276~284 (1973)
  5. Rosner D, "Function, placement, and reproduction of bevels for gold castings", J Prosthet Dent, 13, pp.1160~1166 (1963)
  6. Syu JZ, "Influence of finish-line geometry on the fit of crowns", Int J Prosthodont, 6, pp.25~30 (1993)
  7. Rissin L, "Utilization of elastomeric materials to evaluate the accuracy of cast restorations prior to cementation", J Prosthet Dent, 49, pp.585~586 (1983)
  8. Davis SH, "Use of an elastomeric material to improve the occlusal seat and marginal seal of cast restorations", J Prosthet Dent, 62, pp.288~291 (1989)
  9. White SN, "Improved marginal seating of cast restorations using a silicone disclosing medium", Int J Prosthodont, 4, pp.323~326 (1991)
  10. Walker PM, "Remounting multiple casting prior to final cementation", J Prosthet Dent, 46, pp.145~148 (1981)
  11. McLean JW, "The estimation of cement film thickness by an in vivo technique", Br Dent J, 131, pp.107~111 (1971)
  12. Arakelian A Jr, "A technique for seating castings", J Prosthet Dent, 48, pp.357~ (1982)
  13. Eames WB, "Techniques to improve the seating of castings", J Am Dent Assoc, 96, pp.432~437 (1978)
  14. Belser UC, "Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study", J Prosthet Dent, 53, pp.24~29 (1985)
  15. Campagni WV, "Effect of die spacer on the seating of complete cast gold crowns with grooves", J Prosthet Dent, 55, pp.324~328 (1986)
  16. Fusayama T, "Technical procedure of precision casting", J Prosthet Dent, 9, pp.1037~1048 (1959)
  17. Pascoe DF, "Analysis of the geometry of finishing lines for full crown restorations", J Prosthet Dent, 40, pp.157~162 (1978)
  18. Christensen GJ, "Marginal fit of gold inlay castings", J Prosthet Dent, 16, pp.297~305 (1966)
  19. Jahangiri L, "Assessment of sensitivity and specificity of clinical evaluation of cast restoration marginal accuracy compared to stereomicroscopy", J Prosthet Dent, 93, pp.138~142 (2005)
  20. Park K, "Textbook of preventive and social medicine. 18th ed", pp.117~ (2005), Banarsidas Bhanot publishers

관련 논문AI추천

Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques윤미정, 전영찬, 정창모, 허중보대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제1호Effect of anatomic, semi-anatomic and non-anatomic occlusal surface tooth preparations on the adaptation of zirconia copingsMohammed Jameel Hefne, Syed Rashid Habib, Waleed Asiri대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제6호Evaluation and comparison of the marginal adaptation of two different substructure materialsAli Ihsan Zengingul, Ebru Sumer, Sabiha Zelal Ulku, Sedat Guven, Tahir Karaman, Veysel Eratilla대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제3호Comparison of three-dimensional digital technique with twodimensional replica method for measuring marginal and internal fit of full coverage restorationsMahya Hasanzade, Marzieh Alikhasi, Naeime Moslemian, Soudabeh Koulivand대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제3호Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography김동연, 김웅철, 김지환, 김총명, 김혜영대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제3호Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown박상원, 박지희, 오계정, 윤귀덕, 임현필, 지민경대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제4호

이 간행물의 다른 논문 (9건)