Errors in light-emitting diodes positioning when curing bulk fill and incremental composites: impact on properties after aging
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: This study aimed to evaluate the effect of improper positioning single-peak and multi-peak lights on color change, microhardness of bottom and top, and surface topography of bulk fill and incremental composites after artificial aging for 1 year. Materials and Methods: Bulk fill and incremental composites were cured using multi-peak and single-peak light-emitting diode (LED) following 4 clinical conditions: (1) optimal condition (no angulation or tip displacement), (2) tip-displacement (2 mm), (3) slight tip angulation (α = 20°) and (4) moderate tip angulation (α = 35°). After 1-year of water aging, the specimens were analyzed for color changes (ΔE), Vickers hardness, surface topography (Ra, Rt, and Rv), and scanning electron microscopy. Results: For samples cured by single-peak LED, the improper positioning significantly increases the color change compared to the optimal position regardless of the type of composite (p < 0.001). For multi-peak LED, the type of resin composite and the curing condition displayed a significant effect on ΔE (p < 0.001). For both LEDs, the Vickers hardness and bottom/top ratio of Vickers hardness were affected by the type of composite and the curing condition (p < 0.01). Conclusions: The bulk fill composite presented greater resistance to wear, higher color stability, and better microhardness than the incremental composite when subjected to improper curing. The multi-peak LED improves curing under improper conditions compared to single-peak LED. Prevention of errors when curing composites requires the attention of all personnel involved in the patient's care once the clinical relevance of the appropriate polymerization reflects on reliable long-term outcomes.
Abstract
Objectives: This study aimed to evaluate the effect of improper positioning single-peak and multi-peak lights on color change, microhardness of bottom and top, and surface topography of bulk fill and incremental composites after artificial aging for 1 year. Materials and Methods: Bulk fill and incremental composites were cured using multi-peak and single-peak light-emitting diode (LED) following 4 clinical conditions: (1) optimal condition (no angulation or tip displacement), (2) tip-displacement (2 mm), (3) slight tip angulation (α = 20°) and (4) moderate tip angulation (α = 35°). After 1-year of water aging, the specimens were analyzed for color changes (ΔE), Vickers hardness, surface topography (Ra, Rt, and Rv), and scanning electron microscopy. Results: For samples cured by single-peak LED, the improper positioning significantly increases the color change compared to the optimal position regardless of the type of composite (p < 0.001). For multi-peak LED, the type of resin composite and the curing condition displayed a significant effect on ΔE (p < 0.001). For both LEDs, the Vickers hardness and bottom/top ratio of Vickers hardness were affected by the type of composite and the curing condition (p < 0.01). Conclusions: The bulk fill composite presented greater resistance to wear, higher color stability, and better microhardness than the incremental composite when subjected to improper curing. The multi-peak LED improves curing under improper conditions compared to single-peak LED. Prevention of errors when curing composites requires the attention of all personnel involved in the patient's care once the clinical relevance of the appropriate polymerization reflects on reliable long-term outcomes.
참고문헌 (31)
- AlShaafi MM, "Factors affecting polymerization of resin-based composites: a literature review", Saudi Dent J, 29, pp.48~58 (2017)
- Price RB, "Light-curing units: a review of what we need to know", J Dent Res, 94, pp.1179~1186 (2015)
- de Oliveira DC, "Effect of nanofiller loading on cure efficiency and potential color change of model composites", J Esthet Restor Dent, 28, pp.171~177 (2016)
- Alrahlah A, "Post-cure depth of cure of bulk fill dental resin-composites", Dent Mater, 30, pp.149~154 (2014)
- Gan JK, "Bulk-fill composites: effectiveness of cure with poly- and monowave curing lights and modes", Oper Dent, 43, pp.136~143 (2018)
- Aggarwal N, "The comparative evaluation of depth of cure of bulk-fill composites - an in vitro study", J Conserv Dent, 22, pp.371~375 (2019)
- Van Ende A, "Bulk-filling of high C-factor posterior cavities: effect on adhesion to cavity-bottom dentin", Dent Mater, 29, pp.269~277 (2013)
- Flury S, "Depth of cure of resin composites: is the ISO 4049 method suitable for bulk fill materials?", Dent Mater, 28, pp.521~528 (2012)
- Azzopardi N, "Effect of resin matrix composition on the translucency of experimental dental composite resins", Dent Mater, 25, pp.1564~1568 (2009)
- Price RB, "The light-curing unit: an essential piece of dental equipment", Int Dent J, 70, pp.407~417 (2020)
- Derchi G, "Stiffness effect of using polywave or monowave LED units for photo-curing different bulk fill composites", Dent Mater J, 37, pp.709~716 (2018)
- Menees TS, "Depth of cure of bulk fill composites with monowave and polywave curing lights", Am J Dent, 28, pp.357~361 (2015)
- Maktabi H, "Factors influencing success of radiant exposure in light-curing posterior dental composite in the clinical setting", Am J Dent, 31, pp.320~328 (2018)
- Konerding KL, "Study of energy transfer by different light curing units into a class III restoration as a function of tilt angle and distance, using a MARC Patient Simulator (PS)", Dent Mater, 32, pp.676~686 (2016)
- Al-Zain AO, "Polymerization pattern characterization within a resin-based composite cured using different curing units at two distances", Clin Oral Investig, 23, pp.3995~4010 (2019)
- Eshmawi YT, "Variation in composite degree of conversion and microflexural strength for different curing lights and surface locations", J Am Dent Assoc, 149, pp.893~902 (2018)
- Janda R, "Color stability of resin-based filling materials after aging when cured with plasma or halogen light", Eur J Oral Sci, 113, pp.251~257 (2005)
- Maktabi H, "Underperforming light curing procedures trigger detrimental irradiance-dependent biofilm response on incrementally placed dental composites", J Dent, 88, pp.103110~ (2019)
- Meireles SS, "Validation and reliability of visual assessment with a shade guide for tooth-color classification", Oper Dent, 33, pp.121~126 (2008)
- Atai M, "The effect of a leucite-containing ceramic filler on the abrasive wear of dental composites", Dent Mater, 23, pp.1181~1187 (2007)
- Poggio C, "Evaluation of Vickers hardness and depth of cure of six composite resins photo-activated with different polymerization modes", J Conserv Dent, 15, pp.237~241 (2012)
- Balhaddad AA, "Concentration dependence of quaternary ammonium monomer on the design of high-performance bioactive composite for root caries restorations", Dent Mater, 36, pp.e266~e278 (2020)
- Sabatini C, "Color stability behavior of methacrylate-based resin composites polymerized with light-emitting diodes and quartz-tungsten-halogen", Oper Dent, 40, pp.271~281 (2015)
- Diamantopoulou S, "Change of optical properties of contemporary resin composites after one week and one month water ageing", J Dent, 41(Supplement 5), pp.e62~e69 (2013)
- Bendary IM, "Wollastonite as filler of an experimental dental adhesive", J Dent, 102, pp.103472~ (2020)
- Al-Zain AO, "The influence of distance on radiant exposure and degree of conversion using different light-emitting-diode curing units", Oper Dent, 44, pp.E133~E144 (2019)
- Ciccone-Nogueira JC, "Microhardness of composite resins at different depths varying the post-irradiation time", J Appl Oral Sci, 15, pp.305~309 (2007)
- de Camargo EJ, "Composite depth of cure using four polymerization techniques", J Appl Oral Sci, 17, pp.446~450 (2009)
- Moore BK, "Depth of cure of dental resin composites: ISO 4049 depth and microhardness of types of materials and shades", Oper Dent, 33, pp.408~412 (2008)
- Mitwalli H, "Emerging contact-killing antibacterial strategies for developing anti-biofilm dental polymeric restorative materials", Bioengineering (Basel), 7, pp.83~ (2020)
- Tantanuch S, "Surface roughness and erosion of nanohybrid and nanofilled resin composites after immersion in red and white wine", J Conserv Dent, 19, pp.51~55 (2016)
