초록

Background: As a restorative material used to treat dental caries, the light-curing type resin is widely used, but it has the disadvantage of polymerization shrinkage. The Bulk-Fill composite resin was developed to solve these shortcomings, but the existing research mainly focused on comparing the physical properties of a composite resin and a Bulk-Fill resin. A study on the light curing time and distance of the Bulk-Fill resin itself tend to be lacking.Methods: This study compares the surface microhardness of specimens prepared by varying the light curing time and distance of smart dentin replacement (SDR) as a flowable Bulk-Fill resin and Tetric N-ceram as a packable Bulk-Fill resin, and confirms the polymerization time and distance that becomes the optimum hardness. To determine the hardness of the specimen, it was measured using the Vickers Hardness Number (Matsuzawa MMT-X, Japan). Results: In SDR, the surface microhardness decreased as the distance increased in all time groups in the change distance from the curing tip. In the change of light curing time with respect to the distance from curing tip, the surface microhardness increased as the time increased. In Tetric N-ceram, the surface microharness showed no significant difference in the change of the distance of curing tip in the group of 20 and 60 second. But in the group of 10 and 40 seconds, decreased as the distance increased. The surface microharness increased as the light curing time increased in all distance groups. Conclusion: When using SDR and Tetric N-ceram in clinical practice, it is considered that as the distance from the polymerization reactor tip increases, a longer light curing time than the polymerization time recommended by the manufacturer is required.

Abstract

Background: As a restorative material used to treat dental caries, the light-curing type resin is widely used, but it has the disadvantage of polymerization shrinkage. The Bulk-Fill composite resin was developed to solve these shortcomings, but the existing research mainly focused on comparing the physical properties of a composite resin and a Bulk-Fill resin. A study on the light curing time and distance of the Bulk-Fill resin itself tend to be lacking.Methods: This study compares the surface microhardness of specimens prepared by varying the light curing time and distance of smart dentin replacement (SDR) as a flowable Bulk-Fill resin and Tetric N-ceram as a packable Bulk-Fill resin, and confirms the polymerization time and distance that becomes the optimum hardness. To determine the hardness of the specimen, it was measured using the Vickers Hardness Number (Matsuzawa MMT-X, Japan). Results: In SDR, the surface microhardness decreased as the distance increased in all time groups in the change distance from the curing tip. In the change of light curing time with respect to the distance from curing tip, the surface microhardness increased as the time increased. In Tetric N-ceram, the surface microharness showed no significant difference in the change of the distance of curing tip in the group of 20 and 60 second. But in the group of 10 and 40 seconds, decreased as the distance increased. The surface microharness increased as the light curing time increased in all distance groups. Conclusion: When using SDR and Tetric N-ceram in clinical practice, it is considered that as the distance from the polymerization reactor tip increases, a longer light curing time than the polymerization time recommended by the manufacturer is required.

참고문헌 (27)

  1. 정유진, "각각의 광조사기가 복합레진의 미세경도와 미세누출에 미치는 영향", Restorative Dentistry and Endodontics, 29(1), pp.58~65 (2004), 대한치과보존학회
  2. Park JK, "Polymerization shrinkage, flexural and compression properties of low-shrinkage dental resin composites", Dent Mater J, 33, pp.104~110 (2014)[DOI]
  3. 고결, "Bulk-fill 복합레진, 믿고 사용해도 될까?", 대한치과의사협회지, 57(3), pp.162~168 (2019), 대한치과의사협회[DOI]
  4. 노태환, "Comparison of the Mechanical Properties between Bulk-fill and Conventional Composites", 대한소아치과학회지, 43(4), pp.365~373 (2016), 대한소아치과학회[DOI]
  5. 김인영, "어린이 제 1 대구치 복합 레진 수복물의 5년 후 임상평가", 대한소아치과학회지, 35(1), pp.110~117 (2008), 대한소아치과학회
  6. Ilie N, "Investigations on a methacrylate-based flowable composite based on the SDR™ technology", Dent Mater, 27, pp.348~355 (2011)[DOI]
  7. Benetti AR, "Bulk-fill resin composites : polymerization contraction, depth of cure, and gap formation", Oper Dent, 40, pp.190~200 (2015)[DOI]
  8. 안명기, "광중합형 복합레진의 중합시간과 거리에 따른 중합도의 변화", 대한소아치과학회지, 28(2), pp.293~299 (2001), 대한소아치과학회
  9. Campos EA, "Marginal adaptation of class II cavities restored with bulk-fill composites", J Dent, 42, pp.575~581 (2014)[DOI]
  10. Van Ende A, "Bulk-fill composites : a review of the current literature", J Adhes Dent, 19, pp.95~109 (2017)[DOI]
  11. Leprince JG, "Physico-mechanical characteristics of commercially available bulk-fill composites", J Dent, 42, pp.993~1000 (2014)[DOI]
  12. 이한별, "Bulk-fill 복합레진의 상아질 전단결합강도 및 미세누출", 대한소아치과학회지, 42(4), pp.281~290 (2015), 대한소아치과학회[DOI]
  13. Alshali RZ, "Degree of conversion of bulk-fill compared to conventional resin-composites at two time intervals", Dent Mater, 29, pp.e213~e217 (2013)[DOI]
  14. Jang JH, "Polymerization shrinkage and depth of cure of bulk-fill resin composites and highly filled flowable resin", Oper Dent, 40, pp.172~180 (2015)[DOI]
  15. Aguiar FH, "Effect of light curing modes and light curing time on the microhardness of a hybrid composite resin", J Contemp Dent Pract, 8, pp.1~8 (2007)[DOI]
  16. 배상용, "광중합 시간과 거리의 변화에 따른 TheraCal LC의 중합도 평가", 대한소아치과학회지, 46(4), pp.392~399 (2019), 대한소아치과학회[DOI]
  17. Lim HN, "Studies on the developments of experimental restorative composite resins for dental caries and its compatibility to human tooth substrate", J Korean Res Soc Dent Mater, 19, pp.173~207 (1992)
  18. Knobloch L, "Hardness and degree of conversion of posterior packable composites", Oper Dent, 29, pp.642~649 (2004)
  19. Torno V, "Effects of irradiance, wavelength, and thermal emission of different light curing units on the Knoop and Vickers hardness of a composite resin", J Biomed Mater Res B Appl Biomater, 85, pp.166~171 (2008)[DOI]
  20. Kurachi C, "Hardness evaluation of a dental composite polymerized with experimental LED-based devices", Dent Mater, 17, pp.309~315 (2001)[DOI]
  21. 노유미, "Bulk-base 복합 레진의 중합 깊이에 따른 미세경도 평가", 대한소아치과학회지, 44(3), pp.335~340 (2017), 대한소아치과학회[DOI]
  22. 조수경, "치질을 투과한 조사광에 의한 복합레진 중합시 치질의 두께, 광세기 및 조사 시간이 복합레진의 표면 경도에 미치는 영향", Restorative Dentistry and Endodontics, 30(2), pp.128~137 (2005), 대한치과보존학회
  23. Joyti Lokade, "Morphological Measurements of Anatomic Landmarks in Human Mandibular Molar Pulp Chambers - An in vivo Study", Journal of Korean Dental Science, 4(1), pp.1~5 (2011), 대한치의학회
  24. Sohn MS:Development of shore and Vickers standard hardness block, "Hwang NM", Ministry of Science and ICT, 1~4 (1993)
  25. Diab R, "Impact of lightcuring distance on the effectiveness of cure of bulk-fill resin-based composites", Saudi Dent J, 33, pp.1184~1189 (2021)[DOI]
  26. Hasanain FA, "Effect of light curing distance on microhardness profiles of bulk-fill resin composites", Polymers, 14, pp.528~ (2022)[DOI]
  27. AlShaafi MM, "Effect of mold type and diameter on the depth of cure of three resin-based composites", Oper Dent, 43, pp.520~529 (2018)[DOI]

관련 논문AI추천

Effect of resin thickness on the microhardness and optical properties of bulk-fill resin composites허복, 권용훈, 김은하, 박정길, 손성애, 정경화대한치과보존학회 · Restorative Dentistry and Endodontics2015 · 제40권 제2호Physicochemical characterization of two bulk fill composites at different depthsCuevas-Suárez Carlos Enrique, Francia Alejandro, Grazioli Guillermo, Moraes Rafael Ratto de, Nakanishi Leina대한치과보존학회 · Restorative Dentistry and Endodontics2021 · 제46권 제3호Errors in light-emitting diodes positioning when curing bulk fill and incremental composites: impact on properties after agingAlkhubaizi Qoot, Balhaddad Abdulrahman A., Collares Fabrício M., Garcia Isadora M., Ibrahim Maria Salem, Maktabi Haifa, Melo Mary Anne S., Strassler Howard대한치과보존학회 · Restorative Dentistry and Endodontics2021 · 제46권 제4호Evaluation of marginal leakage of bulk fill flowable composite resin filling with different curing time using micro-computed tomography technology김은지, 이규복, 진명욱대한턱관절교합학회 · 구강회복응용과학지2016 · 제32권 제3호Bulk-fill과 Conventional 복합레진의 물성비교김기섭, 김종빈, 김종수, 석유정대한소아치과학회 · 대한소아치과학회지2016 · 제43권 제4호Difference in light transmittance and depth of cure of flowable composite depending on tooth thickness: an in vitro experimental study민경산, 유미경, 이광원, Bae Seong-Pyo, Lee Myung-Jin대한치과보존학회 · Restorative Dentistry and Endodontics2025 · 제50권 제4호

이 간행물의 다른 논문 (10건)